Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciation

Larsen, Erik H., Stürup, Stefan·1994·J. Anal. At. Spectrom.

Abstract

Addition of carbon as methanol or ammonium carbonate to the aqueous analyte solutions in combination with increased plasma power input enhanced the inductively coupled plasma mass spectrometry (ICP-MS) signal intensities of arsenic and selenium. In the presence of the optimum 3% v/v methanol concentration the signal intensities achieved were about 4500–5000 counts s–1 per ng ml–1 of arsenic and about 700–1100 counts s–1 per ng ml–1 of selenium (82Se), corresponding to enhancement factors of 3.5–4.5 compared with aqueous solution for the two elements. Differences in sensitivity (calculated on the basis of analyte atom) were observed between the individual arsenic species and between the selenium species in aqueous as well as in carbon-added solutions. The presence of 3% v/v methanol in the analyte solutions doubled the level of the background signal for arsenic and selenium, but its fluctuation (noise) was not increased. Therefore, the observed increase in analyte sensitivity led to a similar increase in signal-to-noise ratio. The addition of carbon as ammonium carbonate enhanced the arsenic signal by a similar factor but caused severe contamination of the ICP-MS instrument by carbon. In the 3% v/v methanol solutions of arsenic and selenium the signal intensity from antimony (internal standard) was enhanced by a factor of 1.5, which indicates that the enhancement effect of the arsenic and selenium signals by methanol is only to a limited extent caused by improved sample transport/nebulization efficiency. It is proposed that an increased population of carbon ions or carbon-containing ions in the plasma facilitates a more complete ionization of analytes lower in ionization energy than carbon itself. The enhanced detection power for arsenic was applied to arsenic speciation by high-performance liquid chromatography (HPLC)–ICP-MS, and made possible the detection of the arsenocholine ion (AsC) in extracts of shrimp at the 5–10 ng g–1 concentration level. The limit of detection was improved by a factor of 3.4 after addition of methanol and was 4.7 ng g–1 as the AsC ion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/ja9940901099

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 299

Metadata

Authors
Larsen, E. H., & Stürup, S.
Venue
J. Anal. At. Spectrom.
Published
1994
Volume
9
Issue
10
Pages
1099-1105
ISSN
  • 0267-9477 (ISSN-L)
  • 1364-5544
OpenAlex
W2167470723
Cited by
299
References
5
FWCI
4.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciation. https://app.cochat.ai/papers/10.1039/ja9940901099
The paper
Larsen, E. H., & Stürup, S. (1994). Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciation. J. Anal. At. Spectrom. https://doi.org/10.1039/ja9940901099

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.