Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech
The DOI matches its Crossref record; 32 of the 35 references it cites were found in a registry or an index.
Abstract
Purpose: Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Method: Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Results: Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. Conclusions: SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Calibration was performed using sustained ‘Ah’ vowels over ≥ 4 s following recommended procedures [34] and guidelines [35], with each recording including a reference reading from the sound level meter, recorded on an A-weighted scale [34].”
From Comparing face-to-face and online LSVT®LOUD speech training using LSVT®Coach in patients with Parkinson’s disease: a pilot randomised controlled trial (2025) · cites this paper as [34]
Citations
Cites
Praat: Doing Phonetics by Computer
(2011) · Ear & Hearing · doi:10.1097/aud.0b013e31821473f7 · Cited by 7,863
Dejonckere, P. H., Bradley, P., Clemente, P., Cornut, G., Crevier-Buchman, L., Friedrich, G., Van De Heyning, P., Remacle, M., & Woisard, V. (2001) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050000299 · Cited by 1,161
Kuttruff, H. (1973) · Cited by 1,120
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Self-citationDreschler, W. A., Verschuure, H., Ludvigsen, C., & Westermann, S. (2001) · International Journal of Audiology · doi:10.3109/00206090109073110 · Cited by 320
Evaluation of smartphone sound measurement applications
Kardous, C. A., & Shaw, P. B. (2014) · The Journal of the Acoustical Society of America · doi:10.1121/1.4865269 · Cited by 312
Vocal Dose Measures: Quantifying Accumulated Vibration Exposure in Vocal Fold Tissues
Titze, I. R., Švec, J. G., & Popolo, P. S. (2003) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2003/072 · Cited by 252
Self-citationSchutte, H. K., & Seidner, W. (1983) · Folia Phoniatrica et Logopaedica · doi:10.1159/000265703 · Cited by 225
Howard, D., & Angus, J. (2000) · Routledge eBooks · doi:10.4324/9780080498522 · Cited by 210
Adverse Effects of Environmental Noise on Acoustic Voice Quality Measurements
Deliyski, D. D., Shaw, H. S., & Evans, M. K. (2005) · Journal of Voice · doi:10.1016/j.jvoice.2004.07.003 · Cited by 199
Research works printed but not linked: 25
- ANSI, 1994, ANSI S1.1-1994 (R2004). American National Standard. Acoustical terminology
- ANSI, 2006, ANSI S1.40-2006. American National Standard. Specifications and verification procedures for sound calibrators
- ANSI, 2006, ANSI S3.44-1996 (R2006). American National Standard. Determination of occupational noise exposure and estimation of noise-induced hearing impairment
- ANSI, 2008, ANSI/ASA S12.9-2008/Part 6. American National Standard. Quantities and procedures for description and measurement of environmental sound—Part 6: Methods for estimation of awakenings associated with outdoor noise events heard in homes
- ANSI, 2010, ANSI/ASA S12.60-2010/Part 1. American National Standard. Acoustical performance criteria, design requirements, and guidelines for schools, Part 1: Permanent schools
- ANSI, 2014, ANSI/ASA S1.4 PART 1 2014 Edition. American National Standard. Electroacoustics—Sound level meters—Part 1: Specifications
- Brixen E. B., 1998, Near field registration of the human voice: Spectral changes due to positions (Paper no. 4728)
- Brüel & Kjaer, 1984, Measuring sound
- Cabrera D., 2002, Recording the operatic voice for acoustic analysis, Acoustics Australia, 30, 103
- Cohen E. R., 1987, Symbols, units, nomenclature and fundamental constants in physics. Document I.U.P.A.P.-25 (SUNAMCO 87-1)
- EPA, 1979, EPA/550/9-79-100. Protective noise levels. Condensed version of “Information on levels of environmental noise requisite to protect public health and welfare with an adequate margin of safety, EPA/ONAC 550/9-74-004.”
- Everest F. A., 2001, Master handbook of acoustics
- Howard D. M., 2001, Occupational voice—Care and cure, 29
- IEC, 2003, IEC 60942 ed. 3.0. Electroacoustics—Sound calibrators
- IEC, 2013, IEC 61672-1:2013. Electroacoustics—Sound level meters—Part 1: Specification
- ISO, 2003, ISO 9921:2003(E). Ergonomics—Assessment of speech communication
- ISO, 2007, ISO 80000-8:2007. Quantities and units—Part 8: Acoustics
- ISO, 2007, ISO/TR 25417:2007. Acoustics—Definitions of basic quantities and terms
- Kardous C. A., 2015, Do sound meter apps measure noise levels accurately?, Sound and Vibration, July, 2015, 10
- Liljencrants J., 2004, Elektroakustik [Electroacoustics] (In Swedish). TRITA-TMH 2004-3
- NIOSH, 1998, Criteria for a recommended standard: Occupational noise exposure. Publication No. 98-126
- Pabon P., 2007, Voice profiler (version 4.0)
- Pearsons K., 1976, Speech levels in various noise environments (Rep. No. EPA-600/1-77-02)
- Šrámková H., 2011, Měření dynamického rozsahu lidského hlasu [Measurements of dynamic range of human voice], Akustické listy, 17, 11
- Titze I. R., 2000, Principles of voice production (second printing)
Cited by
Patel, R. R., Awan, S. N., Barkmeier-Kraemer, J., Courey, M., Deliyski, D., Eadie, T., Paul, D., Švec, J. G., & Hillman, R. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0009 · Cited by 818
Self-citationGuidelines for Speech Recording and Acoustic Analyses in Dysarthrias of Movement Disorders
Rusz, J., Tykalova, T., Ramig, L. O., & Tripoliti, E. (2021) · Movement Disorders · doi:10.1002/mds.28465 · Cited by 170
Review of Recent Development of MEMS Speakers
Wang, H., Ma, Y., Zheng, Q., Cao, K., Lu, Y., & Xie, H. (2021) · Micromachines · doi:10.3390/mi12101257 · Cited by 114
Cepstral and Perceptual Investigations in Female Teachers With Functionally Healthy Voice
Phadke, K. V., Laukkanen, A.-M., Ilomäki, I., Kankare, E., Geneid, A., & Švec, J. G. (2018) · Journal of Voice · doi:10.1016/j.jvoice.2018.09.010 · Cited by 111
Self-citationSound-based multiple-equipment activity recognition using convolutional neural networks
Sherafat, B., Rashidi, A., & Asgari, S. (2022) · Automation in Construction · doi:10.1016/j.autcon.2021.104104 · Cited by 59
Metadata
- Authors
- Švec, J. G., & Granqvist, S.
- Affiliations
- Palacký University Olomouc (CZ)
- Karolinska Institutet (SE)
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 2018-03-15
- Volume
- 61
- Issue
- 3
- Pages
- 441-461
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W2787946070
- Cited by
- 166
- References
- 35
- Citations by year
- 2026: 20 · 2025: 36 · 2024: 24 · 2023: 22 · 2022: 23 · 2021: 25 · 2020: 7 · 2019: 4 · 2018: 5
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Speech Language and Hearing Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
- Physical Sciences › Computer Science › Signal Processing › Speech and Audio Processing
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Phonetics and Phonology Research
- Keywords
- sound pressure level, voice, speech, sound level meter, microphone calibration, head-mounted microphone, frequency weighting, time weighting, background noise, measurement reproducibility
- MeSH terms
- Pressure, Speech, Speech Production Measurement, Voice, Practice Guidelines as Topic, Electrical Equipment and Supplies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech. https://app.cochat.ai/papers/10.1044/2017_jslhr-s-17-0095
- The paper
- Švec, J. G., & Granqvist, S. (2018). Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/2017_jslhr-s-17-0095
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.