A CO 2 -responsive hydrogel film for optical sensing of dissolved CO 2
Abstract
BPEI/PO-Dex LBL film swells in response of dissolved CO 2 and reports CO 2 level via the shift of Fabry–Perot fringes.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications such as NO2, NH3, CO2, and O2.
“Recent studies have reported the use of hydrogels as the sensitive material for gas-sensing applications, such as NO2, NH3, CO2, and O2”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [73]
Wang et al. [73] prepared hydrogel membranes from BPEI and PO-DEX by in situ Schiff base reaction to achieve rapid, real-time, and continuous monitoring of dissolved CO2.
“Wang et al. [73] prepared hydrogel membranes from branched polyethyleneimine (BPEI) and partially oxidized dextran (PO-DEX) by in situ Schiff base reaction to achieve rapid, real-time, and continuous monitoring of dissolved CO2.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [73]
The BPEI/PO-DEX films swell in water, and the swelling is greater when CO2 is introduced to react with the amino group in BPEI.
“The BPEI/PO-DEX films swell in water, and the swelling will be greater when CO2 is introduced to react with the amino group in BPEI.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [73]
The movement of the Fabry-Perot stripe on the reflectance spectrum of the BPEI/PO-DEX film is used as a sensing signal.
“The movement of the Fabry–Perot stripe on the reflectance spectrum of the BPEI/PO-DEX film is used as a sensing”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [73]
Cited by
Sorted by citations
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236 · see citing works
“[73] prepared hydrogel membranes from branched polyethyleneimine (BPEI) and partially oxidized dextran (PO-DEX) by in situ Schiff base reaction to achieve rapid, real-time, and continuous monitoring of dissolved CO2.”
Background
- Authors
- Wang, R., Zhang, M., Guan, Y., Chen, M., & Zhang, Y.
- Affiliations
- Nankai University (CN)
- China Academy of Engineering Physics (CN)
- Corresponding author
- Guan, Ying
- Chen, Mao
- Zhang, Yongjun
- Venue
- Soft Matter
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2019
- Volume
- 15
- Issue
- 30
- Pages
- 6107-6115
- ISSN
- 1744-683X (ISSN-L)
- 1744-6848
- OpenAlex
- W2955335692
- Cited by
- 21
- References
- 0
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 4 · 2022: 1 · 2021: 5 · 2020: 5
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Soft Matter (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (51625302, 51873091)
- Tianjin Science and Technology Committee (16JCZDJC32900)
- National Basic Research Program of China (2017YFC1103501)
- Topics
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Keywords
- hydrogel films, optical sensing, polyoxymethylene, Fabry-Perot fringes, swelling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review