The DOI matches its Crossref record.
Effect of Microphone Type and Placement on Voice Perturbation Measurements
Abstract
This study was conducted to explore the effects of microphone type (dynamic vs. condenser) and pattern (omnidirectional vs. cardioid) on the extraction of voice perturbation measures for sustained phonation. Also of interest were the effects of distance and angle between the source and the microphone. Four professional-grade and two consumer-grade microphones were selected for analysis. Synthesized phonation with different amplitude and frequency modulations at fundamental frequencies of 100 Hz and 300 Hz were presented over a loudspeaker. Human phonation was also included to test the validity of loudspeaker presentations. Three microphone distances (4 cm, 30 cm, 1 m) and three angles (0°, 45°, 90°) were used for microphone placement. Among the professional grade microphones, the cardioid condenser type had the smallest effect on perturbation measures. In general, condenser types gave better results than dynamic types. Microphones with an unbalanced output did not perform as well as those with balanced outputs. Microphone sensitivity and distance had the largest effect on perturbation measures, making it difficult to resolve normal vocal jitter at anything but a few centimeters from the mouth. Angle had little effect for short distances, but a greater effect for longer distances. These conclusions are preliminary because the sampling of microphones, distances, and signal types was very coarse. The study serves only to chart the course for future work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acoustic studies of dysarthric speech
Kent, R. D., Weismer, G., Kent, J. F., Vorperian, H. K., & Duffy, J. R. (1999) · Journal of Communication Disorders · doi:10.1016/s0021-9924(99)00004-0 · Cited by 284
Maryn, Y., & Weenink, D. (2015) · Journal of Voice · doi:10.1016/j.jvoice.2014.06.015 · Cited by 271
Assessment of voice quality: Current state-of-the-art
Barsties, B., & De Bodt, M. (2015) · Auris Nasus Larynx · doi:10.1016/j.anl.2014.11.001 · Cited by 265
Adverse Effects of Environmental Noise on Acoustic Voice Quality Measurements
Deliyski, D. D., Shaw, H. S., & Evans, M. K. (2005) · Journal of Voice · doi:10.1016/j.jvoice.2004.07.003 · Cited by 199
Factors affecting the quality of sound recording for speech and voice analysis
Vogel, A. P., & Morgan, A. T. (2009) · International Journal of Speech-Language Pathology · doi:10.3109/17549500902822189 · Cited by 61
Vogel, A. P., Rosen, K. M., Morgan, A. T., & Reilly, S. (2014) · Folia Phoniatrica et Logopaedica · doi:10.1159/000368227 · Cited by 44
Plug-and-Play Microphones for Recording Speech and Voice with Smart Devices
Noffs, G., Cobler-Lichter, M., Perera, T., Kolbe, S. C., Butzkueven, H., Boonstra, F. M. C., van der Walt, A., & Vogel, A. P. (2024) · Folia Phoniatrica et Logopaedica · doi:10.1159/000535152 · Cited by 5
“Increasing the distance between sound source and microphone makes the signal more susceptible to non-free fi eld in fl uences (e.g., re fl ection and refraction of sound in out-of-laboratory environments) [46], which in fl ates measurements related to noise and perturbation or distortion [22].”
Influential
Metadata
- Authors
- Titze, I. R., & Winholtz, W. S.
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 1993-12
- Volume
- 36
- Issue
- 6
- Pages
- 1177-1190
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W2026223107
- Cited by
- 158
- References
- 0
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.