Thermodynamics of water sorption by perfluorosulphonate (Nafion-117) and polystyrene–divinylbenzene sulphonate (Dowex 50W) ion-exchange resins at 298 ± 1 K
The DOI matches its Crossref record.
Abstract
Water sorption as a function of activity (aH2O) by H+-, Li+-, N(CH3)4+- and Cs+-exchanged forms of a perfluorosulphonate ion exchanger (Nafion-117) and by 4 and 8% crosslinked Dowex 50 W resins has been investigated in order to derive sorption isotherms using the isopiestic technique. All exchangers show the sequence of water sorption as H+ > Li+ > N(CH3)4+ > Cs+. However, the H+ and Li+ forms of Nafion-117 absorb significantly larger amounts of water, while the Cs+ form sorbs much less water at all water activities compared to the corresponding ionic forms of Dowex 50W × 8, the N(CH3)+4 isotherms of the two exchangers being quite close to each other. Sorption of water by the 4 and 8% crosslinked Dowex 50W resins is found to be the same at low aH2O( < 0.55), but the 4% crosslinked exchanger sorbs more water in the higher aH2O region. The overall decrease in free energy on water sorption (–ΔGsw) computed from the isotherms follows the sequence Cs+-117 < Cs+-× 8 < N(CH3)+4-117 < N(CH3)+4-× 8 < Cs+-× 4 < N(CH3)+4-× 4 < Li+-× 8 < Li+-× 4 < H+-× 8 < H+-× 4 < Li+-117 < H+-117. Following different procedures for Nafion and Dowex resins, cationic hydration numbers (n+) evaluated reveal greater hydration of H+ and Li+ in Nafion compared to that in Dowex resins. Cs+ in Dowex resins is reasonably hydrated, but in Nafion a solvent-shared ion pair of the type SO–3(H2O)Cs+ appears to form. Swelling pressures (π) computed for the two types of exchangers follow the order Nafion-117) > Dowex 50W × 8 > Dowex 50W × 4 (any ionic form). The results are discussed in relation to the relative degrees of hydration of the (respective) ions, including the sulphonate anion, and the differences between the two types of ion exchangers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Thin-film catalyst layers for polymer electrolyte fuel cell electrodes
Wilson, M. S., & Gottesfeld, S. (1992) · Journal of Applied Electrochemistry · doi:10.1007/bf01093004 · Cited by 871
Fundamental water and salt transport properties of polymeric materials
Geise, G. M., Paul, D. R., & Freeman, B. D. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.07.001 · Cited by 783
Polymer Electrolyte Fuel Cells
Gottesfeld, S., & Zawodzinski, T. A. (1997) · Advances in Electrochemical Sciences and Engineering · doi:10.1002/9783527616794.ch4 · Cited by 477
Characterization of polymer electrolytes for fuel cell applications
ZAWODZINSKIJR, T., SPRINGER, T., URIBE, F., & GOTTESFELD, S. (1993) · Solid State Ionics · doi:10.1016/0167-2738(93)90295-e · Cited by 378
Water‐sorption and transport properties of Nafion 117 H
Morris, D. R., & Sun, X. (1993) · Journal of Applied Polymer Science · doi:10.1002/app.1993.070500816 · Cited by 377
BROKA, K., & EKDUNGE, P. (1997) · Journal of Applied Electrochemistry · doi:10.1023/a:1018469520562 · Cited by 360
Watanabe, M., Uchida, H., & Emori, M. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp973477e · Cited by 238
Swelling study of perfluorosulphonated ionomer membranes
Gebel, G., Aldebert, P., & Pineri, M. (1993) · Polymer · doi:10.1016/0032-3861(93)90086-p · Cited by 216
Thermodynamics and Proton Transport in Nafion
Choi, P., Jalani, N. H., & Datta, R. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.1855872 · Cited by 211
Adachi, M., Navessin, T., Xie, Z., Frisken, B., & Holdcroft, S. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3116922 · Cited by 79
Gas permeation in perflurosulfonated membranes: Influence of temperature and relative humidity
Giacinti Baschetti, M., Minelli, M., Catalano, J., & Sarti, G. C. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.06.104 · Cited by 74
Understanding the Effects of Compression and Constraints on Water Uptake of Fuel-Cell Membranes
Kusoglu, A., Kienitz, B. L., & Weber, A. Z. (2011) · Journal of The Electrochemical Society · doi:10.1149/2.097112jes · Cited by 72
Pressure–Volume–Temperature properties of polyolefin liquids and their melt miscibility
(1999) · doi:10.1002/(sici)1099-0488(19991015)37:20<2835::aid-polb3>3.0.co;2-1
Metadata
- Authors
- Pushpa, K. K., Nandan, D., & Iyer, R. M.
- Venue
- Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 1988
- Volume
- 84
- Issue
- 6
- Pages
- 2047
- ISSN
- 0300-9599 (ISSN-L)
- OpenAlex
- W1979152887
- Cited by
- 92
- References
- 0
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.