Cited by 1163D Printing in Biomedical ResearchAnimal testing and alternativesTissue Engineering and Regenerative Medicine

Introduction to a manuscript series on the characterization and use of microphysiological systems (MPS) in pharmaceutical safety and ADME applications

Fabre, Kristin, Berridge, Brian, Proctor, William R., Ralston, Sherry, Will, Yvonne, Baran, Szczepan W., Yoder, Gorm, Van Vleet, Terry R.·2020·Lab on a Chip

Abstract

Opportunities in the drug discovery/development process for potential MPS incorporation.

Integrity signals

Registry

Crossref · 10.1039/c9lc01168d

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The IQ MPS affiliate has provided guidelines for qualifying new models for specific contexts of use to help advance regulatory acceptance and broader industrial adoption.

    “Recognizing the promise of MPS for drug research and development, the IQ MPS affiliate has provided guidelines for qualifying new models for specific contexts of use to help advance regulatory acceptance and broader industrial adoption18”
  • The IQ guidelines for assessment of an in vitro liver MPS within the DILI prediction context of use require evidence that the model replicates key histological structures and functions of the liver and can distinguish between 7 pairs of small-molecule toxic drugs and their non-toxic structural analogs; if it passes, it must demonstrate ability to predict the clinical responses of 6 additional-seed

    “The IQ guidelines for assessment of an in vitro liver MPS within the DILI prediction context of use requires evidence that the model replicates key histological structures and functions of the liver; furthermore, the model must be able to distinguish between 7 pairs of small-molecule toxic drugs and their non-toxic structural analogs. If the model passes through these hurdles, it must demonstrate”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fabre, K., Berridge, B., Proctor, W. R., Ralston, S., Will, Y., Baran, S. W., Yoder, G., & Van Vleet, T. R.
Affiliations
  • Translational Research Institute (AU)
  • National Institute of Environmental Health Sciences (US)
  • Genentech (US)
  • AbbVie (United States) (US)
  • Discovery, Product Development & Supply
  • Novartis (Switzerland) (CH)
  • Janssen Research & Development (United States) (US)
  • Department of Preclinical Safety
Venue
Lab on a Chip
Published
2020
Volume
20
Issue
6
Pages
1049-1057
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W3005321388
Cited by
116
References
9
Citations by year
2026: 14 · 2025: 17 · 2024: 23 · 2023: 18 · 2022: 18 · 2021: 23 · 2020: 3
FWCI
4.87
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
microphysiological systems, organotypic models, drug safety assessment, ADME, toxicology, organ-on-a-chip, biologics, drug disposition, animal-to-human translation
MeSH terms
Animals, Blood-Brain Barrier, Pharmaceutical Preparations, Humans, Kidney, Liver, Lung

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›