Evaluation of Multi-Frequency Bio-Impedance Analysis for the Assessment of Extracellular and Total Body Water in Surgical Patients
The DOI matches its Crossref record.
Abstract
1. Multi-frequency bio-impedance analysis has been used to estimate extracellular and total body water in a heterogeneous group of 43 surgical patients (23 males, 20 females). 2. Radioisotope-dilution methods were used for the measurement of extracellular and total body water. 3. Resistance and reactance were measured between wrist and ankle at frequencies from 5 kHz to 1 MHz. 4. Extracellular and total body water were estimated by multiple stepwise regression using the radioisotope values as the dependent variables. The parameters included in the regression were: resistance and reactance at each frequency, body habitus parameters, plasma albumin and plasma sodium. 5. The standard errors of the estimates between the measured and esitmated values were 1.73 litres (coefficient of variation 9.6%) and 2.17 litres (coefficient of variation 6.0%) for extracellular and total body water, respectively. 6. These errors represent a useful improvement relative to those obtained from anthropometric estimates. However, the improvements relative to the use of a single frequency (50 kHz) are not clinically significant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Jaffrin, M. Y., & Morel, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.009 · Cited by 490
Selberg, O., & Selberg, D. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0570-4 · Cited by 476
Marra, M., Sammarco, R., De Lorenzo, A., Iellamo, F., Siervo, M., Pietrobelli, A., Donini, L. M., Santarpia, L., Cataldi, M., Pasanisi, F., et al. (2019) · Contrast Media & Molecular Imaging · doi:10.1155/2019/3548284 · Cited by 401
Metadata
- Authors
- Hannan, W. J., Cowen, S. J., Fearon, K. C. H., Plester, C. E., Falconer, J. S., & Richardson, R. A.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1994-04-01
- Volume
- 86
- Issue
- 4
- Pages
- 479-485
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W1599277339
- Cited by
- 122
- References
- 0
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Multi-Frequency Bio-Impedance Analysis for the Assessment of Extracellular and Total Body Water in Surgical Patients. https://app.cochat.ai/papers/10.1042/cs0860479
- The paper
- Hannan, W. J., Cowen, S. J., Fearon, K. C. H., Plester, C. E., Falconer, J. S., & Richardson, R. A. (1994). Evaluation of Multi-Frequency Bio-Impedance Analysis for the Assessment of Extracellular and Total Body Water in Surgical Patients. Clinical Science. https://doi.org/10.1042/cs0860479
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.