Guidelines for Selecting Microphones for Human Voice Production Research
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Purpose: This tutorial addresses fundamental characteristics of microphones (frequency response, frequency range, dynamic range, and directionality), which are important for accurate measurements of voice and speech. Method: Technical and voice literature was reviewed and analyzed. The following recommendations on desirable microphone characteristics were formulated: The frequency response of microphones should be flat (i.e., variation of less than 2 dB) within the frequency range between the lowest expected fundamental frequency of voice and the highest spectral component of interest. The equivalent noise level of the microphones is recommended to be at least 15 dB lower than the sound level of the softest phonations. The upper limit of the dynamic range of the microphone should be above the sound level of the loudest phonations. Directional microphones should be placed at the distance that corresponds to their maximally flat frequency response, to avoid the proximity effect; otherwise, they will be unsuitable for spectral and level measurements. Numerical values for these recommendations were derived for the microphone distances of 30 cm and 5 cm. Conclusions: The recommendations, while preliminary and in need of further numerical justification, should provide the basis for better accuracy and repeatability of studies on voice and speech production in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,804
Clinical measurement of speech and voice
Baken, R. J. (1987) · Cited by 1,465
Dejonckere, P. H., Bradley, P., Clemente, P., Cornut, G., Crevier-Buchman, L., Friedrich, G., Van De Heyning, P., Remacle, M., & Woisard, V. (2001) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050000299 · Cited by 1,161
A new inverse-filtering technique for deriving the glottal air flow waveform during voicing
Rothenberg, M. (1973) · The Journal of the Acoustical Society of America · doi:10.1121/1.1913513 · Cited by 371
Acoustic Measures and Self-reports of Vocal Fatigue by Female Teachers
Laukkanen, A.-M., Ilomäki, I., Leppänen, K., & Vilkman, E. (2008) · Journal of Voice · doi:10.1016/j.jvoice.2006.10.001 · Cited by 229
Schutte, H. K., & Seidner, W. (1983) · Folia Phoniatrica et Logopaedica · doi:10.1159/000265703 · Cited by 225
Some Technical Considerations in Voice Perturbation Measurements
Titze, I. R., Horii, Y., & Scherer, R. C. (1987) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jshr.3002.252 · Cited by 182
Effect of Microphone Type and Placement on Voice Perturbation Measurements
Titze, I. R., & Winholtz, W. S. (1993) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jshr.3606.1177 · Cited by 158
Differences in phonetogram features between male and female subjects with and without vocal training
Sulter, A. M., Schutte, H. K., & Miller, D. G. (1995) · Journal of Voice · doi:10.1016/s0892-1997(05)80198-5 · Cited by 148
Acoustic model and evaluation of pathological voice production
Deliyski, D. D. (1993) · 3rd European Conference on Speech Communication and Technology (Eurospeech 1993) · doi:10.21437/eurospeech.1993-445 · Cited by 138
Acoustic analysis and synthesis of speech with applications to Swedish
Fant, G. (1959) · Americanae (AECID Library) · Cited by 122
Björkner, E. (2007) · Journal of Voice · doi:10.1016/j.jvoice.2006.12.007 · Cited by 117
Ilomäki, I., Laukkanen, A.-M., Leppänen, K., & Vilkman, E. A. (2008) · Logopedics Phoniatrics Vocology · doi:10.1080/14015430701864822 · Cited by 110
Vocal fold physiology: Controlling complexity and chaos
Davis, P. J., & Fletcher, N. H. (1996) · ANU Open Research (Australian National University) · Cited by 101
Exploration of Pressure Field Around the Human Head During Speech
Dunn, H. K., & Farnsworth, D. W. (1939) · The Journal of the Acoustical Society of America · doi:10.1121/1.1915975 · Cited by 100
Regression Tree Approach to Studying Factors Influencing Acoustic Voice Analysis
Deliyski, D. D., Shaw, H. S., Evans, M. K., & Vesselinov, R. (2006) · Folia Phoniatrica et Logopaedica · doi:10.1159/000093184 · Cited by 95
Acoustic waveform perturbations and voice disorders
Laver, J., Hiller, S. M., & Beck, J. M. (1992) · Journal of Voice · doi:10.1016/s0892-1997(05)80125-0 · Cited by 84
Tokuda, I. T., Horáček, J., Švec, J. G., & Herzel, H. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2741210 · Cited by 80
Reliability of Speaking and Maximum Voice Range Measures in Screening for Dysphonia
Ma, E., Robertson, J., Radford, C., Vagne, S., El-Halabi, R., & Yiu, E. M. ‐. (2006) · Journal of Voice · doi:10.1016/j.jvoice.2006.03.004 · Cited by 73
A Subharmonic Vibratory Pattern in Normal Vocal Folds
Švec, J. G., Schutte, H. K., & Miller, D. G. (1996) · Journal of Speech Language and Hearing Research · doi:10.1044/jshr.3901.135 · Cited by 63
Nonlinear phenomena in contemporary vocal music
Neubauer, J., Edgerton, M. E., & Herzel, H. (2004) · Journal of Voice · doi:10.1016/s0892-1997(03)00073-0 · Cited by 61
Frøkjær-Jensen, B., & Prytz, S. (1975) · Annual Report of the Institute of Phonetics University of Copenhagen · doi:10.7146/aripuc.v9i.130977 · Cited by 59
Acoustic and Perceptual Indicators of Normal and Pathological Voice
Muñoz, J., Mendoza, E., Fresneda, M. D., Carballo, G., & López, P. (2003) · Folia Phoniatrica et Logopaedica · doi:10.1159/000070092 · Cited by 52
Assessment of Vocal Capacity of Finnish University Students
Leino, T., Laukkanen, A.-M., Ilomäki, I., & Mäki, E. (2008) · Folia Phoniatrica et Logopaedica · doi:10.1159/000133651 · Cited by 33
The clinical utility of the soft phonation index
Roussel, N. C., & Lobdell, M. (2006) · Clinical Linguistics & Phonetics · doi:10.1080/02699200400026942 · Cited by 30
Relation between perceived voice register and flow glottogram parameters in males
Salomão, G. L., & Sundberg, J. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2924146 · Cited by 27
Monopitched Expression of Emotions in Different Vowels
Waaramaa, T., Laukkanen, A.-M., Alku, P., & Väyrynen, E. (2008) · Folia Phoniatrica et Logopaedica · doi:10.1159/000151762 · Cited by 26
Effects of environmental noise on computer-derived voice estimates from female speakers
Perry, C. K., Ingrisano, D., Palmer, M. A., & McDonald, E. J. (2000) · Journal of Voice · doi:10.1016/s0892-1997(00)80021-1 · Cited by 24
Miniature Head-Mounted Microphone for Voice Perturbation Analysis
Winholtz, W. S., & Titze, I. R. (1997) · Journal of Speech Language and Hearing Research · doi:10.1044/jslhr.4004.894 · Cited by 22
Cited by
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Clinical Practice Guideline: Improving Voice Outcomes after Thyroid Surgery
Chandrasekhar, S. S., Randolph, G. W., Seidman, M. D., Rosenfeld, R. M., Angelos, P., Barkmeier‐Kraemer, J., Benninger, M. S., Blumin, J. H., Dennis, G., Hanks, J., et al. (2013) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599813487301 · Cited by 466
Maryn, Y., & Weenink, D. (2015) · Journal of Voice · doi:10.1016/j.jvoice.2014.06.015 · Cited by 271
Assessment of voice quality: Current state-of-the-art
Barsties, B., & De Bodt, M. (2015) · Auris Nasus Larynx · doi:10.1016/j.anl.2014.11.001 · Cited by 265
Leung, Y., Oates, J., & Chan, S. P. (2018) · Journal of Speech, Language, and Hearing Research · doi:10.1044/2017_jslhr-s-17-0067 · Cited by 190
“No characteristics reported Reported, but does not meet recommendations of Svec & Granqvist (2010) Microphone has flat frequency response, equivalent noise level at least 15 dB below softest phonation, upper limit of dynamic range above loudest phonation (Svec & Granqvist, 2010) Sampling rate —”
Background
Metadata
- Authors
- Švec, J. G., & Granqvist, S.
- Venue
- American Journal of Speech-Language Pathology
- Published
- 2010-11
- Volume
- 19
- Issue
- 4
- Pages
- 356-368
- ISSN
- 1058-0360 (ISSN-L)
- 1558-9110
- DOI
- 10.1044/1058-0360(2010/09-0091
- OpenAlex
- W2074875921
- Cited by
- 191
- References
- 30
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.