Dual-Energy X-Ray Absorptiometry Measurements of Body Composition: Effects of Depth and Tissue Thickness, Including Comparisons with Direct Analysis
The DOI matches its Crossref record.
Abstract
1. There are few data regarding the accuracy of Hologic QDR-1000W dual-energy X-ray absorptiometry for the measurement of body composition. In two studies, one in an in vitro experimental system using oil and water mixtures and the other in samples of pork meat, the effect of depth and tissue thickness on the measured composition was assessed. In the latter study the measured fat mass was compared with that measured by direct analysis. 2. All data indicated a trend in the measured fat mass with depth, such that more fat was measured at extremes of depth (<10 cm and >25 cm) than at intermediate depths. 3. In samples of meat weighing approximately 55 kg, dual X-ray absorptiometry significantly underestimated the absolute fat mass compared with direct analysis (mean 20.4 ± 1.65%) by 5–8% or 1–4 kg of fat. 4. These findings are of direct relevance to both clinical and research work using this technique to measure body composition, in particular in circumstances in which changes in body composition and/or tissue thickness are anticipated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
Prior, B. M., Cureton, K. J., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M., & Lewis, R. D. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.2.623 · Cited by 317
Hangartner, T. N., Warner, S., Braillon, P., Jankowski, L., & Shepherd, J. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.08.007 · Cited by 242
“(2,11e13), between different models of the same manufacturer (12,14e16), the same densitometer with different analysis software (5,10), and even using different scan modes and geometries on the same device (17).”
BackgroundComparison of anthropometry to DXA: a new prediction equation for men
Ball, S. D., Altena, T. S., & Swan, P. D. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602003 · Cited by 173
“Research however demonstrates that beam hardening is of minimal concern in DXA’s ability to predict %BF (Jebb et al, 1995).”
Background
Metadata
- Authors
- Jebb, S. A., Goldberg, G. R., Jennings, G., & Elia, M.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1995-03-01
- Volume
- 88
- Issue
- 3
- Pages
- 319-324
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2439290079
- Cited by
- 81
- References
- 0
- FWCI
- 4.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Energy X-Ray Absorptiometry Measurements of Body Composition: Effects of Depth and Tissue Thickness, Including Comparisons with Direct Analysis. https://app.cochat.ai/papers/10.1042/cs0880319
- The paper
- Jebb, S. A., Goldberg, G. R., Jennings, G., & Elia, M. (1995). Dual-Energy X-Ray Absorptiometry Measurements of Body Composition: Effects of Depth and Tissue Thickness, Including Comparisons with Direct Analysis. Clinical Science. https://doi.org/10.1042/cs0880319
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.