Reproducibility of methods for assessing baroreflex sensitivity in normal controls and in patients with chronic heart failure
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Baroreflex sensitivity (BRS) conveys useful prognostic information in patients with heart disease, yet methods for its quantification suffer from poor reproducibility and test failure in some patients with heart failure. We set out to compare the short-term reproducibility and success rate of four different methods of assessing BRS in normal subjects and patients with chronic heart failure (CHF). A total of 31 patients with CHF and 18 normal controls underwent BRS testing using four techniques: (1) bolus phenylephrine (BRSPhe), (2) α-index in both low- and high-frequency bands (BRSαLF and BRSαHF respectively), (3) the sequence method (BRSSeq), and (4) a new 0.1 Hz controlled-breathing, time-domain analysis method (BRSCbr). Each subject underwent two test episodes with each method on the same day. The average values for BRS in patients and controls respectively were: BRSPhe, 4.4 (±4.4) ms/mmHg and 19.8 (±11.5) ms/mmHg; BRSαLF, 5.6 (±4.1) ms/mmHg and 15.4 (±5.0) ms/mmHg; BRSαHF, 7.1 (±7.0) ms/mmHg and 25.1 (±8.3) ms/mmHg; BRSSeq, 7.7 (±6.3) ms/mmHg and 22.5 (±8.4) ms/mmHg; BRSCbr, 6.6 (±5.9) ms/mmHg and 22.8 (±10.8) ms/mmHg. The coefficients of variation (S.D. of the difference in repeated values divided by mean) in patients and controls respectively were: BRSPhe, 85.6% and 52.2%; BRSαLF, 65.9% and 33.7%; BRSαHF, 99.7% and 52.1%; BRSSeq, 30.7% and 40.4%; BRSCbr, 30.7% and 19.6%. The numbers of test failures in patients were: BRSPhen, 15; BRSαLF, 7; BRSαHF, 5; BRSSeq, 14; BRSCbr, 1. Of the four techniques assessed for measuring BRS, the controlled breathing time-domain method yielded the best reproducibility and lowest failure rate in controls and in patients with CHF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Rovere, M. T. L., Bigger, J. T., Marcus, F. I., Mortara, A., & Schwartz, P. J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11144-8 · Cited by 3,120
Important influence of respiration on human R-R interval power spectra is largely ignored
Brown, T. E., Beightol, L. A., Koh, J., & Eckberg, D. L. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.5.2310 · Cited by 770
Depressed Baroreflex Sensitivity in Patients With Obstructive Sleep Apnea
Carlson, J. T., Hedner, J. A., Sellgren, J., Elam, M., & Wallin, B. G. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.154.5.8912770 · Cited by 239
Cited by
Baroreflex Sensitivity: Measurement and Clinical Implications
La Rovere, M. T., Pinna, G. D., & Raczak, G. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00219.x · Cited by 659
Joseph, C. N., Porta, C., Casucci, G., Casiraghi, N., Maffeis, M., Rossi, M., & Bernardi, L. (2005) · Hypertension · doi:10.1161/01.hyp.0000179581.68566.7d · Cited by 394
Peripheral Chemoreceptor Hypersensitivity: An Ominous Sign in Patients With Chronic Heart Failure
Ponikowski, P., Chua, T. P., Anker, S. D., Francis, D. P., Doehner, W., Banasiak, W., Poole-Wilson, P. A., Piepoli, M. F., & Coats, A. J. S. (2001) · Circulation · doi:10.1161/hc3101.093699 · Cited by 307
Self-citationDeterminants of Spontaneous Baroreflex Sensitivity in a Healthy Working Population
Kardos, A., Watterich, G., de Menezes, R., Csanády, M., Casadei, B., & Rudas, L. (2001) · Hypertension · doi:10.1161/01.hyp.37.3.911 · Cited by 186
“Women 1 (2)§ 7 (6)§ 45 (16)§ 11 (11)§ 64 (11)§”
Slow breathing reduces sympathoexcitation in COPD
Raupach, T., Bahr, F., Herrmann, P., Luethje, L., Heusser, K., Hasenfuß, G., Bernardi, L., & Andreas, S. (2008) · European Respiratory Journal · doi:10.1183/09031936.00109607 · Cited by 163
“Thus, the less intrusive alpha angle method was preferred since it is an accepted method for measuring baroreflex sensitivity [29].”
Method
Metadata
- Authors
- DAVIES, L. C., FRANCIS, D. P., JURÁK, P., KÁRA, T., PIEPOLI, M., & COATS, A. J. S.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1999-09-16
- Volume
- 97
- Issue
- 4
- Pages
- 515-522
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2011248911
- Cited by
- 112
- References
- 4
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.