The DOI matches its Crossref record.
Changes in Pulse Transit Time and Pulse Rate as Markers of Arousal from Sleep in Normal Subjects
Abstract
1. Obstructive sleep apnoea and its variants often provoke hundreds of short arousals that lead to the most important symptom, disabling hypersomnolence. The measurement of sleep in these conditions requires the documentation of these short arousals and this is conventionally done by manual inspection of the sleeping EEG, a laborious procedure. 2. Other markers of ‘arousal’, that are easier to measure and document, include several cardiovascular signals that change as part of the orienting reflex: pulse rate rise, blood pressure rise, skin vasoconstriction, for example. 3. Pulse transit time (measured as the interval from the ECG R-wave until the arrival of the pulse pressure wave at the periphery, about 250 ms) varies inversely with blood pressure and provides a beat-to-beat estimation of blood pressure changes. 4. In eight normal subjects we have assessed the relationship between transient EEG arousals of different length (provoked by external stimuli) and changes in both pulse transit time and heart rate. 5. Significant falls in pulse transit time occurred in response to external stimuli [15.1 (SEM 1.4) ms], indicating a rise in blood pressure, and were significant even when there was no discernible change in the EEG [9.9 (SEM 2.6) ms]. Significant changes in heart rate also occurred [10.3 (SEM 1.2) beats/min], but were slightly less sensitive than changes in pulse transit time. 6. Changes in pulse transit time (and to a lesser extent pulse rate) are sensitive markers of EEG arousal. As such they should be useful to include when monitoring sleep and its disorders, particularly since pulse transit time recorders can easily be made portable for home use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Role of Arousals in the Pathogenesis of Obstructive Sleep Apnea
Younes, M. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200307-1023oc · Cited by 456
The upper airway in sleep: physiology of the pharynx
Ayappa, I., & Rapoport, D. M. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0238 · Cited by 340
Cardiac activation during arousal in humans: further evidence for hierarchy in the arousal response
Sforza, E., Jouny, C., & Ibanez, V. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00363-1 · Cited by 317
Pulse transit time: an appraisal of potential clinical applications
Smith, R. P., Argod, J., Pepin, J.-L., & Levy, P. A. (1999) · Thorax · doi:10.1136/thx.54.5.452 · Cited by 317
Metadata
- Authors
- Pitson, D., Chhina, N., Knijn, S., van Herwaaden, M., & Stradling, J.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1994-08-01
- Volume
- 87
- Issue
- 2
- Pages
- 269-273
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W16857004
- Cited by
- 172
- References
- 0
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Changes in Pulse Transit Time and Pulse Rate as Markers of Arousal from Sleep in Normal Subjects. https://app.cochat.ai/papers/10.1042/cs0870269
- The paper
- Pitson, D., Chhina, N., Knijn, S., van Herwaaden, M., & Stradling, J. (1994). Changes in Pulse Transit Time and Pulse Rate as Markers of Arousal from Sleep in Normal Subjects. Clinical Science. https://doi.org/10.1042/cs0870269
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.