CoChat

Short- and long-term reproducibility of autonomic measures in supine and standing positions

KOWALEWSKI, M. A., URBAN, M. · 2004 · Clinical Science
Cited by 54

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Autonomic nervous tests and heart rate variability (HRV) have been used to assess cardiac autonomic function and to evaluate long-term prognosis. The aim of this study was to evaluate the short- and long-term reproducibility of HRV parameters and autonomic nervous tests according to body position (supine or standing). The study group consisted of 26 healthy subjects. Autonomic nervous tests and HRV were performed twice during the day and the results were averaged. The protocol was then repeated 3 days after each examination and also after 6 and 24 months. Autonomic nervous tests included deep breathing, Valsalva manoeuvre and isometric muscle exercise (handgrip), as well as blood pressure and heart rate in response to standing. ECG recordings were taken for 10 min during spontaneous breathing for HRV analysis. We found that the reproducibility of some parameters of the autonomic nervous test were independent of body position [E/I ratio (heart rate response to deep breathing)], whereas other parameters were dependent on body position (Valsalva manoeuvre and blood pressure response to sustained handgrip). In addition, within-day measurements of those parameters varied from non-reproducible (Valsalva ratio, handgrip and blood pressure response to standing) to moderately reproducible [E/I ratio and 30/15 ratio (heart rate response to standing)]. Among the HRV parameters, we found that total power (TP), low (LF)- and high (HF)-frequency were reproducible not only for measurements made within the same day, but also during short- and long-term observations, and only the LF/HF ratio was dependent on body position. We conclude that only a few autonomic nervous tests are reproducible in the short- and long-term. Because HRV parameters obtained during spontaneous respiration showed high reproducibility for measurements made within the same day as well as in the short- and long-term, they should be used instead of autonomic nervous tests when long-term observations are carried out in a healthy population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs20030119

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
KOWALEWSKI, M. A., & URBAN, M.
Venue
Clinical Science
Published
2004-01-01
Volume
106
Issue
1
Pages
61-66
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2030517247
Cited by
54
References
3
FWCI
1.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.