CoChat

Digital oximetry biomarkers for assessing respiratory function: standards of measurement, physiological interpretation, and clinical use

Open access
Levy, Jeremy, Álvarez, Daniel, Rosenberg, Aviv A., Alexandrovich, Alexandra, del Campo, Félix, Behar, Joachim A. · 2021 · npj Digital Medicine

The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.

Abstract

Pulse oximetry is routinely used to non-invasively monitor oxygen saturation levels. A low oxygen level in the blood means low oxygen in the tissues, which can ultimately lead to organ failure. Yet, contrary to heart rate variability measures, a field which has seen the development of stable standards and advanced toolboxes and software, no such standards and open tools exist for continuous oxygen saturation time series variability analysis. The primary objective of this research was to identify, implement and validate key digital oximetry biomarkers (OBMs) for the purpose of creating a standard and associated reference toolbox for continuous oximetry time series analysis. We review the sleep medicine literature to identify clinically relevant OBMs. We implement these biomarkers and demonstrate their clinical value within the context of obstructive sleep apnea (OSA) diagnosis on a total of n = 3806 individual polysomnography recordings totaling 26,686 h of continuous data. A total of 44 digital oximetry biomarkers were implemented. Reference ranges for each biomarker are provided for individuals with mild, moderate, and severe OSA and for non-OSA recordings. Linear regression analysis between biomarkers and the apnea hypopnea index (AHI) showed a high correlation, which reached $$\overline R ^2 = 0.82$$ R ¯ 2 = 0.82 . The resulting python OBM toolbox, denoted “pobm”, was contributed to the open software PhysioZoo ( physiozoo.org ). Studying the variability of the continuous oxygen saturation time series using pbom may provide information on the underlying physiological control systems and enhance our understanding of the manifestations and etiology of diseases, with emphasis on respiratory diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-020-00373-5

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 PhysioZoo OBM interface for oximetry time series analysis. The analysis of an oximetry time series is shown. All the OBM biomarkers are computed for the selected window (in light green).
Fig. 1 PhysioZoo OBM interface for oximetry time series analysis. The analysis of an oximetry time series is shown. All the OBM biomarkers are computed for the selected window (in light green).CC BY · PubMed Central
Fig. 2 Linear correlation between oximetry biomarkers and the AHI. The adjusted (R¯)² is reported for every biomarker and for the 10 biomarkers with the highest (R¯)².
Fig. 2 Linear correlation between oximetry biomarkers and the AHI. The adjusted (R¯)² is reported for every biomarker and for the 10 biomarkers with the highest (R¯)².CC BY · PubMed Central
Fig. 3 Flowchart for continuous oximetry time series analysis. a The raw data are first preprocessed using some of the routines presented in section “Preprocessing”, to remove any non-physiological values that are likely caused by noise. b The recording is then windowed. The size of the analysis windows and whether to consider overlapping windowing is an important consideration and will be research dependent. c Oximetry biomarkers are then computed using the OBM toolbox. d A statistical analysis is performed to obtain a preliminary understanding of the biomarker behavior for the different classes of interest. e Finally, a machine learning model can be used to combine the biomarkers for a regression or classification task.
Fig. 3 Flowchart for continuous oximetry time series analysis. a The raw data are first preprocessed using some of the routines presented in section “Preprocessing”, to remove any non-physiological values that are likely caused by noise. b The recording is then windowed. The size of the analysis windows and whether to consider overlapping windowing is an important consideration and will be research dependent. c Oximetry biomarkers are then computed using the OBM toolbox. d A statistical analysis is performed to obtain a preliminary understanding of the biomarker behavior for the different classes of interest. e Finally, a machine learning model can be used to combine the biomarkers for a regression or classification task.CC BY · PubMed Central
Fig. 4 Example of preprocessing approaches. a shows the time series preprocessed with the delta filter technique, and b shows the same time series preprocessed with the block of data technique.
Fig. 4 Example of preprocessing approaches. a shows the time series preprocessed with the delta filter technique, and b shows the same time series preprocessed with the block of data technique.CC BY · PubMed Central
Fig. 5 PRSA analysis of the oximetry time series. In a, the oximetry time series, with anchor points highlighted. In b, concatenation of PRSA windows, defined around each anchor points. In c, PRSA windows of top of each other. In d, the average of all the PRSA windows.
Fig. 5 PRSA analysis of the oximetry time series. In a, the oximetry time series, with anchor points highlighted. In b, concatenation of PRSA windows, defined around each anchor points. In c, PRSA windows of top of each other. In d, the average of all the PRSA windows.CC BY · PubMed Central
Fig. 6 Power spectral density (PSD) of the oximetry time series. Example on a a non-OSA individual and b a patient with moderate OSA. The band 0.014–0.033 Hz is delineated by the vertical dashed lines. In b, the peak within this band is located at f = 0.017 Hz, as highlighted by the red star.
Fig. 6 Power spectral density (PSD) of the oximetry time series. Example on a a non-OSA individual and b a patient with moderate OSA. The band 0.014–0.033 Hz is delineated by the vertical dashed lines. In b, the peak within this band is located at f = 0.017 Hz, as highlighted by the red star.CC BY · PubMed Central
Fig. 7 Desaturation biomarkers. A, B, C, and D are the fiducials points delimiting a desaturation event.
Fig. 7 Desaturation biomarkers. A, B, C, and D are the fiducials points delimiting a desaturation event.CC BY · PubMed Central
Fig. 8 Illustration of CA90 and CT90 biomarkers. The sum of all the blue areas corresponds to CA90, whereas the sum of all the length arrows corresponds to CT90.
Fig. 8 Illustration of CA90 and CT90 biomarkers. The sum of all the blue areas corresponds to CA90, whereas the sum of all the length arrows corresponds to CT90.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 63 references

Cited by

See all 127

Metadata

Authors
Levy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A.
Affiliations
  • Technion – Israel Institute of Technology (IL)
  • Universidad de Valladolid (ES)
Corresponding author
Behar, Joachim A.
Venue
npj Digital Medicine
Published
2021-01-04
Volume
4
Issue
1
Pages
1-1
ISSN
2398-6352 (ISSN-L)
OpenAlex
W3119755710
Cited by
125
References
62
Citations by year
2026: 9 · 2025: 24 · 2024: 11 · 2023: 33 · 2022: 35 · 2021: 13
FWCI
14.45
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Hispana (publishedVersion, cc-by-nc-nd)
  • University of Valladolid Documentary Repository (University of Valladolid) (publishedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina
  • Intelligent Systems Center
  • Instituto de Salud Carlos III
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
pulse oximetry, oxygen saturation, obstructive sleep apnea, respiratory function, apnea-hypopnea index, polysomnography, reference values, open-source software toolkit, sleep medicine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Digital oximetry biomarkers for assessing respiratory function: standards of measurement, physiological interpretation, and clinical use. https://app.cochat.ai/papers/10.1038/s41746-020-00373-5
The paper
Levy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A. (2021). Digital oximetry biomarkers for assessing respiratory function: standards of measurement, physiological interpretation, and clinical use. npj Digital Medicine. https://doi.org/10.1038/s41746-020-00373-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.