The fetal mandible: a 2D and 3D sonographic approach to the diagnosis of retrognathia and micrognathia
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Objective: To define parameters that enable the objective diagnosis of anomalies of the position and/or size of the fetal mandible in utero. Design: Fetuses at 18–28 gestational weeks were examined by two‐ and three‐dimensional ultrasound. The study included normal fetuses and fetuses with syndromes associated with known mandible pathology: Pierre Robin sequence or complex (n = 8); hemifacial microsomia (Treacher–Collins syndrome, n = 3); postaxial acrofacial dysostosis (n = 1). Fetuses with Down syndrome (n = 8) and cleft lip and palate without Pierre Robin sequence or complex (n = 18) were also studied. Retrognathia was assessed through the measurement of the inferior facial angle, defined on a mid‐sagittal view, by the crossing of: 1) the line orthogonal to the vertical part of the forehead at the level of the synostosis of the nasal bones (reference line); 2) the line joining the tip of the mentum and the anterior border of the more protruding lip (profile line). Micrognathia was assessed through the calculation of the mandible width/maxilla width ratio on axial views obtained at the alveolar level. Mandible and maxilla widths were measured 10 mm posteriorly to the anterior osteous border. Results: In normal fetuses, the inferior facial angle was constant over the time span studied. The mean (standard deviation) value of the inferior facial angle was 65.5 (8.13)°. Consequently, an inferior facial angle value below 49.2° (mean—2 standard deviations) defined retrognathism. All the fetuses with syndromes associated with mandible pathology had inferior facial angle values below the cut‐off value. Using 49.2° or the rounded‐up value of 50° as a cut‐off point, the inferior facial angle had a sensitivity of 1.0, a specificity of 0.989, a positive predictive value of 0.750 and a negative predictive value of 1.0 to predict retrognathia. In normal fetuses, the mandible width/maxilla width ratio was constant over the time interval studied. The mean (standard deviation) value was 1.017 (0.116). Consequently, a mandible width/maxilla width ratio <0.785 defined micrognathism. Mandible width/maxilla width ratio values were below this cut‐off point in eight and in the normal range in four fetuses with syndromes associated with mandible pathology. Conclusions: Retrognathia and micrognathia are conditions that can be separately assessed. The use of inferior facial angle and mandible width/maxilla width ratio should help sonographic recognition and characterization of fetal retrognathic and micrognathic mandibles in utero. Copyright © 2002 ISUOG
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith's recognizable patterns of human malformation
Jones, K. L., Jones, M. C., & Campo, M. D. (1997) · Cited by 1,916
The profile line as an aid in critically evaluating facial esthetics
Merrifield, L. L. (1966) · American Journal of Orthodontics · doi:10.1016/0002-9416(66)90250-8 · Cited by 403
Objective diagnosis of micrognathia in the fetus: the jaw index
Paladini, D., Morra, T., Teodoro, A., Lamberti, A., Tremolaterra, F., & Martinelli, P. (1999) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00414-1 · Cited by 135
Fetal Facial Defects: Associated Malformations and Chromosomal Abnormalities
Nicolaides, K. H., Salvesen, D. R., Snijders, R. J. M., & Gosden, C. M. (2009) · Fetal Diagnosis and Therapy · doi:10.1159/000263740 · Cited by 127
Fetal micrognathia: associated anomalies and outcome.
Bromley, B., & Benacerraf, B. R. (1994) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1994.13.7.529 · Cited by 96
Digilio, M. C., Marino, B., Ammirati, A., Borzaga, U., Giannotti, A., & Dallapiccola, B. (1999) · American Journal of Medical Genetics · doi:10.1002/(sici)1096-8628(19990604)84:4<311::aid-ajmg1>3.0.co;2-9 · Cited by 91
Measurement of the fetal mandible—feasibility and construction of a centile chart
Chitty, L. S., Campbell, S. C., & Altman, D. G. (1993) · Prenatal Diagnosis · doi:10.1002/pd.1970130809 · Cited by 78
The facial profile in the diagnosis of fetal abnormalities
TURNER, G. M., & Twining, P. (1993) · Clinical Radiology · doi:10.1016/s0009-9260(05)81058-x · Cited by 73
The fetal mandible measurement: an objective determination of fetal jaw size
Otto, C., & Platt, L. D. (1991) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1991.01010012.x · Cited by 69
The prenatal diagnosis of robin anomalad
Pilu, G., Romero, R. J., Reece, E. A., Jeanty, P., & Hobbins, J. C. (1986) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(86)90618-6 · Cited by 51
Sonographic Measurement of the Fetal Mandible: Standards for Normal Pregnancy
Watson, W. J., & Katz, V. (2008) · American Journal of Perinatology · doi:10.1055/s-2007-994725 · Cited by 42
Cited by
Robin Sequence: From Diagnosis to Development of an Effective Management Plan
Evans, K. N., Sie, K. C., Hopper, R. A., Glass, R. P., Hing, A. V., & Cunningham, M. L. (2011) · Pediatrics · doi:10.1542/peds.2010-2615 · Cited by 311
A pictorial guide for the second trimester ultrasound
Bethune, M., Alibrahim, E., Davies, B., & Yong, E. (2013) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/j.2205-0140.2013.tb00106.x · Cited by 55
Sepulveda, W., Wong, A. E., Viñals, F., Andreeva, E., Adzehova, N., & Martinez‐Ten, P. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10121 · Cited by 53
Metadata
- Authors
- Rotten, D., Levaillant, J. M., Martinez, H., Le pointe, H. D., & Vicaut, É.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2002-02
- Volume
- 19
- Issue
- 2
- Pages
- 122-130
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2004684836
- Cited by
- 219
- References
- 11
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.