Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 326 of the 326 references it cites were found in a registry or an index.

A guide to the organ-on-a-chip

Open access
Leung, Chak Ming, de Haan, Pim, Ronaldson-Bouchard, Kacey, Kim, Ge-Ah, Ko, Jihoon, Rho, Hoon Suk, Chen, Zhu, Habibovic, Pamela, Jeon, Noo Li, Takayama, Shuichi, Shuler, Michael L., Vunjak-Novakovic, Gordana, Frey, Olivier, Verpoorte, Elisabeth, Toh, Yi-Chin·2022·Nature Reviews Methods Primers

Abstract

Organs-on-chips are microfluidic systems containing miniature tissues with the aim of mimicking human physiology for a range of biomedical and therapeutic applications. Leung, de Haan et al. report practical tips to inform design and operational decisions during the implementation of organ-on-a-chip systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s43586-022-00118-6

Cites

326 of 326 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 326 references

Research works printed but not linked: 8

  1. Ronaldson-Bouchard K., et al. Inter-organ chips with matured tissue niches linked by vascular perfusion. Nat. Biomed. Eng. (in the press). This paper reports a multi-tissue chip system in which matured human tissues are linked by recirculating vascular flow, allowing for the maintenance of their phenotypes, communication across endothelial barriers and recapitulation of interdependent organ functions.
  2. Kim, H. J., Li, H., Collins, J. J. & Ingber, D. E. Contributions of microbiome and mechanical deformation to intestinal bacterial overgrowth and inflammation in a human gut-on-a-chip. Proc. Natl Acad. Sci. USA 113, E7–E15 (2016).
  3. Vernetti, L. et al. Functional coupling of human microphysiology systems: intestine, liver, kidney proximal tubule, blood–brain barrier and skeletal muscle. Sci. Rep. 7, 42296 (2017). This paper combines multiple single-OoCs by manual transfer of culture medium from one organ to the next to simulate multi-organ functions; termed ‘functional’ coupling rather than direct coupling of organs in a flow-through system.
  4. Lindner, M., Laporte, A., Block, S., Elomaa, L. & Weinhart, M. Physiological shear stress enhances differentiation, mucus-formation and structural 3D organization of intestinal epithelial. Cell Vitro. Cell 10, 2062 (2021).
  5. Perlman, R. L. Mouse models of human disease: an evolutionary perspective. Evol. Med. Public Health 2016, 170–176 (2016).
  6. Liu, J., Pan, L., Cheng, X. & Berdichevsky, Y. Perfused drop microfluidic device for brain slice culture-based drug discovery. Biomed. Microdevices 18, 46 (2016).
  7. Wang, J. D. Development of a 3D in Vitro Model of the Blood–Brain Barrier in Layered Microfluidic Devices. PhD thesis, Univ. of Michigan (2015).
  8. Jeon, J.-W., Lee, S. H., Kim, D. & Sung, J. H. In vitro hepatic steatosis model based on gut–liver-on-a-chip. Biotechnol. Prog. 37, e3121 (2021).

Cited by

See all 1,116

Metadata

Authors
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., Shuler, M. L., Vunjak-Novakovic, G., Frey, O., Verpoorte, E., & Toh, Y.-C.
Affiliations
  • National University of Singapore (SG)
  • Columbia University (US)
  • Georgia Institute of Technology (US)
  • Seoul National University (KR)
  • Maastricht University (NL)
  • Bio-Rad (United States) (US)
  • Cornell University (US)
  • University of Groningen (NL)
  • Queensland University of Technology (AU)
Corresponding author
  • Takayama, Shuichi
  • Frey, Olivier
  • Toh, Yi-Chin
Venue
Nature Reviews Methods Primers
Published
2022-05-12
Volume
2
Issue
1
ISSN
2662-8449 (ISSN-L)
OpenAlex
W4280540675
Cited by
1,116
References
326
Citations by year
2026: 266 · 2025: 335 · 2024: 317 · 2023: 170 · 2022: 28
FWCI
18.95
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Reviews Methods Primers (publishedVersion, cc-by)
  • Research Publications (Maastricht University) (publishedVersion, cc-by)
  • QUT ePrints (Queensland University of Technology) (submittedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion, other-oa)
  • Research Publications (Maastricht University) (submittedVersion, other-oa)
Funders
  • National Science Foundation (1647837)
  • National Aeronautics and Space Administration (NNX16A069A)
  • National Research Foundation
  • National University of Singapore
  • National Research Foundation of Korea (2021R1A3B1077481)
  • National Institutes of Health (EB027062)
  • Biomedical Advanced Research and Development Authority
  • Australian Research Council (DP200101658, FT180100157)
  • National Heart, Lung, and Blood Institute (R01HL136414)
  • National Cancer Institute (R01CA249799)
  • National Institute of Biomedical Imaging and Bioengineering (P41EB027062)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
organ-on-a-chip, microfluidics, organoids, tissue engineering, microfluidic device design

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A guide to the organ-on-a-chip. https://app.cochat.ai/papers/10.1038/s43586-022-00118-6
The paper
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., Shuler, M. L., Vunjak-Novakovic, G., Frey, O., Verpoorte, E., & Toh, Y.-C. (2022). A guide to the organ-on-a-chip. Nature Reviews Methods Primers. https://doi.org/10.1038/s43586-022-00118-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.