The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods
Abstract
This paper reviews various bioimpedance methods permitting to measure non-invasively, extracellular, intracellular and total body water (TBW) and compares BIA methods based on empirical equations of the wrist-ankle resistance or impedance at 50 kHz, height and weight with BIS methods which rely on an electrical model of tissues and resistances measured at zero and infinite frequencies. In order to compare these methods, impedance measurements were made with a multifrequency Xitron 4200 impedance meter on 57 healthy subjects which had undergone simultaneously a Dual X-ray absorptiometry examination (DXA), in order to estimate their TBW from their fat-free-mass. Extracellular (ECW) and TBW volumes were calculated for these subjects using the original BIS method and modifications of Matthie[Matthie JR. Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy. J Appl Physiol 2005;99:780-1], Jaffrin et al. [Jaffrin MY, Fenech M, Moreno MV, Kieffer R. Total body water measurement by a modification of the bioimpédance spectroscopy method. Med Bio Eng Comput 2006;44:873-82], Moissl et al. [Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas 2006;27:921-33] and their TBW resistivities were compared and discussed. ECW volumes were calculated by BIA methods of Sergi et al. [Sergi G, Bussolotto M, Perini P, Calliari I, et al. Accuracy of bioelectrical bioimpedance analysis for the assessment of extracellular space in healthy subjects and in fluid retention states. Ann Nutr Metab 1994;38(3):158-65] and Hannan et al. [Hannan WJ, Cowen SJ, Fearon KC, Plester CE, Falconer JS, Richardson RA. Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci 1994;86:479-85] and TBW volumes by BIA methods of Kushner and Schoeller [Kushner RF, Schoeller DA. Estimation of total body water by bioelectrical impedance analysis. Am J Clin Nutr 1986;44(3):417-24], Lukaski et al. [Lukaski HC, Bolonchuk WW. Estimation of body fluid volumes using tetrapolar bioelectrical impedance measurements. Aviat Space Environ Med 1988;59:1163-9], Hannan et al. [Hannan WJ, Cowen SJ, Fearon KC, Plester CE, Falconer JS, Richardson RA. Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clinical Science 1994;86:479-85], Deurenberg et al. [Deurenberg P, van der Koy K, Leenen R, Westrate JA, Seidell JC. Sex and age specific prediction formulas for estimating body composition from bioelectric impedance: a cross validation study. Int J Obesity 1991;15:17-25] These volumes were compared against those given by BIS method and, in the case of TBW, with those by DXA. For ECW, a good agreement was found between various BIS methods and that of Sergi while Hannan's values were higher. Both Matthie's and Moissl's methods gave mean TBW resistivities and volumes lower than those of Jaffrin's and DXA methods. Kushner et al. method gave values of TBW not significantly different from those of Jaffrin et al. and DXA, as Hannan's method in men, but Lukaski and Deurenberg methods led to an underestimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Estimation of total body water by bioelectrical impedance analysis
Kushner, R., & Schoeller, D. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.3.417 · Cited by 772
Predicting body cell mass with bioimpedance by using theoretical methods: a technological review
De Lorenzo, A., Andreoli, A., Matthie, J., & Withers, P. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.5.1542 · Cited by 654
Physiology of the Kidney and Body Fluids
PITTS, R. F., & JACOBY, J. (1963) · Anesthesiology · doi:10.1097/00000542-196309000-00036 · Cited by 613
Body fluid volume determination via body composition spectroscopy in health and disease
Moissl, U. M., Wabel, P., Chamney, P. W., Bosaeus, I., Levin, N. W., Bosy-Westphal, A., Korth, O., Müller, M. J., Ellegård, L., Malmros, V., et al. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/9/012 · Cited by 608
THE MEASUREMENT OF TOTAL BODY WATER IN THE HUMAN SUBJECT BY DEUTERIUM OXIDE DILUTION
Schloerb, P. R., Friis-Hansen, B. J., Edelman, I. S., Solomon, A. K., & Moore, F. D. (1950) · Journal of Clinical Investigation · doi:10.1172/jci102366 · Cited by 411
Why bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361
Deurenberg, P., van der Kooy, K., Leenen, R. C. A., Weststrate, J. A., & Seidell, J. C. (1991) · PubMed · Cited by 347
Membranes, ions, and impulses : a chapter of classical biophysics
Cole, K. S. (1968) · University of California Press eBooks · Cited by 245
Cited by
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
Bioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Volume overload correlates with cardiovascular risk factors in patients with chronic kidney disease
Hung, S.-C., Kuo, K.-L., Peng, C.-H., Wu, C.-H., Lien, Y.-C., Wang, Y.-C., & Tarng, D.-C. (2014) · Kidney International · doi:10.1038/ki.2013.336 · Cited by 254
Savastano, S., Belfiore, A., Di Somma, C., Mauriello, C., Rossi, A., Pizza, G., De Rosa, A., Prestieri, G., Angrisani, L., & Colao, A. (2010) · Obesity Surgery · doi:10.1007/s11695-009-0006-5 · Cited by 100
Teigen, L. M., Kuchnia, A. J., Mourtzakis, M., & Earthman, C. P. (2017) · Nutrition in Clinical Practice · doi:10.1177/0884533616676264 · Cited by 75
Metadata
- Authors
- Jaffrin, M. Y., & Morel, H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2008-08-03
- Volume
- 30
- Issue
- 10
- Pages
- 1257-1269
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2164020604
- Cited by
- 490
- References
- 30
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods. https://app.cochat.ai/papers/10.1016/j.medengphy.2008.06.009
- The paper
- Jaffrin, M. Y., & Morel, H. (2008). Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2008.06.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.