Quantifying 3D chemotaxis in microfluidic-based chips with step gradients of collagen hydrogel concentrations
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
In this work a microfluidic chip is proposed, consisting of three different channels for studying cell migration under chemical and mechanical gradients such as collagen concentrations of matrices and growth factors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By observing cell behavior in these devices, it was found that different types of cancer cells may react differently to the same chemical stimuli.”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [201]
Citations
Cites
Brown, R. A., Hastie, T. J., & Tibshirani, R. J. (1991) · Biometrics · doi:10.2307/2532174 · Cited by 8,176
Koyak, R. A., Hastie, T. J., & Tibshirani, R. J. (1991) · Journal of the American Statistical Association · doi:10.2307/2290538 · Cited by 7,596
Cell Movement Is Guided by the Rigidity of the Substrate
Lo, C.-M., Wang, H.-B., Dembo, M., & Wang, Y.-L. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76279-5 · Cited by 3,289
In vitro cell migration and invasion assays
Kramer, N., Walzl, A., Unger, C., Rosner, M., Krupitza, G., Hengstschläger, M., & Dolznig, H. (2013) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2012.08.001 · Cited by 1,170
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Platelet-derived growth factor in chemotactic for fibroblasts.
Seppä, H., Grotendorst, G., Seppä, S., Schiffmann, E., & Martin, G. R. (1982) · The Journal of cell biology · doi:10.1083/jcb.92.2.584 · Cited by 740
Collective cell durotaxis emerges from long-range intercellular force transmission
Sunyer, R., Conte, V., Escribano, J., Elosegui-Artola, A., Labernadie, A., Valon, L., Navajas, D., García-Aznar, J. M., Muñoz, J. J., Roca-Cusachs, P., et al. (2016) · Science · doi:10.1126/science.aaf7119 · Cited by 631
Self-citationMicrofluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels
Shin, Y., Han, S., Jeon, J. S., Yamamoto, K., Zervantonakis, I. K., Sudo, R., Kamm, R. D., & Chung, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.051 · Cited by 617
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Cell migration and invasion assays
Valster, A., Tran, N. L., Nakada, M., Berens, M. E., Chan, A. Y., & Symons, M. (2005) · Methods · doi:10.1016/j.ymeth.2005.08.001 · Cited by 317
Differential effects of EGF gradient profiles on MDA-MB-231 breast cancer cell chemotaxis
Wang, S.-J., Saadi, W., Lin, F., Minh-Canh Nguyen, C., & Li Jeon, N. (2004) · Experimental Cell Research · doi:10.1016/j.yexcr.2004.06.030 · Cited by 277
Fraley, S. I., Wu, P.-H., He, L., Feng, Y., Krisnamurthy, R., Longmore, G. D., & Wirtz, D. (2015) · Scientific Reports · doi:10.1038/srep14580 · Cited by 234
Elastic Moduli of Collagen Gels Can Be Predicted from Two-Dimensional Confocal Microscopy
Yang, Y.-L., Leone, L. M., & Kaufman, L. J. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.07.035 · Cited by 234
Miron-Mendoza, M., Seemann, J., & Grinnell, F. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.064 · Cited by 223
Effective neutrophil chemotaxis is strongly influenced by mean IL-8 concentration
Lin, F., Nguyen, C. M.-C., Wang, S., Saadi, W. M., Gross, S. P., & Jeon, N. L. (2004) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2004.05.029 · Cited by 157
The VEGF angiogenic switch of fibroblasts is regulated by MMP-7 from cancer cells
Ito, T.-K., Ishii, G., Chiba, H., & Ochiai, A. (2007) · Oncogene · doi:10.1038/sj.onc.1210535 · Cited by 146
Recent developments in microfluidics-based chemotaxis studies
Wu, J., Wu, X., & Lin, F. (2013) · Lab on a Chip · doi:10.1039/c3lc50415h · Cited by 138
Ensemble Analysis of Angiogenic Growth in Three-Dimensional Microfluidic Cell Cultures
Farahat, W. A., Wood, L. B., Zervantonakis, I. K., Schor, A., Ong, S., Neal, D., Kamm, R. D., & Asada, H. H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037333 · Cited by 113
Assays of leukocyte locomotion and chemotaxis
Wilkinson, P. C. (1998) · Journal of Immunological Methods · doi:10.1016/s0022-1759(98)00075-1 · Cited by 107
Directed cell migration in multi-cue environments
Rodriguez, L. L., & Schneider, I. C. (2013) · Integrative Biology · doi:10.1039/c3ib40137e · Cited by 106
Microfluidics for Mammalian Cell Chemotaxis
Kim, B. J., & Wu, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0489-9 · Cited by 96
Wax-bonding 3D microfluidic chips
Gong, X., Yi, X., Xiao, K., Li, S., Kodzius, R., Qin, J., & Wen, W. (2010) · Lab on a Chip · doi:10.1039/c004744a · Cited by 71
TheVGAMPackage for Capture-Recapture Data Using the Conditional Likelihood
Yee, T. W., Stoklosa, J., & Huggins, R. (2015) · Journal of Statistical Software · doi:10.18637/jss.v065.i05 · Cited by 61
Opioids and migration, chemotaxis, invasion, and adhesion of human cancer cells
Zagon, I. S., Rahn, K. A., & McLaughlin, P. J. (2007) · Neuropeptides · doi:10.1016/j.npep.2007.08.002 · Cited by 57
A rapid, multiwell colorimetric assay for chemotaxis
Shi, Y., Kornovski, B. S., Savani, R. C., & Turley, E. A. (1993) · Journal of Immunological Methods · doi:10.1016/0022-1759(93)90307-s · Cited by 54
Ouwehand, K., Spiekstra, S. W., Reinders, J., Scheper, R. J., de Gruijl, T. D., & Gibbs, S. (2009) · Toxicology in Vitro · doi:10.1016/j.tiv.2009.10.014 · Cited by 54
Analysis of the growth cone turning assay for studying axon guidance
Pujic, Z., Giacomantonio, C. E., Unni, D., Rosoff, W. J., & Goodhill, G. J. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.01.014 · Cited by 53
Fibroblast Migration in 3D is Controlled by Haptotaxis in a Non-muscle Myosin II-Dependent Manner
Moreno-Arotzena, O., Borau, C., Movilla, N., Vicente-Manzanares, M., & García-Aznar, J. M. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1343-2 · Cited by 51
Self-citationChemotaxis-driven assembly of endothelial barrier in a tumor-on-a-chip platform
Aung, A., Theprungsirikul, J., Lim, H. L., & Varghese, S. (2016) · Lab on a Chip · doi:10.1039/c6lc00184j · Cited by 50
Cinamon, G., & Alon, R. (2003) · Journal of Immunological Methods · doi:10.1016/s0022-1759(02)00418-0 · Cited by 49
Automated Chemotactic Sorting and Single-cell Cultivation of Microbes using Droplet Microfluidics
Dong, L., Chen, D., Liu, S., & Du, W. (2016) · Scientific Reports · doi:10.1038/srep24192 · Cited by 49
Feng, C.-H., Cheng, Y., & Chao, P. G. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.11.024 · Cited by 47
Microfluidics for in vitro biomimetic shear stress-dependent leukocyte adhesion assays
Bianchi, E., Molteni, R., Pardi, R., & Dubini, G. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.10.024 · Cited by 44
Improved rapid photometric assay for quantitative measurement of PMN migration
JUNGER, W. G., Cardoza, T. A., Liu, F. C., Hoyt, D. B., & Goodwin, R. (1993) · Journal of Immunological Methods · doi:10.1016/0022-1759(93)90010-5 · Cited by 43
A new chemotaxis device for cell migration studies
Raja, W. K., Gligorijevic, B., Wyckoff, J., Condeelis, J. S., & Castracane, J. (2010) · Integrative Biology · doi:10.1039/c0ib00044b · Cited by 42
A Novel Chemotaxis Assay in 3-D Collagen Gels by Time-Lapse Microscopy
Vasaturo, A., Caserta, S., Russo, I., Preziosi, V., Ciacci, C., & Guido, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052251 · Cited by 35
Jeong, H., Lee, S.-H., & Lee, C. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.03.031 · Cited by 33
Quantification of angiogenic sprouting under different growth factors in a microfluidic platform
Del Amo, C., Borau, C., Gutiérrez, R., Asín, J., & García-Aznar, J. M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.10.026 · Cited by 32
Self-citationMorel, M., Shynkar, V. V., Galas, J.-C., Dupin, I., Bouzigues, C., Studer, V., & Dahan, M. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.08.040 · Cited by 31
Moreno-Arotzena, O., Mendoza, G., Cóndor, M., Rüberg, T., & García-Aznar, J. M. (2014) · Biomicrofluidics · doi:10.1063/1.4903948 · Cited by 31
Self-citationA microfluidic Transwell to study chemotaxis
Zhang, C., Barrios, M. P., Alani, R. M., Cabodi, M., & Wong, J. Y. (2016) · Experimental Cell Research · doi:10.1016/j.yexcr.2016.03.010 · Cited by 31
Zhuang, L., Pound, J. D., Willems, J. J. L. P., Taylor, A. H., Forrester, L. M., & Gregory, C. D. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.06.008 · Cited by 30
Zen, K., Reaves, T. A., Soto, I., & Liu, Y. (2005) · Journal of Immunological Methods · doi:10.1016/j.jim.2005.11.014 · Cited by 29
Kuboki, T., Chen, W., & Kidoaki, S. (2014) · Langmuir · doi:10.1021/la501058j · Cited by 27
Dendritic cell migration assay: A potential prediction model for identification of contact allergens
Gibbs, S., Spiekstra, S. W., Corsini, E., McLeod, J., & Reinders, J. (2012) · Toxicology in Vitro · doi:10.1016/j.tiv.2012.05.016 · Cited by 27
Rees, B., Spiekstra, S. W., Carfì, M., Ouwehand, K., Williams, C. A., Corsini, E., McLeod, J., & Gibbs, S. (2011) · Toxicology in Vitro · doi:10.1016/j.tiv.2011.09.021 · Cited by 27
Computational model of mesenchymal migration in 3D under chemotaxis
Ribeiro, F. O., Gómez‐Benito, M. J., Folgado, J., Fernandes, P. R., & García‐Aznar, J. M. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1198784 · Cited by 27
Self-citationMicro-composite substrates for the study of cell-matrix mechanical interactions
Chao, P. G., Sheng, S.-C., & Chang, W.-R. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.01.008 · Cited by 24
Microfluidic switching system for analyzing chemotaxis responses of wortmannin-inhibited HL-60 cells
Liu, Y., Sai, J., Richmond, A. J., & Wikswo, J. P. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9158-z · Cited by 24
Hughes-Alford, S. K., & Lauffenburger, D. A. (2012) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2012.01.001 · Cited by 23
Assays for Eukaryotic Cell Chemotaxis
Pujic, Z., Mortimer, D., Feldner, J., & Goodhill, G. J. (2009) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/138620709788681952 · Cited by 23
A methodology to study chemotaxis in 3‐D collagen gels
Caserta, S., Campello, S., Tomaiuolo, G., Sabetta, L., & Guido, S. (2013) · AIChE Journal · doi:10.1002/aic.14164 · Cited by 17
Screening Assay for Promigratory/Antimigratory Compounds
Rust, W. L., Huff, J. L., & Plopper, G. E. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4510 · Cited by 16
A quantitative high-throughput chemotaxis assay using bioluminescent reporter cells
Vishwanath, R. P., Brown, C. E., Wagner, J. R., Meechoovet, H. B., Naranjo, A., Wright, C. L., Olivares, S., Qian, D., Cooper, L. J. N., & Jensen, M. C. (2005) · Journal of Immunological Methods · doi:10.1016/j.jim.2005.04.021 · Cited by 12
Microfluidic co-culture platform to quantify chemotaxis of primary stem cells
Tatárová, Z., Abbuehl, J.-P., Maerkl, S. J., & Huelsken, J. (2016) · Lab on a Chip · doi:10.1039/c6lc00236f · Cited by 12
Measuring Chemotaxis Using Direct Visualization Microscope Chambers
Muinonen‐Martin, A., Knecht, D. A., Veltman, D. M., Thomason, P. A., Kalna, G., & Insall, R. H. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-538-5_18 · Cited by 11
Visualizing Cancer Cell Chemotaxis and Invasion in 2D and 3D
Susanto, O., Muinonen‐Martin, A., Nobis, M., & Insall, R. H. (2016) · Methods in molecular biology · doi:10.1007/978-1-4939-3480-5_17 · Cited by 6
Axon Guidance Studies Using a Microfluidics-Based Chemotropic Gradient Generator
Pujic, Z., Nguyen, H., Glass, N. R., Cooper-White, J. J., & Goodhill, G. J. (2016) · Methods in molecular biology · doi:10.1007/978-1-4939-3480-5_20 · Cited by 3
Research works printed but not linked: 2
- Moreno-Arotzena, 2014, Biomicrofluidics, 8, 064122, 10.1063/1.4903948 · DOI · Paper page
- T. W. Yee , Springer Series in Statistics, Springer-Verlag New York, New York, USA, 2015, p.XXIV, 589
Cited by
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Microfluidics and hydrogel: A powerful combination
Goy, C. B., Chaile, R. E., & Madrid, R. E. (2019) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2019.104314 · Cited by 123
Combined experimental and computational characterization of crosslinked collagen-based hydrogels
Valero, C., Amaveda, H., Mora, M., & García-Aznar, J. M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0195820 · Cited by 90
“The hydrogels here characterized have been previously used to culture fibroblasts [45,46], osteoblasts [47] and endothelial cells (HUVEC) [44].”
BackgroundSelf-citationNasello, G., Alamán‐Díez, P., Schiavi, J., Pérez, M. Á., McNamara, L. M., & García‐Aznar, J. M. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00336 · Cited by 89
Self-citationOverview of Current Advances in Extrusion Bioprinting for Skin Applications
Perez‐Valle, A., Amo, C. D., & Andı́a, I. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186679 · Cited by 75
“Although pure collagen is successfully used in other novel 3D cell culture technologies, such as microfluidics [75,76], to meet the printability requirements, methods for rapid crosslinking while maintaining high cell viability need to be developed [3].”
Background
Metadata
- Authors
- Del Amo, C., Borau, C., Movilla, N., Asín, J., & García-Aznar, J. M.
- Affiliations
- Aragón Institute of Engineering Research (I3A)
- Universidad de Zaragoza (ES)
- Venue
- Integrative Biology
- Publisher
- Oxford University Press (OUP)
- Published
- 2017
- Volume
- 9
- Issue
- 4
- Pages
- 339-349
- ISSN
- 1757-9694 (ISSN-L)
- 1757-9708
- OpenAlex
- W2593200545
- Semantic Scholar
- 3cd5a9d494c4bcdf68dc7dc1a9e1ab6c0b90ff70
- Cited by
- 38
- References
- 58
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 8 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 8 · 2017: 2
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Integrative Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Research Council (ERC-2012-StG 306571)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- collagen gel, microfluidics, dermal fibroblasts, platelet-derived growth factor, vascular endothelial growth factor, chemoattractants, hydrogel microenvironment
- MeSH terms
- Cell Movement, Chemotaxis, Collagen, Fibroblasts, Humans, Image Processing, Computer-Assisted, Immune System, Platelet-Derived Growth Factor, Skin, Cell Culture Techniques, Hydrogels, Vascular Endothelial Growth Factor A, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.