Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry
Open accessThe DOI matches its Crossref record; 179 of the 179 references it cites were found in a registry or an index; 18 of the 71 sources its claims cite were checked for support.
Abstract
Top-down mass spectrometry techniques break up native proteins and complexes to reveal all levels of structural information.
Overview
CoChat Summary
TL;DR
This review describes how native mass spectrometry combined with top-down fragmentation can characterize higher-order structure of proteins and complexes, including subunit connectivity, ligand/metal binding, and secondary/tertiary structure. It surveys complex-up, complex-down, and native top-down workflows and highlights remaining technical and data-analysis challenges.
Key findings
- Native MS alone gives mass and stoichiometry but limited connectivity; complex-up activation by CID/SID can dissect complexes. SID better preserves subunit connectivity, as in Mnx (MnxE 12.2 kDa, MnxF 11.2 kDa, MnxG 138 kDa), assigned as MnxE3F3G, whereas CID showed mostly monomer stripping.
- Complex-down MSn ejects monomers or ligands from native complexes and then sequences them; examples include GroEL 14-mer (801 kDa), AaLS virus-like nanocontainer (>1 MDa), and an E. coli lysate separation identifying 672 proteoforms and 23 protein complexes.
- Native top-down with ExD/UVPD fragments intact native proteins and complexes in conformation-sensitive ways, probing secondary/tertiary structure, ligand/metal sites, and interfaces; ADH tetramer showed N-terminal unfolding followed by partial refolding with increasing activation, and UVPD a/a+1 ratios report secondary structure.
- The review concludes that combining native ionisation, top-down fragmentation, and native separations enables structural information from subunit connectivity to secondary/tertiary structure, but software, manual analysis, SID availability, and expertise remain limiting.
Methods
- Narrative review, not primary research; it synthesizes published literature on native MS and top-down MS.
- No experimental sample, dataset, or statistical analysis is reported; cited examples span soluble and membrane protein complexes, heterogeneous mixtures, and model systems.
- Main analysis is a conceptual and technical synthesis of activation methods (CID, SID, ExD, UVPD, IRMPD) and workflows (complex-up, complex-down, native TD).
Limitations
- Stated: technical challenges remain; data analysis is a bottleneck because native MS spectra often lack isotopic resolution and complex-down/TDMS often require manual analysis or validation; SID availability is limited; sophisticated equipment and expertise have restricted the field.
- Stated: the degree of gas-phase “nativeness” is controversial, and excessive activation can cause structural rearrangement, so care is needed to minimize unfolding.
- Evident: as a narrative review, it does not perform a systematic search or quantitative meta-analysis, and examples are selected to illustrate methods rather than to estimate performance.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures






![Fig. 6 (a) ECD fragmentation map of the 7+ amylin dimer. The critical [M + c29] and [M + z3˙] fragments, shown in (b), are indicated by a black, dashed circle in this map. Panel (c) shows the proposed staggered structure of the oligomers. Adapted with permission from ref. 167. Copyright 2020 American Chemical Society.](https://figures.cochat.ai/paper-figures/f8735fbe917c42c9b73fe089738641d6/higher-order-structural-characterisation-of-native-proteins-and-complexes-by-top-figure-6.jpg)









Verification
Claims the paper makes
13 Valid · 4 Not valid · 38 Not checked · 38 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“In addition to mass alone, the 3D shape of proteins and complexes can be simultaneously investigated by ion mobility-mass spectrometry (IM-MS).”
§ Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry > Introduction and historical perspective > Native mass spectrometry of protein complexes
What the sources say
- Supportedcites [23] source
The Introduction describes IM-MS as a tool for structural characterization and explicitly includes proteins and biomolecular complexes among its applications. It also explains that ion-mobility measurements can be related to structural models, supporting the claim that shape can be investigated alongside mass. (LLM, conf=0.90)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The ejected ion – monomer or ligand – is subsequently (re-)isolated and fragmented in a (pseudo-)MS3 or MS4 workflow, providing in-depth information on e.g., phosphorylation sites,104 metal ion binding,36 or sequencing of peptide ligands (see Fig. 3).105”
§ Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry > Gas-phase activation of intact, native proteins and complexes > Sequencing of ejected proteins from native complexes (‘complex-down’ approach)
What the sources say
- Could not verifycites [104] sourceExperimental — accuracy not yet measured
The Results and Discussion passage on MS3 describes isolating and fragmenting FBP1 subunits to identify their sequence and map phosphorylation sites. Citation 105 is attached to sequencing peptide ligands, but the passages found when searching for peptide-ligand sequencing describe fragments of FBP1, not ejected peptide ligands or an MS4 workflow. (LLM, conf=0.73)
- Supportedcites [36] source
The citation is attached to metal ion binding. In Results > Characterization of Endogenous Metalloenzymes (page unavailable), the paper reports metal binding on protein complexes and ejected monomers, including partial localization of zinc binding by tandem MS. Online Methods > Native Top-Down MS analysis describes isolating and fragmenting an ejected monomer in an MS3 workflow. (LLM, conf=0.91)
- Supportedcites [105] source
Citation 105 is attached to sequencing of peptide ligands, not to phosphorylation-site or metal-binding analysis. In Results and Discussion (Native Top-Down MS), the paper describes releasing peptides from intact KLHDC2:peptide complexes, isolating the released ions, and fragmenting them to determine their sequences; the following section calls these native MS3 experiments. Page numbers are not provided in our copy. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“It was found that optimal collisional cooling and trapping before UVPD fragmentation allowed for efficient detection of intact virus nanocontainers, monomers, and sequence fragments.”
§ Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry > Gas-phase activation of intact, native proteins and complexes > Sequencing of ejected proteins from native complexes (‘complex-down’ approach)
What the sources say
- Supportedcites [107] source
The Results and discussion (p. 2, '## Results and discussion') states that detectability of UVPD fragments from large protein complexes was improved by reducing the ions' kinetic energy before the HCD cell (Source DC Offset lowered to 2–5 V explicitly 'for MDa wt-AaLS particles') and by adjusting the trapping conditions, with trapping of precursor ions under low pressure 'thereby enhancing detection of the fragments', and 'Optimal detection was observed using low pressure nitrogen as trapping gas'. The AaLS section (Fig. 4 and the accompanying text) shows the outcome of those settings: detection of the intact >1 MDa wt-AaLS virus-like nanocontainer precursor ions, intact monomeric subunits, and, at higher fluence, top-down peptidic (sequence) fragments. The claim is a faithful paraphrase of these two linked statements. (LLM, conf=0.88)
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Subsequent electron microscopy (EM) imaging then demonstrated preservation of native-like structures throughout the process of ionisation, dehydration, and soft-landing.”
§ Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry > Introduction and historical perspective > Native mass spectrometry of protein complexes
What the sources say
- Not checked yetcites [27] source
- Supportedcites [28] source
The Results (p. 9) state that the agreement between the low-energy electron micrographs and the atomic model 'clearly demonstrates that proteins can be found in UHV in structures closely related to their native structure', and the Results (p. 7) present the complete soft-landing and imaging data set for CytC, whose mass-selected beam shows 'the characteristically low charge states corresponding to the protein in its folded state'. The Introduction (p. 4) adds that ions generated by electrospray ionization and mass filtering are decelerated to 2-5 eV per charge, 'which ensures retention of the native state upon deposition', and the Abstract (p. 2) credits soft-landing ESI beam deposition with conformational-specific selection and gentle deposition. The source's workflow therefore spans ionisation (including the desolvation inherent to electrospray, evidenced by the folded-state charge distribution) through deposition, with the electron-microscopic imaging confirming native-like structure at the end; the citing sentence's explicit 'dehydration' step is the paper's electrospray desolvation rather than a separate experiment, but nothing in the attributed content is unstated by the source. (LLM, conf=0.82)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Efficient sequencing can be combined with obtaining information on noncovalent complex stoichiometry through MSn (n = 3 or more) analysis of complexes ionised under non-denaturing conditions.”
§ Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry > Gas-phase activation of intact, native proteins and complexes > Sequencing of ejected proteins from native complexes (‘complex-down’ approach)
What the sources say
- Supportedcites [17] source
The Complex-Down section (page not provided) describes obtaining sequence information and noncovalent-complex stoichiometry together. It specifies native electrospray ionization and an MS3-type experiment in which an ejected monomer is isolated and further fragmented. (LLM, conf=0.89)
- Partly supportedcites [103] sourceExperimental — accuracy not yet measured
The paper reports that native multistage MS retained three peptide-binding sites on an OmpF complex and that subsequent pMS4 fragmentation yielded ions used to assign the bound peptide’s sequence (Abstract). This supports combining information about a noncovalent complex with sequence identification. It does not establish efficient sequencing generally; the Extended Data describe the top-down experiment as not fully optimised and say sequence coverage could be improved. (LLM, conf=0.82)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
47 more claims · 5 with their cited sources checked
Create a free account to see all 93 claims and to verify the 53 references still open.
- It may state two separate claims as one. 25
- Probably not a substantial claim. 20
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Briefly, native top-down MS involves using non-denaturing conditions and often employing 100–200 mM ammonium acetate as a volatile buffer for the analysis of intact proteins and protein complexes.”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [41]
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Proteoform: a single term describing protein complexity
The Consortium for Top Down Proteomics, Smith, L. M., & Kelleher, N. L. (2013) · Nature Methods · doi:10.1038/nmeth.2369 · Cited by 1,528
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Research works printed but not linked: 1
- Zhang, 2011, Anal. Chem., 83, 5598, 10.1021/ac200695d · DOI · Paper page
Cited by
Items 101–146 of 146
Nagy, C., Lieu, L. B., Mullen, C., McAlister, G. C., Melani, R. D., Hinkle, J. D., & Fornelli, L. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00385 · Cited by 4
Deconvolving Native and Intact Protein Mass Spectra with UniDecPreprint
Kostelic, M. M., & Marty, M. T. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13417118.v1 · Cited by 4
“[711] The combination of native MS with top-down provides a powerful tool for the simultaneous characterization of covalent and noncovalent protein interactions.[12-14] For all of these techniques, the initial spectrum of the intact protein has multiple charge states that must be assigned to determine the mass.”
BackgroundSadighi, R., van Paasen, R. M. A., Hutchins, G. H., Jansen, I. D., Neubacher, S., Grossmann, T. N., & Rijs, A. M. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c06844 · Cited by 2
Zhou, S., Yang, X., Zhang, M., Ji, P., Zhong, F., Pan, Y., & Zhou, M. (2026) · Journal of Mass Spectrometry · doi:10.1002/jms.70006 · Cited by 3
Self-citationIon Activation Methods for Top‐Down Proteomics
Walker, J. N., & Brodbelt, J. S. (2026) · Mass Spectrometry Reviews · doi:10.1002/mas.70023 · Cited by 5
New Insights into the Intrinsic Electron-Based Dissociation Behavior of Cytochrome c Oligomers
Brandner, S., Habeck, T., & Lermyte, F. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00106 · Cited by 2
Self-citationYing, Y., & Li, H. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341971 · Cited by 2
Reid, D. J., Thibert, S. M., Wilson, J., Soldatova, A. V., Tebo, B. M., Spiro, T. G., & Zhou, M. (2023) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2023.117172 · Cited by 1
“[7, 22, 31, 32] In addition to new advances in MS technology, our data also show how sample preparation such as buffer composition can impact measured metal binding.”
BackgroundMethodSelf-citationLee, A. S., Fisher, N. P., Marunde, M. R., Su, P., Khan, L. F., Ezell, R. J., Gillespie, Z. B., Graham, B., Taylor, H. F., Onuoha, U. C., et al. (2026) · ACS Central Science · doi:10.1021/acscentsci.5c00736 · Cited by 4
Soft Ionization Mass Spectrometry for Studying Noncovalent Interactions
Zenobi, R. (2022) · CHIMIA International Journal for Chemistry · doi:10.2533/chimia.2022.101 · Cited by 3
A novel method for photon unfolding spectroscopy of protein ions in the gas phase
Zhou, M., Jiao, L., Xu, S., Xu, Y., Du, M., Zhang, X., & Kong, X. (2022) · Review of Scientific Instruments · doi:10.1063/5.0080040 · Cited by 2
Self-citationComputational biology for enzymatic removal of mycotoxinsPreprint
Sandlin, N., Kish, D. R., Kim, J., Zaccaria, M., & Momeni, B. (2021) · OSF Preprints (OSF Preprints) · doi:10.31219/osf.io/9f4an · Cited by 3
Native mass spectrometry reveals binding interactions of SARS-CoV-2 PLpro with inhibitors and ISG15Preprint
James, V. K., Godula, R., Perez, J., Butalewicz, J. P., Sipe, S. N., Huibregtse, J. M., & Brodbelt, J. S. (2023) · ChemRxiv · doi:10.26434/chemrxiv-2023-v6j35 · Cited by 2
Adapting a trapped ion mobility spectrometry-Q-TOF mass spectrometer for native mass spectrometryPreprint
Lin, Y.-F., Jones, B., Ridgeway, M. E., Panczyk, E. M., Somogyi, Á., Kaplan, D. A., Marathe, I. A., Yun, S., Laganowsky, A. D., Park, M. A., et al. (2024) · ChemRxiv · doi:10.26434/chemrxiv-2024-xmjml-v2 · Cited by 2
Membrane Proteins: Challenging Biotherapeutic Targets
Jayasekera, H. S., Mohona, F. A., & Marty, M. T. (2025) · Wiley eBooks · doi:10.1002/9781394236145.ch18 · Cited by 2
Mass spectrometry structural analysis of intrinsically disordered phosphoproteins
Lantz, C., Zenaidee, M. A., Tran, D. P., Biggs, K. E., Bitan, G., Loo, R. R. O., & Loo, J. A. (2025) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2025.117455 · Cited by 1
Self-citationOney-Hawthorne, S. D., Barondeau, D. P., & Russell, D. H. (2025) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00280 · Cited by 1
Top‐Down Mass Spectrometry–Based Structural and Functional Proteomics: A Perspective
Cupp‐Sutton, K. A., & Wu, S. (2026) · Journal of Mass Spectrometry · doi:10.1002/jms.70044 · Cited by 2
Beaumal, C., Srzentić, K., Carillo, S., & Bones, J. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00438 · Cited by 1
Shoff, T. A., & Julian, R. R. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00196 · Cited by 1
The need for open and FAIR data in top‐down proteomics
Lermyte, F. (2023) · PROTEOMICS · doi:10.1002/pmic.202300354 · Cited by 2
“The vast improvements in both hardware and software in recent years have led toanever-increasingnumberofstudiesapplyingtop-downMStostudy both primary and higher-order protein structure [13, 14].”
BackgroundSelf-citationMicroscale measurements of protein complexes from single cells
Dutta, T., & Vlassakis, J. (2024) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2024.102860 · Cited by 1
Fe-S cluster biosynthesis and maturation: Mass spectrometry-based methods advancing the field
Oney-Hawthorne, S. D., & Barondeau, D. P. (2024) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2024.119784 · Cited by 1
Characterization of Gas-Phase Native(-like) Proteins Using Structures for Lossless Ion Manipulations
Lee, J. Y., Gandhi, V., Harrilal, C., Parvate, A. D., Ives, A. N., Bhotika, H., Thibert, S. M., Zhang, X., Schenter, G. K., Larriba‐Andaluz, C., et al. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c02054 · Cited by 2
Deconvolving Native and Intact Protein Mass Spectra with UniDecPreprint
Kostelic, M. M., & Marty, M. T. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13417118 · Cited by 2
Adapting a trapped ion mobility spectrometry-Q-TOF for native mass spectrometryPreprint
Lin, Y.-F., Jones, B., Ridgeway, M. E., Panczyk, E. M., Somogyi, Á., Kaplan, D. A., Marathe, I. A., Yun, S., Laganowsky, A. D., Park, M. A., et al. (2024) · ChemRxiv · doi:10.26434/chemrxiv-2024-xmjml · Cited by 1
Membrane Proteins: Challenging Biotherapeutic TargetsPreprint
Jayasekera, H. S., Mohona, F. A., & Marty, M. T. (2024) · ChemRxiv · doi:10.26434/chemrxiv-2024-dz7rf · Cited by 1
X-ray Spectroscopy Meets Native Mass Spectrometry: Probing Gas-phase Protein ComplexesPreprint
Kung, J. C. K., Kádek, A., Kölbel, K., Bandelow, S., Bari, S., Buck, J., Caleman, C., Commandeur, J., Damjanović, T., Dörner, S., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.02.14.638288 · Cited by 1
Trendbericht Biochemie: Massenspektrometrie gegen Viren
Lermyte, F. (2021) · Nachrichten aus der Chemie · doi:10.1002/nadc.20214111121
Self-citationTransient Crosslinking Mass Spectrometry: Taking Conformational Snapshots of ProteinsPreprint
Yang, L., Xie, Y., Wang, J., Zou, G., Ruan, X., Wang, Y., Xia, D., Sun, H., Xu, X., Zheng, Q., et al. (2022) · Research Square · doi:10.21203/rs.3.rs-1976601/v1
Chapman, E. A., Roberts, D. S., Tiambeng, T. N., Andrews, J., Wang, M., Reasoner, E. A., Melby, J. A., Li, B. H., Kim, D., Alpert, A. J., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.13.544817
Self-citationAdvances in Structural Proteomics using Mass Spectrometry
Otun, S., Mokhantso, T., & Achilonu, I. (2024) · Applications of modern mass spectrometry · doi:10.2174/9789815050059124020007
Chan, H., Krichel, B., Bandura, L. J., Chapman, E. A., Rogers, H. T., Fischer, M. S., Roberts, D. S., Gao, Z., Wang, M., Wu, J., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.15.648965
Self-citationProteomics in plant-fungi interactions: Fundamental concepts to emerging innovations
Priya, D. S., Manikandan, K., Johnson, I., Jeyalakshmi, C., Renuka, R., & Karthikeyan, M. (2025) · Physiological and Molecular Plant Pathology · doi:10.1016/j.pmpp.2025.102878 · Cited by 1
Santos-Fernandez, M., Fouque, K. J. D., Pita, S. S. D. R., Chapagain, P. P., Leng, F., & Fernandez-Lima, F. A. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00357
Figueiredo, I. D. (2024) · theses.fr (ABES) · doi:10.70675/e26318dazc588z42e6z90edz96ccb2ee6e71
Nouchikian, L. (2023) · theses.fr (ABES) · doi:10.70675/ae1b34afz3360z4758zb095z89c58db2a12f
Wang, H.-W., Hong, Y.-L., Chiang, T.-Y., & Lai, S. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c01549
Deep Proteoform Sequencing with Top-Down Direct Mass TechnologyPreprint
Durbin, K. R., Su, T., Fellers, R. T., McGee, J. P., Fisher, N. P., Hollas, M. A. R., Kafader, J. O., & Kelleher, N. L. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.29.728917
Letissier, L., Beaumal, C., Nabiyeva, T., Criscuolo, F., Bertile, F., Schaeffer‐Reiss, C., Cianférani, S., & Hernandez‐Alba, O. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.6c00041
Zhang, J., Huang, A., Lian, Y., Chen, J., Zhao, X., Zhu, D., & Cai, C. (2026) · Foods · doi:10.3390/foods15132386
“This may reflect altered protein ionization efficiency and exposure state in the encapsulating matrix [32,34].”
Edwards, R. L., Hale, O. J., Vickers, S., & Cooper, H. J. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.6c00165 · Cited by 1
Application of mass spectrometry techniques for analysis of higher order structure of proteins
Herath, D., Walls, K. N., Dollar, A. N., & Webb, I. (2026) · The Analyst · doi:10.1039/d6an00710d
Brocca, S., Ponzini, E., Santambrogio, C., & Grandori, R. (2026) · Frontiers in Biophysics · doi:10.3389/frbis.2026.1887194
Keeping It Native: Non‐Denaturing Approaches to Top‐Down Protein Mass Spectrometry
Xiao, M., Maciel, E. V. S., Lermyte, F., & Skinner, O. S. (2026) · Mass Spectrometry Reviews · doi:10.1002/mas.70050
Self-citation
Metadata
- Authors
- Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F.
- Affiliations
- Pacific Northwest National Laboratory (US)
- University of California, Los Angeles (US)
- University of Wisconsin–Madison (US)
- Environmental Molecular Sciences Laboratory
- Technische Universität Darmstadt (DE)
- Corresponding author
- Lermyte, Frederik
- ORCID
- Venue
- Chemical Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2020
- Volume
- 11
- Issue
- 48
- Pages
- 12918-12936
- ISSN
- 2041-6520 (ISSN-L)
- 2041-6539
- PMC
- PMC8163214
- OpenAlex
- W3093581066
- Cited by
- 146
- References
- 179
- Citations by year
- 2026: 17 · 2025: 24 · 2024: 26 · 2023: 27 · 2022: 29 · 2021: 18 · 2020: 5
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Chemical Science (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Department of Energy (DE-AC05-76RL01830, DE-FC02-02ER63421)
- National Institutes of Health (GM007185, GM117058, GM125085, R01GM103479, R01HL096971, T32 HL00793619-19)
- Hessisches Ministerium für Wissenschaft und Kunst (LOEWE: TRABITA)
- National Science Foundation (CHE 1808492)
- Fonds De La Recherche Scientifique - FNRS (Rhizoclip EOS 18000802)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- native mass spectrometry, top-down mass spectrometry, protein structure, protein complexes, post-translational modification, ligand binding, metal ion binding, protein folding, complex stoichiometry, protein sequence determination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-05, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-05 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.