CoChat

Development of a magnetic dispersive micro-solid-phase extraction method based on a deep eutectic solvent as a carrier for the rapid determination of meloxicam in biological samples

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

An environmentally friendly magnetic dispersive micro solid phase extraction based on a deep eutectic solvent as a carrier and disperser of adsorbents.

Overview

Integrity signals

Registry

Crossref · 10.1039/d0ay00095g

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 40

Metadata

Authors
Rastbood, S., Hadjmohammadi, M. R., & Majidi, S. M.
Affiliations
University of Mazandaran (IR)
Corresponding author
Hadjmohammadi, Mohammad Reza
Venue
Analytical Methods
Published
2020
Volume
12
Issue
18
Pages
2331-2337
ISSN
  • 1759-9660 (ISSN-L)
  • 1759-9679
OpenAlex
W3016183752
Cited by
40
References
29
Citations by year
2026: 5 · 2025: 6 · 2024: 7 · 2023: 6 · 2022: 9 · 2021: 6 · 2020: 1
FWCI
2.85
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Methods (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
Keywords
meloxicam, deep eutectic solvents, ferrofluids, silica-coated magnetic nanoparticles, preconcentration, biological specimen, urine, plasma, fractional factorial design, central composite design, extraction optimization
MeSH terms
Meloxicam, Blood Chemical Analysis, Silicon Dioxide, Solvents, Urinalysis, Solid Phase Extraction, Magnetic Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.