The importance of locally derived reference ranges and standardized calculation of dilute Russell's viper venom time results in screening for lupus anticoagulant
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Three commercial dilute Russell's viper venom time (DRVVT) kits were evaluated at four UK centres experienced at performing lupus anticoagulant (LA) tests. Each centre established a normal reference range for the DRVVT ratio calculated against local pooled normal plasma from 20 healthy normal subjects. Plasma from LA-positive patients and LA-negative thrombophilia patients was also tested. DRVVT ratios and the degree of correction were assessed in a variety of ways to reflect not only the UK national Guidelines, but also the manufacturers' recommendations. The reference range data showed a normal distribution in each case, but considerable variation in the mean and SD between the centres and reagents, with the mean +2SD value ranging from 1.06 to 1.19. The use of an arbitrary DRVVT ratio of < 1.1 as the cut-off value for normality, which is applied in many laboratories, is therefore inappropriate. Although no single kit had a clear overall advantage in terms of sensitivity and specificity, the way in which the screen and confirmation data were analysed had a major impact on the interpretation of the results. A data analysis method employing a mean plus two standard deviations (SDs) cut-off for normality, and judgement regarding confirmation of LA based on a percentage correction of DRVVT ratio, was the simplest and most consistent, with overall sensitivity and specificity values of 81% and 94%, respectively, for uncomplicated LA-positive and LA-negative thrombophilia samples. We conclude that the 1991 BSCH Guidelines are in need of revision, each laboratory should establish its own normal reference range for the DRVVT ratio and a common method should be used for calculating the degree of correction with confirmation reagents, so that LA results can be correctly interpreted between laboratories. Standardizing DRVVT interpretation in this way should improve the consistency of LA detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brandt, J. T., Triplett, D. A., Alving, B., & Scharrer, I. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649901 · Cited by 993
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Self-citation
Cited by
MIYAKIS, S., LOCKSHIN, M. D., ATSUMI, T., BRANCH, D. W., BREY, R. L., CERVERA, R., DERKSEN, R. H. W. M., DE GROOT, P. G., KOIKE, T., MERONI, P. L., et al. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01753.x · Cited by 7,203
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Self-citationHow we diagnose the antiphospholipid syndrome
Giannakopoulos, B., Passam, F., Ioannou, Y., & Krilis, S. A. (2009) · Blood · doi:10.1182/blood-2007-12-129627 · Cited by 189
Recent Guidelines and Recommendations for Laboratory Detection of Lupus Anticoagulants
Moore, G. (2014) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1364185 · Cited by 149
Laboratory Testing for Lupus Anticoagulants: A Review of Issues Affecting Results
Tripodi, A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.089524 · Cited by 81
Metadata
- Authors
- Gardiner, C., Mackie, I. J., Malia, R. G., Jones, D. W., Winter, M., Leeming, D., Taberner, D. A., Machin, S. J., & Greaves, M.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 2000-12
- Volume
- 111
- Issue
- 4
- Pages
- 1230-1235
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W2046433232
- Cited by
- 55
- References
- 2
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The importance of locally derived reference ranges and standardized calculation of dilute Russell's viper venom time results in screening for lupus anticoagulant. https://app.cochat.ai/papers/10.1046/j.1365-2141.2000.02466.x
- The paper
- Gardiner, C., Mackie, I. J., Malia, R. G., Jones, D. W., Winter, M., Leeming, D., Taberner, D. A., Machin, S. J., & Greaves, M. (2000). The importance of locally derived reference ranges and standardized calculation of dilute Russell's viper venom time results in screening for lupus anticoagulant. British Journal of Haematology. https://doi.org/10.1046/j.1365-2141.2000.02466.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.