CoChat

Reference Values for Healthy Swallowing Across the Range From Thin to Extremely Thick Liquids

Open access
Steele, Catriona M., Peladeau-Pigeon, Melanie, Barbon, Carly A. E., Guida, Brittany T., Namasivayam-MacDonald, Ashwini M., Nascimento, Weslania V., Smaoui, Sana, Tapson, Melanie S., Valenzano, Teresa J., Waito, Ashley A., Wolkin, Talia S. · 2019 · Journal of Speech, Language, and Hearing Research

The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.

Abstract

Purpose: Thickened liquids are frequently used as an intervention for dysphagia, but gaps persist in our understanding of variations in swallowing behavior based on incremental thickening of liquids. The goal of this study was to establish reference values for measures of bolus flow and swallowing physiology in healthy adults across the continuum from thin to extremely thick liquids. Method: A sex-balanced sample of 38 healthy adults underwent videofluoroscopy and swallowed 20% weight-to-volume concentration barium prepared in thin and slightly, mildly, moderately, and extremely thick consistencies using a xanthan gum thickener. Participants took comfortable sips and swallowed without a cue; sip volume was measured based on presip and postsip cup weights. A standard operating procedure (the ASPEKT method: Analysis of Swallowing Physiology: Events, Kinematics and Timing) was used to analyze videofluoroscopy recordings. Results: The results clarify that, for thin liquid sips (10–14 ml), a single swallow without clearing swallows is typical and is characterized by complete laryngeal vestibule closure, complete pharyngeal constriction, and minimal postswallow residue. Aspiration was not seen, and penetration was extremely rare. Bolus position at swallow onset was variable, extending as low as the pyriform sinuses in 37% of cases. With thicker liquids, no changes in event sequencing, laryngeal vestibule closure, pharyngeal constriction, or postswallow residue were seen. The odds of penetration were significantly reduced. A longer timing interval until onset of the hyoid burst movement was seen, with an associated higher bolus position at swallow onset. Other timing measures remained unaffected by changes in bolus consistency. Conclusion: The results include new reference data for swallowing in healthy adults across the range from thin to extremely thick liquids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1044/2019_jslhr-s-18-0448

Cites

83 of 83 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Stimulus array used in the current experiment. A 20% w/v barium sulfate suspension (thin) was mixed with a xanthan gum thickener to reach Levels 1–4 of the International Dysphagia Diet Standardisation Initiative framework.
Figure 1. Stimulus array used in the current experiment. A 20% w/v barium sulfate suspension (thin) was mixed with a xanthan gum thickener to reach Levels 1–4 of the International Dysphagia Diet Standardisation Initiative framework.CC BY-NC-SA · PubMed Central
Figure 2. Sip volume by consistency, in descending order of volume. Sip volumes for slightly and mildly thick liquids were significantly smaller (p < .001) than those for thin liquids. A further significant reduction in sip volume was seen with moderately and extremely thick liquids, which were served by a teaspoon. IDDSI = International Dysphagia Diet Standardisation Initiative.
Figure 2. Sip volume by consistency, in descending order of volume. Sip volumes for slightly and mildly thick liquids were significantly smaller (p < .001) than those for thin liquids. A further significant reduction in sip volume was seen with moderately and extremely thick liquids, which were served by a teaspoon. IDDSI = International Dysphagia Diet Standardisation Initiative.CC BY-NC-SA · PubMed Central
Figure 3. The effect of liquid consistency on swallow reaction time (i.e., the interval between the bolus passing the ramus of mandible and onset of the hyoid burst). Significantly longer swallow reaction times were seen with the moderately and extremely thick liquids (p < .001). IDDSI = International Dysphagia Diet Standardisation Initiative.
Figure 3. The effect of liquid consistency on swallow reaction time (i.e., the interval between the bolus passing the ramus of mandible and onset of the hyoid burst). Significantly longer swallow reaction times were seen with the moderately and extremely thick liquids (p < .001). IDDSI = International Dysphagia Diet Standardisation Initiative.CC BY-NC-SA · PubMed Central
Figure 4. The effect of liquid consistency on laryngeal vestibule closure reaction time (i.e., the interval between onset of the hyoid burst and the frame of laryngeal vestibule closure). Significantly longer Laryngeal Vestibule Closure Reaction Times (p < .001) were seen with the moderately and extremely thick liquids compared to the thin and slightly thick stimuli. IDDSI = International Dysphagia Diet Standardisation Initiative; LVCRT = Laryngeal Vestibule Closure Reaction Time.
Figure 4. The effect of liquid consistency on laryngeal vestibule closure reaction time (i.e., the interval between onset of the hyoid burst and the frame of laryngeal vestibule closure). Significantly longer Laryngeal Vestibule Closure Reaction Times (p < .001) were seen with the moderately and extremely thick liquids compared to the thin and slightly thick stimuli. IDDSI = International Dysphagia Diet Standardisation Initiative; LVCRT = Laryngeal Vestibule Closure Reaction Time.CC BY-NC-SA · PubMed Central
Figure A1. Overview of the ASPEKT rating method.
Figure A1. Overview of the ASPEKT rating method.CC BY-NC-SA · PubMed Central
Figure A2. Image showing the coordinate system used for pixel-based measurements, with the origin located at the anterior–inferior corner of the C4 vertebra, the y-axis defined by the C2–C4 cervical spine, and the x-axis derived at 90° to the y-axis. The red dashed line between the anterior–inferior corners of the C2 and C4 vertebrae is used as an anatomical reference scalar.
Figure A2. Image showing the coordinate system used for pixel-based measurements, with the origin located at the anterior–inferior corner of the C4 vertebra, the y-axis defined by the C2–C4 cervical spine, and the x-axis derived at 90° to the y-axis. The red dashed line between the anterior–inferior corners of the C2 and C4 vertebrae is used as an anatomical reference scalar.CC BY-NC-SA · PubMed Central
Figure A3. Image showing measurement of peak hyoid position in X, Y, and XY planes of movement relative to the anterior–inferior corner of the C4 vertebra. The red dashed line between the anterior–inferior corners of the C2 and C4 vertebra is used as an anatomical reference scalar.
Figure A3. Image showing measurement of peak hyoid position in X, Y, and XY planes of movement relative to the anterior–inferior corner of the C4 vertebra. The red dashed line between the anterior–inferior corners of the C2 and C4 vertebra is used as an anatomical reference scalar.CC BY-NC-SA · PubMed Central
Figure A4. Image showing measurement of the maximum upper esophageal sphincter distension. The red dashed line between the anterior–inferior corners of the C2 and C4 vertebrae is used as an anatomical reference scalar.
Figure A4. Image showing measurement of the maximum upper esophageal sphincter distension. The red dashed line between the anterior–inferior corners of the C2 and C4 vertebrae is used as an anatomical reference scalar.CC BY-NC-SA · PubMed Central
Figure A5. Image showing measurement of the pharyngeal area at rest. The red dashed lines illustrate the squared C2 and C4 reference area that is used as an anatomical reference scalar.
Figure A5. Image showing measurement of the pharyngeal area at rest. The red dashed lines illustrate the squared C2 and C4 reference area that is used as an anatomical reference scalar.CC BY-NC-SA · PubMed Central
Figure A6. Image showing measurement of the unobligated pharyngeal area on the frame of maximum pharyngeal constriction. The red dashed lines illustrate the squared C2 and C4 reference area that is used as an anatomical reference scalar.
Figure A6. Image showing measurement of the unobligated pharyngeal area on the frame of maximum pharyngeal constriction. The red dashed lines illustrate the squared C2 and C4 reference area that is used as an anatomical reference scalar.CC BY-NC-SA · PubMed Central
Figure A7. Image of a swallow rest frame with residue located in both the valleculae and pyriform sinuses.
Figure A7. Image of a swallow rest frame with residue located in both the valleculae and pyriform sinuses.CC BY-NC-SA · PubMed Central
Figure A8. Tracings of residue area relative to spatial housing in the valleculae and pyriform sinuses. Residue area can also be expressed relative to the squared C2–C4 reference scalar illustrated by the red dashed lines.
Figure A8. Tracings of residue area relative to spatial housing in the valleculae and pyriform sinuses. Residue area can also be expressed relative to the squared C2–C4 reference scalar illustrated by the red dashed lines.CC BY-NC-SA · PubMed Central
Figure A9. Tracing of additional residue in the area between the valleculae and pyriform sinuses. Tracings of additional residue can be added to tracings of vallecular and pyriform sinus residue for a total pharyngeal area measure, with all subcomponents expressed relative to the squared C2–C4 reference scalar illustrated by the red dashed lines.
Figure A9. Tracing of additional residue in the area between the valleculae and pyriform sinuses. Tracings of additional residue can be added to tracings of vallecular and pyriform sinus residue for a total pharyngeal area measure, with all subcomponents expressed relative to the squared C2–C4 reference scalar illustrated by the red dashed lines.CC BY-NC-SA · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 83 references

Research works printed but not linked: 14

  1. American Dietetic Association, 2002, National dysphagia diet: Standardization for optimal care
  2. Kotrlik J. W., 2003, The incorporation of effect size in informaton technology, learning, and performance research, Information Technology, Learning, and Performance Journal, 21, 1
  3. Mayer J., 2018, Effects of recording rate, screen calibration, and room ambient lighting on videofluoroscopic swallow study outcomes
  4. Péladeau-Pigeon M., 2013, Technical aspects of a videofluoroscopic swallowing study, Canadian Journal of Speech-Language Pathology and Audiology, 37, 216
  5. Steele C. M., 2015, Poster #97: Variations in sip volume as a function of pre-sip cup volume
  6. Leonard R. J., 2017, Two methods for quantifying pharyngeal residue on fluoroscopic swallow studies: Reliability assessment, Annals of Otolaryngology and Rhinology, 4, 1168
  7. 10.1007/s00455-008-9185-9 · DOI · Paper page
  8. 10.1044/2014_jslhr-s-13-0152 · DOI · Paper page
  9. 10.1007/s00455-013-9456-y · DOI
  10. 10.1155/2014/738971 · DOI
  11. 10.1007/s00455-012-9426-9 · DOI · Paper page
  12. 10.1044/jshr.3803.579 · DOI
  13. 10.1016/0016-5085(92)90013-o · DOI · Paper page
  14. 10.1007/bf00417897 · DOI · Paper page

Cited by

See all 192

Metadata

Authors
Steele, C. M., Peladeau-Pigeon, M., Barbon, C. A. E., Guida, B. T., Namasivayam-MacDonald, A. M., Nascimento, W. V., Smaoui, S., Tapson, M. S., Valenzano, T. J., Waito, A. A., & Wolkin, T. S.
Affiliations
  • University Health Network (CA)
  • Swallowing Rehabilitation Research Laboratory, Toronto Rehabilitation Institute, University Health Network, Ontario, Canada
Corresponding author
Steele, Catriona M.
Venue
Journal of Speech, Language, and Hearing Research
Published
2019-05-21
Volume
62
Issue
5
Pages
1338-1363
ISSN
  • 1092-4388 (ISSN-L)
  • 1558-9102
OpenAlex
W2941467565
Cited by
180
References
83
Citations by year
2026: 15 · 2025: 24 · 2024: 27 · 2023: 27 · 2022: 32 · 2021: 30 · 2020: 18 · 2019: 5
FWCI
35.91
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Journal of Speech Language and Hearing Research (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-sa)
  • PubMed Central (publishedVersion, cc-by-nc-sa)
  • PubMed (publishedVersion)
  • MacSphere (McMaster University) (submittedVersion)
  • MacSphere (McMaster University)
Funders
  • National Institute on Aging (R01AG077481)
  • National Institute on Deafness and Other Communication Disorders (R01DC011020)
Topics
  • Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
  • Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
  • Health Sciences › Medicine › Otorhinolaryngology › Head and Neck Cancer Studies
Keywords
swallowing physiology, thickened liquids, bolus flow, dysphagia, bolus consistency, laryngeal vestibule closure, pharyngeal constriction, penetration, aspiration, reference values, videofluoroscopy
MeSH terms
Adult, Barium Sulfate, Contrast Media, Deglutition, Female, Food Additives, Humans, Male, Middle Aged, Polysaccharides, Bacterial, Reference Values, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reference Values for Healthy Swallowing Across the Range From Thin to Extremely Thick Liquids. https://app.cochat.ai/papers/10.1044/2019_jslhr-s-18-0448
The paper
Steele, C. M., Peladeau-Pigeon, M., Barbon, C. A. E., Guida, B. T., Namasivayam-MacDonald, A. M., Nascimento, W. V., Smaoui, S., Tapson, M. S., Valenzano, T. J., Waito, A. A., & Wolkin, T. S. (2019). Reference Values for Healthy Swallowing Across the Range From Thin to Extremely Thick Liquids. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/2019_jslhr-s-18-0448

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.