Prognostic value of positron emission tomography in the evaluation of post‐treatment residual mass in patients with Hodgkin's disease and non‐Hodgkin's lymphoma
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The prognostic value of 18 F‐fluorodeoxyglucose (FDG) positron emission tomography (PET) in the assessment of post‐treatment residual masses in patients with Hodgkin's disease (HD) or non‐Hodgkin's lymphomas (NHL) was evaluated. We prospectively studied 58 patients with HD (n = 43) or NHL (n = 15) who had post‐therapeutic complete remission with residual masses (CRu) indicated by computerized tomography. Analysis of 62 residual locations by FDG‐PET was performed separately for HD and NHL. Patients with a PET‐positive residual mass [standardized uptake value (SUV) > 3] had a recurrence rate of 62·5% (5/8 patients), whereas patients with PET‐negative residual mass (SUV ≤ 3·0) showed a recurrence rate of 4% (2/50 patients, P = 0·004). A positive FDG‐PET study correlated with a significantly poorer progression‐free survival (P < 0·00001). No recurrence occurred in any of the 39 HD patients with a negative PET scan (negative predictive value, 100%). Four out of four NHL patients with a positive PET study relapsed (positive predictive value, 100%). In conclusion, FDG‐PET is a suitable non‐invasive method with a high degree of accuracy in the prediction of early recurrence in lymphoma patients with CRu.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warburg, O. (1956) · Science · doi:10.1126/science.123.3191.309 · Cited by 13,425
Report of an International Workshop to Standardize Response Criteria for Non-Hodgkin's Lymphomas
Cheson, B. D., Horning, S. J., Coiffier, B., Shipp, M. A., Fisher, R. I., Connors, J. M., Lister, T. A., Vose, J., Grillo-López, A., Hagenbeek, A., et al. (1999) · Journal of Clinical Oncology · doi:10.1200/jco.1999.17.4.1244 · Cited by 3,486
Harris, N. L., Jaffe, E. S., Diebold, J., Flandrin, G., Muller-Hermelink, H. K., Vardiman, J., Lister, T. A., & Bloomfield, C. D. (1999) · Journal of Clinical Oncology · doi:10.1200/jco.1999.17.12.3835 · Cited by 3,267
Lister, T. A., Crowther, D., Sutcliffe, S. B., Glatstein, E., Canellos, G. P., Young, R. C., Rosenberg, S. A., Coltman, C. A., & Tubiana, M. (1989) · Journal of Clinical Oncology · doi:10.1200/jco.1989.7.11.1630 · Cited by 1,639
(1992) · PubMed Central · doi:10.2967/jnumed.120.251744a · Cited by 1,172
The applications of PET in clinical oncology.
Strauss, L. G., & Conti, P. S. (1991) · PubMed · Cited by 844
Flamen, P., Lerut, A., Van Cutsem, E., De Wever, W., Peeters, M., Stroobants, S., Dupont, P., Bormans, G., Hiele, M., De Leyn, P., et al. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.18.3202 · Cited by 571
Jerusalem, G., Beguin, Y., Fassotte, M. F., Najjar, F., Paulus, P., Rigo, P., & Fillet, G. (1999) · Blood · doi:10.1182/blood.v94.2.429 · Cited by 565
Gallagher, B. M., Fowler, J. S., Gutterson, N. I., MacGregor, R. R., Wan, C.-N., & Wolf, A. P. (1978) · PubMed · Cited by 557
Avril, N., Rosé, C. A., Schelling, M., Dose, J., Kuhn, W., Bense, S., Weber, W., Ziegler, S., Graeff, H., & Schwaiger, M. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.20.3495 · Cited by 557
Cited by
Revised Response Criteria for Malignant Lymphoma
Cheson, B. D., Pfistner, B., Juweid, M. E., Gascoyne, R. D., Specht, L., Horning, S. J., Coiffier, B., Fisher, R. I., Hagenbeek, A., Zucca, E., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.2403 · Cited by 4,426
Juweid, M. E., Stroobants, S., Hoekstra, O. S., Mottaghy, F. M., Dietlein, M., Guermazi, A., Wiseman, G. A., Kostakoglu, L., Scheidhauer, K., Buck, A., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.08.2305 · Cited by 1,335
Self-citationProgress and Promise of FDG-PET Imaging for Cancer Patient Management and Oncologic Drug Development
Kelloff, G. J., Hoffman, J. M., Johnson, B., Scher, H. I., Siegel, B. A., Cheng, E. Y., Cheson, B. D., O'Shaughnessy, J., Guyton, K. Z., Mankoff, D. A., et al. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2626 · Cited by 671
Utility of FDG-PET scanning in lymphoma by WHO classification
Elstrom, R., Guan, L., Baker, G., Nakhoda, K., Vergilio, J.-A., Zhuang, H., Pitsilos, S., Bagg, A., Downs, L., Mehrotra, A., et al. (2003) · Blood · doi:10.1182/blood-2002-09-2778 · Cited by 437
Prognostic value of interim FDG-PET after two or three cycles of chemotherapy in Hodgkin lymphoma
Hutchings, M., Mikhaeel, N. G., Fields, P. A., Nunan, T., & Timothy, A. R. (2005) · Annals of Oncology · doi:10.1093/annonc/mdi200 · Cited by 327
Positron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
Role of Functional Imaging in the Management of Lymphoma
Cheson, B. D. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2010.32.5225 · Cited by 280
FDG-PET/CT in re-staging of patients with lymphoma
Freudenberg, L. S., Antoch, G., Sch�tt, P., Beyer, T., Jentzen, W., M�ller, S. P., G�rges, R., Nowrousian, M. R., Bockisch, A., & Debatin, J. F. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1375-y · Cited by 246
PET/CT for Therapy Response Assessment in Lymphoma
Hutchings, M., & Barrington, S. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057190 · Cited by 220
“(22) 2005 2 or 3 85 HL 13 8 (62) 72 4 (6) 6–125 Hutchings et al.”
Overview of the clinical effectiveness of positron emission tomography imaging in selected cancers
Facey, K., Bradbury, I., Laking, G., & Payne, E. (2007) · Health Technology Assessment · doi:10.3310/hta11440 · Cited by 219
Molecular Imaging of Proliferation in Malignant Lymphoma
Buck, A. K., Bommer, M., Stilgenbauer, S., Juweid, M., Glatting, G., Schirrmeister, H., Mattfeldt, T., Tepsic, D., Bunjes, D., Mottaghy, F. M., et al. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-1955 · Cited by 185
Naumann, R., Beuthien-Baumann, B., Reiß, A., Schulze, J., Hänel, A., Bredow, J., Kühnel, G., Kropp, J., Hänel, M., Laniado, M., et al. (2004) · British Journal of Cancer · doi:10.1038/sj.bjc.6601561 · Cited by 171
“The published sensitivity and specifity emphasises the value of 18FFDG-PET in the staging of lymphoma and explains the increasing acceptance of this method (Jerusalem et al, 2001; Naumann et al, 2001; Spaepen et al, 2001; Kostakoglu et al, 2002; Guay et al, 2003).”
MethodSelf-citationMonitoring response to treatment in patients utilizing PET
Avril, N. E., & Weber, W. A. (2005) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2004.09.006 · Cited by 171
“Naumann et al, 2001 [76] 2001 58 88 68 NA NA”
InfluentialKostakoglu, L., Goldsmith, S. J., Leonard, J. P., Christos, P., Furman, R. R., Atasever, T., Chandramouly, A., Verma, S., Kothari, P., & Coleman, M. (2006) · Cancer · doi:10.1002/cncr.22276 · Cited by 168
“0 were 100% and 93%, respectively.(17) These cutoff values, however, may be different depending on the patient population and therapy modality.”
BackgroundMethodHigashi, T., Saga, T., Nakamoto, Y., Ishimori, T., Fujimoto, K., Doi, R., Imamura, M., & Konishi, J. (2003) · Annals of Nuclear Medicine · doi:10.1007/bf02988521 · Cited by 165
Ngeow, J. Y. Y., Quek, R. H. H., Ng, D. C. E., Hee, S. W., Tao, M., Lim, L. C., Tan, Y. H., & Lim, S. T. (2009) · Annals of Oncology · doi:10.1093/annonc/mdp030 · Cited by 164
Metadata
- Authors
- Naumann, R., Vaic, A., Beuthien‐Baumann, B., Bredow, J., Kropp, J., Kittner, T., Franke, W., & Ehninger, G.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 2001-12
- Volume
- 115
- Issue
- 4
- Pages
- 793-800
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W2053487101
- Cited by
- 212
- References
- 29
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.