Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 345

The DOI matches its Crossref record.

Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress

HARMS, Mark P. M., WESSELING, Karel H., POTT, Frank, JENSTRUP, Morten, VAN GOUDOEVER, Jeroen, SECHER, Niels H., VAN LIESHOUT, Johannes J.·1999·Clinical Science

Abstract

The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and evaluated whether, under orthostatic stress, flow may be derived from both an invasive and a non-invasive determination of arterial pressure. In 10 young adults, Modelflow stroke volume (MFSV) was computed from both intra-brachial arterial pressure (IAP) and non-invasive finger pressure (FINAP) measurements. For comparison, a computer-controlled series of four thermodilution estimates (thermodilution-determined stroke volume; TDSV) were averaged for the following positions: supine, standing, head-down tilt at 20 ° (HDT20) and head-up tilt at 30 ° and 70 ° (HUT30 and HUT70 respectively). Data from one subject were discarded due to malfunctioning thermodilution injections. A total of 155 recordings from 160 series were available for comparison. The supine TDSV of 113±13 ml (mean±S.D.) dropped by 40% to 68±14 ml during standing, by 24% to 86±12 ml during HUT30, and by 51% to 55±15 ml during HUT70. During HDT20, TDSV was 114±13 ml. MFSV for IAP underestimated TDSV during HDT20 (-6±6 ml; P < 0.05), but that for FINAP did not (-4±7 ml; not significant). For HUT70 and standing, MFSV for IAP overestimated TDSV by 11±10 ml (HUT70; P < 0.01) and 12±9 ml (standing; P < 0.01). However, the offset of MFSV for FINAP was not significant for either HUT70 (3±8 ml) or standing (3±9 ml). In conclusion, due to orthostasis, changes in the aortic transmural pressure may lead to an offset in MFSV from IAP. However, Modelflow correctly calculated aortic flow from non-invasively determined finger pressure during orthostasis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs0970291

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 345

Metadata

Authors
HARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J.
Venue
Clinical Science
Published
1999-07-21
Volume
97
Issue
3
Pages
291-301
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2072486627
Cited by
345
References
0
FWCI
11.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress. https://app.cochat.ai/papers/10.1042/cs0970291
The paper
HARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J. (1999). Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress. Clinical Science. https://doi.org/10.1042/cs0970291

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.