Quantitative design strategies for fine control of oxygen in microfluidic systems
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
We provide a generalized framework for creating fine control of O 2 tension in a microfluidic system and our data emphasize the need to consider mild spatiotemporal changes in O 2 as potentially important factors in disease processes such as cancer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the microfluidic system, the syringes were made of polypropylene which has low O2 permeability,26 and the Tygon® tubing has lower gas permeability compared to regular silicone tubing.”
From Retinal organoid chip: engineering a physiomimetic oxygen gradient for optimizing long term culture of human retinal organoids (2025) · cites this paper as [26]
Citations
Cites
1 retracted
Yoon, C., Chang, K. K., Lee, J. H., Tap, W. D., Hart, C. P., Simon, M. C., & Yoon, S. S. (2016) · Oncotarget · doi:10.18632/oncotarget.10212 · Cited by 22
RetractedHypoxia-inducible factors and the response to hypoxic stress
Majmundar, A. J., Wong, W. J., & Simon, M. C. (2010) · Molecular Cell · doi:10.1016/j.molcel.2010.09.022 · Cited by 2,380
Hypoxia in cancer: significance and impact on clinical outcome
Vaupel, P., & Mayer, A. (2007) · Cancer and Metastasis Reviews · doi:10.1007/s10555-007-9055-1 · Cited by 2,240
Hypoxia-inducible factors: mediators of cancer progression and targets for cancer therapy
Semenza, G. L. (2012) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2012.01.005 · Cited by 1,514
Jiang, B. H., Semenza, G. L., Bauer, C., & Marti, H. H. (1996) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1996.271.4.c1172 · Cited by 1,213
Hudson, C. C., Liu, M., Chiang, G. G., Otterness, D. M., Loomis, D. C., Kaper, F., Giaccia, A. J., & Abraham, R. T. (2002) · Molecular and Cellular Biology · doi:10.1128/mcb.22.20.7004-7014.2002 · Cited by 1,186
Gas sorption, diffusion, and permeation in poly(dimethylsiloxane)
Merkel, T. C., Bondar, V. I., Nagai, K., Freeman, B. D., & Pinnau, I. (2000) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/(sici)1099-0488(20000201)38:3<415::aid-polb8>3.0.co;2-z · Cited by 1,178
Vaupel, P. W., Schlenger, K., Knoop, C., & Höckel, M. (1991) · PubMed · Cited by 1,106
Reciprocal positive regulation of hypoxia-inducible factor 1alpha and insulin-like growth factor 2.
Feldser, D. M., Agani, F. H., Iyer, N. V., Pak, B. J., Ferreira, G., & Semenza, G. L. (1999) · PubMed · Cited by 801
Tumor hypoxia: causative factors, compensatory mechanisms, and cellular response
Vaupel, P., & Harrison, L. (2004) · The Oncologist · doi:10.1634/theoncologist.9-90005-4 · Cited by 761
Research works printed but not linked: 3
- Vaupel, 1991, Cancer Res., 51, 3316
- Granowitz, 2005, Anticancer Res., 25, 3833
- Feldser, 1999, Cancer Res., 59, 3915
Cited by
Tumor-on-chip modeling of organ-specific cancer and metastasis
Del Piccolo, N., Shirure, V. S., Bi, Y., Goedegebuure, S. P., Gholami, S., Hughes, C. C. W., Fields, R. C., & George, S. C. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.008 · Cited by 126
“We used the platform to study the effects of hypoxia on the BC cell line MDA-MB-231 [78].”
BackgroundMethodSelf-citationImmunocompetent cancer-on-chip models to assess immuno-oncology therapy
Maulana, T. I., Kromidas, E., Wallstabe, L., Cipriano, M., Alb, M., Zaupa, C., Hudecek, M., Fogal, B., & Loskill, P. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.03.015 · Cited by 93
Simitian, G. S., Virumbrales-Muñoz, M., Sánchez‐de‐Diego, C., Beebe, D. J., & Kosoff, D. (2022) · Lab on a Chip · doi:10.1039/d2lc00352j · Cited by 56
Micro-engineering and nano-engineering approaches to investigate tumour ecosystems
Kim, M., Panagiotakopoulou, M., Chen, C., Ruiz, S. B., Ganesh, K., Tammela, T., & Heller, D. A. (2023) · Nature reviews. Cancer · doi:10.1038/s41568-023-00593-3 · Cited by 57
Myers, D. R., & Lam, W. A. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-091520-025358 · Cited by 51
Cancer-on-a-chip for precision cancer medicine
Liu, L., Wang, H., Chen, R., Song, Y., Wei, W., Baek, D. S. H., Gillin, M., Kurabayashi, K., & Chen, W. (2025) · Lab on a Chip · doi:10.1039/d4lc01043d · Cited by 52
Bender, R. H. F., O’Donnell, B. T., Shergill, B. S., Pham, B. Q., Tahmouresie, S., Sanchez, C. N., Juat, D. J., Hatch, M. M. S., Shirure, V. S., Wortham, M., et al. (2023) · Biofabrication · doi:10.1088/1758-5090/ad17d0 · Cited by 49
“The PDMS was permeable to oxygen and media entering the device was in equilibrium with the atmospheric oxygen [32].”
Self-citationWang, J., Li, T. Y., Wang, R., Han, C., Xu, S., You, T., Li, Y., Xia, J., Xu, X., Wang, D., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c06337 · Cited by 41
Advances in Modeling the Immune Microenvironment of Colorectal Cancer
Yoon, P., Piccolo, N. D., Shirure, V. S., Peng, Y., Kirane, A., Canter, R. J., Fields, R. C., George, S. C., & Gholami, S. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2020.614300 · Cited by 35
Self-citationDrabbe, E., Pelaez, D., & Agarwal, A. (2025) · Lab on a Chip · doi:10.1039/d4lc00771a · Cited by 26
Diversity Models and Applications of 3D Breast Tumor-on-a-Chip
Song, K., Zu, X., Du, Z., Hu, Z., Wang, J., & Li, J. (2021) · Micromachines · doi:10.3390/mi12070814 · Cited by 22
“hypoxia model simulates the hypoxia microenvironment around the tumor in body, diversified methods, controllable difficult to prepare, severely affected by airtightness and matrix permeability [74,80,81]”
BackgroundMethodPrecise and fast control of the dissolved oxygen level for tumor-on-chip
Bouquerel, C., César, W., Barthod, L., Arrak, S., Battistella, A., Gropplero, G., Mechta‐Grigoriou, F., Zalcman, G., Parrini, M. C., Verhulsel, M., et al. (2022) · Lab on a Chip · doi:10.1039/d2lc00696k · Cited by 22
Plesselova, S., Calar, K., Axemaker, H., Sahly, E., Bhagia, A., Faragher, J. L., Fink, D. M., & de la Puente, P. (2024) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-024-00817-y · Cited by 21
“…model to recreate a hypoxic tumor microenvironment that induced higher tumor growth and migration of breast cancer cells, however, they generated hypoxia by injecting sodium sulfide [48], meanwhile, our design was bioengineered to recreate the hypoxic TME without the need for external agents.”
Gaebler, D., Hachey, S. J., & Hughes, C. C. W. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1462293 · Cited by 22
3D Bioprinting for Tumor Metastasis Research
Lin, M., Tang, M., Duan, W., Xia, S., Liu, W., & Wang, Q. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c00239 · Cited by 20
96-Well Oxygen Control Using a 3D-Printed Device
Szmelter, A., Jacob, J., & Eddington, D. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04627 · Cited by 14
A More Biomimetic Cell Migration Assay with High Reliability and Its Applications
Yin, D., Zhang, H., Yang, C., Zhang, W., & Yang, S. (2022) · Pharmaceuticals · doi:10.3390/ph15060695 · Cited by 11
“Cell migration refers to the movement of cells from one location to another under various stimuli, including shear stress [1], topography [2], oxygen [3], cytokines [4], and extracellular matrix proteins [5]; it is considered as one of the important indicators of the physiological and pathological process, e.”
BackgroundRadonjić, M., Petrović, J., Milivojević, M., Stevanović, M. J., Stojkovska, J., & Obradović, B. (2021) · Chemical Industry and Chemical Engineering Quarterly · doi:10.2298/ciceq210607033r · Cited by 5
Salvinia-inspired architectures for enhancing interface stability and mass transfer in microchannels
Xu, J., Li, Y., & Chen, H. (2025) · Lab on a Chip · doi:10.1039/d5lc00599j · Cited by 3
Fu, W., Wang, S., Ouyang, Q., & Luo, C. (2024) · Integrative Biology · doi:10.1093/intbio/zyae011 · Cited by 3
OSTE microfluidics: Fabrication and applications
Guo, W., Xiao, Z., Feng, Z., Zhong, J., Ye, Z., Zhou, J., Chen, D., He, Q., Chen, H., Wu, G., et al. (2026) · Materials Today Communications · doi:10.1016/j.mtcomm.2026.115457 · Cited by 1
Maia, R. P. F. (2022) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/nd4d-r549 · Cited by 1
A Hypoxia-Maintaining Perfusion Device for Prolonged Cell Studies
Ameziane, K. (2024) · Tampere University Institutional Repository (Tampere University) · Cited by 1
Rando, A. M. A., Poppa, M., Russo, C., Fiore, G. B., & Soncini, M. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.04.13.718107
Metadata
- Authors
- Shirure, V. S., Lam, S. F., Shergill, B., Chu, Y. E., Ng, N. R., & George, S. C.
- Affiliations
- University of California, Davis (US)
- Washington University in St. Louis (US)
- Corresponding author
- George, Steven C.
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2020
- Volume
- 20
- Issue
- 16
- Pages
- 3036-3050
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W3042432421
- Cited by
- 21
- References
- 32
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2023: 2 · 2022: 4 · 2021: 8
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (R01 CA170879, UC4 DK104202, UH3 TR00048)
- National Science Foundation (DGE-1143954)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer, Hypoxia, and Metabolism
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- hypoxia, microfluidic device design, sodium sulfite, oxygen reduction reaction, mass transfer, reaction kinetics, dimensionless parameters, phosphorescence lifetime imaging, hypoxia-inducible factor-1α, breast cancer cells, MDA-MB-231 cells, cell proliferation, cell migration, oxygen fluctuations
- MeSH terms
- Hypoxia, Humans, Oxygen, Cell Hypoxia, Cell Culture Techniques, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.