The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Inductively Coupled Plasma Mass Spectrometry: Introduction to Analytical Aspects
Open accessAbstract
Inductively coupled plasma mass spectrometry (ICP-MS) is an analytical technique that can be used to measure elements at trace levels in biological fluids. Although older techniques such as atomic absorption and atomic emission are still in use by some laboratories, there has been a slow shift toward ICP-MS, particularly in the last decade. As this shift is likely to continue, clinical scientists should be aware of the analytical aspects of ICP-MS, as well as the potential for both spectroscopic and non-spectroscopic interference, and strategies that can be employed to eliminate or mitigate these issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toxicity, mechanism and health effects of some heavy metals
Jaishankar, M., Tseten, T., Anbalagan, N., Mathew, B. B., & Beeregowda, K. N. (2014) · Interdisciplinary Toxicology · doi:10.2478/intox-2014-0009 · Cited by 6,402
Psychogios, N., Hau, D. D., Peng, J., Guo, A. C., Mandal, R., Bouatra, S., Sinelnikov, I., Krishnamurthy, R., Eisner, R., Gautam, B., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016957 · Cited by 1,703
Atomic Absorption Spectrometry
(2014) · Undergraduate Instrumental Analysis · doi:10.1201/b15921-10 · Cited by 1,221
Houk, R. S., Fassel, V. A., Flesch, G. D., Svec, H. J., Gray, A. L., & Taylor, C. E. (1980) · Analytical Chemistry · doi:10.1021/ac50064a012 · Cited by 766
Principles and applications of liquid chromatography-mass spectrometry in clinical biochemistry.
Pitt, J. J. (2009) · PubMed · Cited by 444
Present Trends and the Future of Zircon in Geochronology: Laser Ablation ICPMS
Kosler, J. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530243 · Cited by 324
Olivares, J. A., & Houk, R. S. (1986) · Analytical Chemistry · doi:10.1021/ac00292a008 · Cited by 299
Larsen, E. H., & Stürup, S. (1994) · J. Anal. At. Spectrom. · doi:10.1039/ja9940901099 · Cited by 299
Navas-Acien, A., Francesconi, K. A., Silbergeld, E. K., & Guallar, E. (2011) · Environmental Research · doi:10.1016/j.envres.2010.10.009 · Cited by 243
Palmer, C. D., Lewis, M. E., Geraghty, C. M., Barbosa, F., & Parsons, P. J. (2006) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2006.09.001 · Cited by 232
Cited by
Can Reuse of Stormwater Detention Pond Water Meet Community Urban Agriculture Needs?
Ortiz, E., Mayr Mejia, A., Borely, E., Schauer, L., Young Green, L., & Trotz, M. (2025) · Sustainability · doi:10.3390/su17020523 · Cited by 2
Metadata
- Authors
- Wilschefski, S., & Baxter, M.
- Venue
- Clinical Biochemist Reviews
- Publisher
- Walter de Gruyter GmbH
- Published
- 2019-08-28
- Volume
- 40
- Issue
- 3
- Pages
- 115-133
- ISSN
- 0159-8090 (ISSN-L)
- OpenAlex
- W2991534396
- Cited by
- 684
- References
- 24
- FWCI
- 28.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inductively Coupled Plasma Mass Spectrometry: Introduction to Analytical Aspects. https://app.cochat.ai/papers/10.33176/aacb-19-00024
- The paper
- Wilschefski, S., & Baxter, M. (2019). Inductively Coupled Plasma Mass Spectrometry: Introduction to Analytical Aspects. Clinical Biochemist Reviews. https://doi.org/10.33176/aacb-19-00024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.