Dilution and redistribution effects of rapid 2-litre infusions of 0.9% (w/v) saline and 5% (w/v) dextrose on haematological parameters and serum biochemistry in normal subjects: a double-blind crossover study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Although hypoalbuminaemia after injury may result from increased vascular permeability, dilution secondary to crystalloid infusions may contribute significantly. In this double-blind crossover study, the effects of bolus infusions of crystalloids on serum albumin, haematocrit, serum and urinary biochemistry and bioelectrical impedance analysis were measured in healthy subjects. Ten male volunteers received 2-litre infusions of 0.9% (w/v) saline or 5% (w/v) dextrose over 1 h; infusions were carried out on separate occasions, in random order. Weight, haemoglobin, serum albumin, serum and urinary biochemistry and bioelectrical impedance were measured pre-infusion and hourly for 6 h. The serum albumin concentration fell in all subjects (20% after saline; 16% after dextrose) by more than could be explained by dilution alone. This fall lasted more than 6 h after saline infusion, but values had returned to baseline 1 h after the end of the dextrose infusion. Changes in haematocrit and haemoglobin were less pronounced (7.5% after saline; 6.5% after dextrose). Whereas all the water from dextrose was excreted by 2 h after completion of the infusion, only one-third of the sodium and water from the saline had been excreted by 6 h, explaining its persistent diluting effect. Impedances rose after dextrose and fell after saline (P < 0.001). Subjects voided more urine (means 1663 and 563 ml respectively) of lower osmolality (means 129 and 630 mOsm/kg respectively) and sodium content (means 26 and 95 mmol respectively) after dextrose than after saline (P < 0.001). While an excess water load is excreted rapidly, an excess sodium load is excreted very slowly, even in normal subjects, and causes persistent dilution of haematocrit and serum albumin. The greater than expected change in serum albumin concentration when compared with that of haemoglobin suggests that, while dilution is responsible for the latter, redistribution also has a role in the former. Changes in bioelectrical impedance may reflect the electrolyte content rather than the volume of the infusate, and may be unreliable for clinical purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
INCREASED VASCULAR PERMEABILITY: A MAJOR CAUSE OF HYPOALBUMINAEMIA IN DISEASE AND INJURY
Fleck, A., Hawker, F., Wallace, P. I., Raines, G., Trotter, J., Ledingham, I. M., & Calman, K. C. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91447-3 · Cited by 898
Cited by
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Lobo, D. N., Bostock, K. A., Neal, K. R., Perkins, A. C., Rowlands, B. J., & Allison, S. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08711-1 · Cited by 1,038
Self-citationEffect of Intraoperative Fluid Management on Outcome after Intraabdominal Surgery
Nisanevich, V., Felsenstein, I., Almogy, G., Weissman, C., Einav, S., & Matot, I. (2005) · Anesthesiology · doi:10.1097/00000542-200507000-00008 · Cited by 864
Chowdhury, A. H., Cox, E. F., Francis, S. T., & Lobo, D. N. (2012) · Annals of Surgery · doi:10.1097/sla.0b013e318256be72 · Cited by 764
Self-citationFeldheiser, A., Aziz, O., Baldini, G., Cox, B. P. B. W., Fearon, K. C. H., Feldman, L. S., Gan, T. J., Kennedy, R. H., Ljungqvist, O., Lobo, D. N., et al. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12651 · Cited by 714
Self-citation
Metadata
- Authors
- LOBO, D. N., STANGA, Z., SIMPSON, J. A. D., ANDERSON, J. A., ROWLANDS, B. J., & ALLISON, S. P.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 2001-07-17
- Volume
- 101
- Issue
- 2
- Pages
- 173-179
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2077173768
- Cited by
- 143
- References
- 1
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.