CoChat

Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech

Švec, Jan G., Granqvist, Svante · 2018 · Journal of Speech, Language, and Hearing Research

The DOI matches its Crossref record; 32 of the 35 references it cites were found in a registry or an index.

Abstract

Purpose: Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Method: Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Results: Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. Conclusions: SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.

Overview

Integrity signals

Registry

Crossref · 10.1044/2017_jslhr-s-17-0095

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Research works printed but not linked: 25

  1. ANSI, 1994, ANSI S1.1-1994 (R2004). American National Standard. Acoustical terminology
  2. ANSI, 2006, ANSI S1.40-2006. American National Standard. Specifications and verification procedures for sound calibrators
  3. ANSI, 2006, ANSI S3.44-1996 (R2006). American National Standard. Determination of occupational noise exposure and estimation of noise-induced hearing impairment
  4. ANSI, 2008, ANSI/ASA S12.9-2008/Part 6. American National Standard. Quantities and procedures for description and measurement of environmental sound—Part 6: Methods for estimation of awakenings associated with outdoor noise events heard in homes
  5. ANSI, 2010, ANSI/ASA S12.60-2010/Part 1. American National Standard. Acoustical performance criteria, design requirements, and guidelines for schools, Part 1: Permanent schools
  6. ANSI, 2014, ANSI/ASA S1.4 PART 1 2014 Edition. American National Standard. Electroacoustics—Sound level meters—Part 1: Specifications
  7. Brixen E. B., 1998, Near field registration of the human voice: Spectral changes due to positions (Paper no. 4728)
  8. Brüel & Kjaer, 1984, Measuring sound
  9. Cabrera D., 2002, Recording the operatic voice for acoustic analysis, Acoustics Australia, 30, 103
  10. Cohen E. R., 1987, Symbols, units, nomenclature and fundamental constants in physics. Document I.U.P.A.P.-25 (SUNAMCO 87-1)
  11. EPA, 1979, EPA/550/9-79-100. Protective noise levels. Condensed version of “Information on levels of environmental noise requisite to protect public health and welfare with an adequate margin of safety, EPA/ONAC 550/9-74-004.”
  12. Everest F. A., 2001, Master handbook of acoustics
  13. Howard D. M., 2001, Occupational voice—Care and cure, 29
  14. IEC, 2003, IEC 60942 ed. 3.0. Electroacoustics—Sound calibrators
  15. IEC, 2013, IEC 61672-1:2013. Electroacoustics—Sound level meters—Part 1: Specification
  16. ISO, 2003, ISO 9921:2003(E). Ergonomics—Assessment of speech communication
  17. ISO, 2007, ISO 80000-8:2007. Quantities and units—Part 8: Acoustics
  18. ISO, 2007, ISO/TR 25417:2007. Acoustics—Definitions of basic quantities and terms
  19. Kardous C. A., 2015, Do sound meter apps measure noise levels accurately?, Sound and Vibration, July, 2015, 10
  20. Liljencrants J., 2004, Elektroakustik [Electroacoustics] (In Swedish). TRITA-TMH 2004-3
  21. NIOSH, 1998, Criteria for a recommended standard: Occupational noise exposure. Publication No. 98-126
  22. Pabon P., 2007, Voice profiler (version 4.0)
  23. Pearsons K., 1976, Speech levels in various noise environments (Rep. No. EPA-600/1-77-02)
  24. Šrámková H., 2011, Měření dynamického rozsahu lidského hlasu [Measurements of dynamic range of human voice], Akustické listy, 17, 11
  25. Titze I. R., 2000, Principles of voice production (second printing)

Cited by

See all 166

Metadata

Authors
Švec, J. G., & Granqvist, S.
Affiliations
  • Palacký University Olomouc (CZ)
  • Karolinska Institutet (SE)
Venue
Journal of Speech, Language, and Hearing Research
Published
2018-03-15
Volume
61
Issue
3
Pages
441-461
ISSN
  • 1092-4388 (ISSN-L)
  • 1558-9102
OpenAlex
W2787946070
Cited by
166
References
35
Citations by year
2026: 20 · 2025: 36 · 2024: 24 · 2023: 22 · 2022: 23 · 2021: 25 · 2020: 7 · 2019: 4 · 2018: 5
FWCI
1.35
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Speech Language and Hearing Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Speech and Hearing › Voice and Speech Disorders
  • Physical Sciences › Computer Science › Signal Processing › Speech and Audio Processing
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Phonetics and Phonology Research
Keywords
sound pressure level, voice, speech, sound level meter, microphone calibration, head-mounted microphone, frequency weighting, time weighting, background noise, measurement reproducibility
MeSH terms
Pressure, Speech, Speech Production Measurement, Voice, Practice Guidelines as Topic, Electrical Equipment and Supplies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech. https://app.cochat.ai/papers/10.1044/2017_jslhr-s-17-0095
The paper
Švec, J. G., & Granqvist, S. (2018). Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech. Journal of Speech, Language, and Hearing Research. https://doi.org/10.1044/2017_jslhr-s-17-0095

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.