Use of an Anatomical Scalar to Control for Sex-Based Size Differences in Measures of Hyoid Excursion During Swallowing
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: Traditional methods for measuring hyoid excursion from dynamic videofluoroscopy recordings involve calculating changes in position in absolute units (mm). This method shows a high degree of variability across studies but agreement that greater hyoid excursion occurs in men than in women. Given that men are typically taller than women, the authors hypothesized that controlling for participant size might neutralize apparent sex-based differences in hyoid excursion. Method: Hyoid excursion in 20 young (<45) healthy volunteers (10 male), stratified by height, was measured in a tightly controlled videofluoroscopic protocol. Results: The study identified an anatomical scalar (C2–C4 length), visible on the videofluoroscopic image, correlated with participant height. This scalar differed significantly between men and women. By incorporating the anatomical scalar as a continuous covariate in repeated measures mixed-model analyses of variance of hyoid excursion, apparent sex-based differences were neutralized. Transforming measures of hyoid excursion into anatomically scaled units achieved the same result, reducing variation attributable to sex-based differences in participant size. Conclusions: Hyoid excursion during swallowing is dependent on a person's size. If measurements do not control for this source of variation, apparent sex differences in hyoid excursion are seen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Test-retest variability in normal swallowing
Lof, G. L., & Robbins, J. (1990) · Dysphagia · doi:10.1007/bf02407271 · Cited by 133 · cited 1×
“A protocol of three repetitions per volume condition was used to ensure representative sampling of intraparticipant variability, while keeping radiation exposure time to a minimum (Lof & Robbins, 1990).”
Cited by
Reference values for healthy swallowing across the range from thin to extremely thick liquids
Steele, C. M., Peladeau-Pigeon, M., Barbon, C. A. E., Guida, B. T., Namasivayam-MacDonald, A. M., Nascimento, W. V., Smaoui, S., Tapson, M. S., Valenzano, T. J., Waito, A. A., et al. (2019) · Journal of Speech, Language, and Hearing Research · doi:10.1044/2019_jslhr-s-18-0448 · Cited by 180
“The diameter of UESO was traced (in pixels) on the frame of UESMax, relative to the length of an anatomical scalar (length of the cervical spine between the anterior inferior corners of the C2 and C4 vertebrae; Molfenter & Steele, 2014).”
MethodInfluentialSelf-citationAutomatic annotation of cervical vertebrae in videofluoroscopy images via deep learning
Zhang, Z., Mao, S., Coyle, J., & Sejdić, E. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102218 · Cited by 18
Donohue, C., Khalifa, Y., Mao, S., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Journal of Speech, Language, and Hearing Research · doi:10.1044/2021_jslhr-21-00134 · Cited by 15
“Spatial swallow kinematic measurements were scaled to an anatomical scalar (length of C2–C4) to control for participant size (Brates et al., 2019; Molfenter & Steele, 2014).”
Method
Metadata
- Authors
- Molfenter, S. M., & Steele, C. M.
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 2014-06
- Volume
- 57
- Issue
- 3
- Pages
- 768-778
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W2040526597
- Cited by
- 97
- References
- 1
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of an Anatomical Scalar to Control for Sex-Based Size Differences in Measures of Hyoid Excursion During Swallowing. https://app.cochat.ai/papers/10.1044/2014_jslhr-s-13-0152
- The paper
- Molfenter, S. M., & Steele, C. M. (2014). Use of an Anatomical Scalar to Control for Sex-Based Size Differences in Measures of Hyoid Excursion During Swallowing. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/2014_jslhr-s-13-0152
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.