Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 330

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Importance of Cutaneous Feedback in Maintaining a Secure Grip During Manipulation of Hand-Held Objects

Augurelle, Anne-Sophie, Smith, Allan M., Lejeune, Thierry, Thonnard, Jean-Louis·2003·Journal of Neurophysiology

Abstract

Previous research has shown that grip and load forces are modulated simultaneously during manipulation of a hand-held object. This close temporal coupling suggested that both forces are controlled by an internal model within the CNS that predicts the changes in tangential force on the fingers. The objective of the present study was to examine how the internal model would compensate for the loss of cutaneous sensation through local anesthesia of the index and thumb. Ten healthy adult subjects (5 men and 5 women aged 20–57 yr) were asked to grasp, lift, and hold stationary, a 250 g object for 20 s. Next, the subjects were asked to perform vertical oscillatory movements over a distance of 20 cm at a rate of 1.0 Hz for 30 s. Eleven trials were performed with intact sensation, and 11 trials after a local ring-block anesthesia of the index and thumb with bupivacain (5 mg/ml). During static holding, loss of cutaneous sensation produced a significant increase in the safety margin. However, the grip force declined significantly over the 20-s static hold period. During oscillatory arm movements, grip and load forces were continuously modulated together in a predictive manner as suggested by Flanagan and Wing. Again, the grip force declined over the 30-s movement, and 7/10 subjects dropped the object at least once. With intact sensation, the object was never dropped; but with the fingers anesthetized, it was dropped on 36% of the trials, and a significant slip occurred on a further 12%. The mean correlation between the grip and load forces for all subjects deteriorated from 0.71 with intact sensation to 0.48 after digital anesthesia. However, a cross-correlation calculated between the grip and load forces indicated that the phase lag was approximately zero both with and without digital anesthesia. Taken together, the data from the present study suggest that cutaneous afferents are required for setting and maintaining the background level of the grip force in addition to their phasic slip-detection function and their role in adapting the grip force/load force ratio to the friction on initial contact with an object. Finally, at a more theoretical level, they correct and maintain an internal model of the physical properties of hand-held objects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.00249.2002

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 330

Metadata

Authors
Augurelle, A.-S., Smith, A. M., Lejeune, T., & Thonnard, J.-L.
Venue
Journal of Neurophysiology
Published
2003-02-01
Volume
89
Issue
2
Pages
665-671
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2015432625
Cited by
330
References
24
FWCI
3.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Importance of Cutaneous Feedback in Maintaining a Secure Grip During Manipulation of Hand-Held Objects. https://app.cochat.ai/papers/10.1152/jn.00249.2002
The paper
Augurelle, A.-S., Smith, A. M., Lejeune, T., & Thonnard, J.-L. (2003). Importance of Cutaneous Feedback in Maintaining a Secure Grip During Manipulation of Hand-Held Objects. Journal of Neurophysiology. https://doi.org/10.1152/jn.00249.2002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.