Oximetry spectral analysis in the diagnosis of obstructive sleep apnoea
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Using spectral analysis of oximetry data, we prospectively evaluated the validity of this methodology in patients clinically suspected of suffering from obstructive sleep apnoea (OSA). A total of 233 outpatients were studied. Nocturnal oximetry was performed simultaneously with conventional polysomnography for all participants. The power density of oxygen saturation was analysed using Fast-Fourier transformation of the oximetric signal. Nocturnal oximetry test results were considered as abnormal (suspicion of OSA) if a peak in the spectrum between the period boundaries 30 and 70 s was observed. A normal test result was defined as the absence of the 30–70 s peak from the spectrum. Single-blind evaluation was performed by three independent observers, and agreement of two or more of these was considered definitive. The peak amplitude and the ratio of the area enclosed in the 30–70 s peak to the total area of the spectrum (rS) were measured. The presence of a peak has a sensitivity of 78%, a specificity of 89%, a positive predictive value of 89% and a negative predictive value of 78%. Apnoea–hypopnoea indexes were correlated significantly with peak amplitude (r = 0.74; P< 0.001) and with rS (r = 0.69; P< 0.001). For a peak amplitude threshold of 0.7%2, the sensitivity was 94% and the specificity was 65% for OSA diagnosis. Using a threshold for rS of 0.15, the sensitivity was 91% and the specificity was 67%. Thus the spectral analysis of nocturnal oximetry and identification of a peak at 30–70 s could be useful as a diagnostic technique for OSA subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Cited by
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Overnight Pulse Oximetry for Sleep-Disordered Breathing in Adults
Netzer, N., Eliasson, A. H., Netzer, C., & Kristo, D. A. (2001) · Chest · doi:10.1378/chest.120.2.625 · Cited by 311
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Levy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00373-5 · Cited by 125
“Zamarrón et al.(45) assessed PSD biomarkers on a total of 250 subjects between the ages of 21 and 82 years and obtained a sensitivity of 78.”
BackgroundInfluentialThe Value of Oxygen Desaturation Index for Diagnosing Obstructive Sleep Apnea: A Systematic Review
Rashid, N. H., Zaghi, S., Scapuccin, M., Camacho, M., Certal, V., & Capasso, R. (2021) · The Laryngoscope · doi:10.1002/lary.28663 · Cited by 115
Oxygen saturation regularity analysis in the diagnosis of obstructive sleep apnea
del Campo, F., Hornero, R., Zamarrón, C., Abasolo, D. E., & Álvarez, D. (2006) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2005.10.005 · Cited by 56
“Another study by our own group [30,31] demonstrated that spectral analysis and peak detection in the period 30—70 s of SaO2 or heart rate signal obtained from nocturnal pulse oximetry presented a sensitivity of 90% (84—94) and a specificity of 82% (74—88) for OSA diagnosis which resembles the findings for ApEn.”
Self-citation
Metadata
- Authors
- ZAMARRÓN, C., ROMERO, P. V., RODRIGUEZ, J. R., & GUDE, F.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1999-08-24
- Volume
- 97
- Issue
- 4
- Pages
- 467-473
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2041677865
- Cited by
- 61
- References
- 1
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.