Cited by 7Tissue Engineering and Regenerative MedicineCardiac Valve Diseases and TreatmentsBone Tissue Engineering Materials

Biomimetic polymeric transcatheter heart valve leaflets with low calcification and good regenerative ability

Wang, Xiaoxiao, Jiang, Honghui, Zhang, Wenjie, Kong, Yuanyuan, Kong, Deling, Liu, Jing, Wang, Zhihong·2023·Journal of Materials Chemistry B

Abstract

Transcatheter aortic valve replacement (TAVR) technology is quickly advancing in clinic, however, as it expands to low-risk populations and younger patients (age <65 years), device durability is becoming a major challenge.

Integrity signals

Registry

Crossref · 10.1039/d3tb00761h

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Biomimetic composite scaffold of PLCL, gelatin, hyaluronic acid, and fibroin proteins has appropriate mechanical strength, low calcification deposition and good regenerative ability in rat subcutaneous implantation.

    “The results of subcutaneous implantation in rats showed that the biomimetic composite scaffold had appropriate mechanical strength, low calcification deposition and good regenerative ability [175].”

The citation lists haven’t been fetched yet

References 33 · Cited by 7

Authors
Wang, X., Jiang, H., Zhang, W., Kong, Y., Kong, D., Liu, J., & Wang, Z.
Affiliations
  • Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
  • Tianjin Center for Medical Device Evaluation and Inspection, Tianjin, China
Corresponding author
  • Kong, Deling
  • Liu, Jing
  • Wang, Zhihong
Venue
Journal of Materials Chemistry B
Published
2023
Volume
11
Issue
25
Pages
5805-5816
ISSN
  • 2050-750X (ISSN-L)
  • 2050-7518
OpenAlex
W4379377054
Cited by
7
References
33
Citations by year
2026: 1 · 2025: 3 · 2024: 3
FWCI
1.87
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Materials Chemistry B (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (32071356, 82272158)
  • Science Fund for Distinguished Young Scholars of Tianjin (22JCJQJC00110)
  • Fundamental Research Funds for the Central Universities (3332022069)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
hydroxyapatite, calcification resistance, tissue regeneration, angiogenesis, cell infiltration, mechanical strength, polymeric biomaterials
MeSH terms
Animals, Aortic Valve, Aortic Valve Stenosis, Calcinosis, Cells, Cultured, Polymers, Tissue Engineering, Biomimetics, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review