The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The effects of digital anaesthesia on predictive grip force adjustments during vertical movements of a grasped object
Abstract
Grip force adjustments to fluctuations of inertial loads induced by vertical arm movements with a grasped object were analysed during normal and impaired finger sensibility. Normally grip force is modulated in a highly economical way in parallel with fluctuations of load force. Two subjects performed vertical up and down movements of a grasped object, both with normal finger sensibility and then cutaneously anaesthetized finger sensibility. Short breaks were taken in between single movements, during which the object was held stationary. After digital anaesthesia was applied to the grasping fingers, both subjects substantially increased the grip force. The grip force amplitude and timing still anticipated changes in load force, although the established grip force had already overcome movement‐induced load force peaks. This implies that the increase of grip force and consequently the elevated force ratio between maximum grip and maximum load force are not processed to alter the feedforward system of grip force control. Cutaneous afferent information from the grasping digits appears to be necessary for economic scaling of the grip force level, but it plays a subordinate role in the precise anticipatory temporal coupling of grip and load forces during voluntary object manipulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Factors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
Cited by
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Augurelle, A.-S., Smith, A. M., Lejeune, T., & Thonnard, J.-L. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00249.2002 · Cited by 330
Finger pad friction and its role in grip and touch
Adams, M. J., Johnson, S. A., Lefèvre, P., Lévesque, V., Hayward, V., André, T., & Thonnard, J.-L. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0467 · Cited by 293
Grip force control during object manipulation in cerebral stroke
Hermsdörfer, J., Hagl, E., Nowak, D. A., & Marquardt, C. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00042-7 · Cited by 262
Self-citationThe cutaneous contribution to adaptive precision grip
Witney, A. G., Wing, A., Thonnard, J.-L., & Smith, A. M. (2004) · Trends in Neurosciences · doi:10.1016/j.tins.2004.08.006 · Cited by 203
Metadata
- Authors
- Nowak, D. A., Hermsdörfer, J., Glasauer, S., Philipp, J., Meyer, L., & Mai, N.
- Venue
- European Journal of Neuroscience
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 14
- Issue
- 4
- Pages
- 756-762
- ISSN
- 0953-816X (ISSN-L)
- 1460-9568
- OpenAlex
- W2146206994
- Cited by
- 164
- References
- 1
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effects of digital anaesthesia on predictive grip force adjustments during vertical movements of a grasped object. https://app.cochat.ai/papers/10.1046/j.0953-816x.2001.01697.x
- The paper
- Nowak, D. A., Hermsdörfer, J., Glasauer, S., Philipp, J., Meyer, L., & Mai, N. (2001). The effects of digital anaesthesia on predictive grip force adjustments during vertical movements of a grasped object. European Journal of Neuroscience. https://doi.org/10.1046/j.0953-816x.2001.01697.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.