Food allergy–getting more out of your skin prick tests
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Skin prick testing has been used for over a 100 years [1] and is of fundamental importance in the practice of clinical allergy. While it is an important tool in the context of a clinical history, there are limits to its value. We are therefore often unable to establish definitive diagnoses of food allergy without resorting to food challenges. In this issue of the Journal, Sporik et al. [2] present a case series of 467 children, aged 1 month to 16 years, evaluated for suspected food allergy in a tertiary paediatric allergy clinic. They correlate skin prick weal sizes with the results of open food challenges to cows milk, egg or peanut. Their data demonstrate that if the traditional 3 mm weal is used as the lower limit for defining allergy, there are many false-positive and -negative results (Fig. 1a). This creates a large immunological grey area where we cannot make a definitive diagnoses on the basis of the test result. Their paper demonstrates how this problem can be overcome by increasing the cut-off value, thereby reducing the immunological grey area (Fig. 1b). They identify skin weal diameters at and above which negative reactions do not occur on food challenge: cow's milk, 8 mm; egg, 7 mm; and peanut, 8 mm. The need for a corroborative food challenge to make the diagnosis could have been avoided in 33%, 56% and 68%, respectively, of the children in this population. Such an approach has great clinical significance, considerably reducing the need for costly and time-consuming food challenges. . The value of using different cut-off levels to diagnose peanut allergy with skin prick testing. Data taken from Sporik's population [2]. (a) The low cut-off value of 3 mm for skin prick testing, that is traditionally used, is associated with a significant number of false negative and false positive results. Whether the wheal diameter is more or less than 3 mm, we cannot use the result to definitively rule in or rule out the diagnosis of peanut allergy. This creates a large immunological grey area where the test results are of limited value as they cannot be used diagnostically. (b) With a high cut-off value of 8 mm, we are able to establish a definitive diagnosis of peanut allergy in 43% of Sporik's population [2]. This considerably reduces the size of the immunological grey area and the need for food challenges. (●) Food-allergic subjects; (○) normal subjects; background grey colour represents the immunological grey area. The concept of a cut-off value, above which a test has a very high positive predictive value for food allergy, is not entirely new. Specific IgE values, generated by the Pharmacia Cap system, have been correlated with the results of double-blinded food challenges [3]. Specific IgE results giving positive predictive values of at least 95% were: egg, 6 kUA/L; milk, 32 kUA/L; peanut, 15 kUA/L; and fish, 20 kUA/L. Skin prick testing has considerable advantages in terms of cost and the time taken for a result to be available. How applicable are these skin prick cut-off values [2] to other patients in different clinical settings? Cutaneous reactivity is known to vary with age. The histamine-induced wheal diameter increases by 125% from 4 days to 24 months [4] with further 50% increase over the childhood and teenage years [5]. Similar changes with age occur in response to codeine, a mast cell degranulator [4]. There is also data to suggest that time of day [6], season [7] and patient's sex [8] affect cutaneous reactivity. Together, these data suggest that if skin prick testing is to be standardized, results may need to be interpreted in terms of factors such as the subject's age and sex as well as the timing of the test. To achieve optimal specificity, different cut off values are likely to be required for different subpopulations of children. For a test to be widely applicable, it must be performed using a standardized technique. The single headed lancet, used in this study [2], has a lower intra-and interoperator variability than other methods, such as the bifurcated or multiheaded lancet systems [9, 10]. In addition to the technique, the site chosen is critical with a 20% variation in weal size, with histamine or allergen, depending on which part of the body is used for skin testing [9]. Whilst standardization of skin prick testing in terms of the population characteristics and technique employed is important, standardization of the allergen content of the reagent is the single most important determinant of outcome. Despite the efforts of international committees [11], there is a lack of reagent standardization for food allergens. Commercial skin prick tests for peanut have been found to have different RAST inhibition curves, suggesting that they have different IgE-binding determinants, and concentrations of Ara h 1 and Ara h 2 that vary by a 100-fold [12]. Similar results have been seen with other food extract preparations [13]. For each food, there is an optimal allergen concentration for skin pri
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1975) · New England Journal of Medicine · doi:10.1056/nejm197507312930513 · Cited by 1,017
Position Paper: Allergen standardization and skin tests
Dreborg, S., & Frew, A. (1993) · Allergy · doi:10.1111/j.1398-9995.1993.tb04756.x · Cited by 753
Cited by
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723
Basophil activation test discriminates between allergy and tolerance in peanut-sensitized children
Santos, A. F., Douiri, A., Bécares, N., Wu, S.-Y., Stephens, A., Radulovic, S., Chan, S. M. H., Fox, A. T., Du Toit, G., Turcanu, V., et al. (2014) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2014.04.039 · Cited by 314
Self-citationDiagnosing peanut allergy with skin prick and specific IgE testing
Roberts, G., Lack, G., & Pa, T. A. L. S. O. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.02.038 · Cited by 293
Self-citationIncreasing the accuracy of peanut allergy diagnosis by using Ara h 2
Dang, T. D., Tang, M., Choo, S., Licciardi, P. V., Koplin, J. J., Martin, P. E., Tan, T., Gurrin, L. C., Ponsonby, A.-L., Tey, D., et al. (2012) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2012.01.056 · Cited by 243
Peters, R. L., Allen, K. J., Dharmage, S. C., Tang, M. L. K., Koplin, J. J., Ponsonby, A.-L., Lowe, A. J., Hill, D., & Gurrin, L. C. (2013) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2013.05.038 · Cited by 224
Clark, A. T., & Ewan, P. W. (2003) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2745.2003.01624.x · Cited by 185
Improving Diagnostic Accuracy in Food Allergy
Foong, R.-X., Dantzer, J. A., Wood, R. A., & Santos, A. F. (2021) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2020.09.037 · Cited by 135
A new framework for the interpretation of IgE sensitization tests
Roberts, G., Ollert, M., Aalberse, R., Austin, M., Custovic, A., DunnGalvin, A., Eigenmann, P. A., Fassio, F., Grattan, C., Hellings, P., et al. (2016) · Allergy · doi:10.1111/all.12939 · Cited by 98
“The introduction of 95% positive predictive values (29) has helped clinicians to provide more clinically relevant recommendations from the test results.”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Roberts, G., & Lack, G.
- Venue
- Clinical & Experimental Allergy
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 30
- Issue
- 11
- Pages
- 1495-1498
- ISSN
- 0954-7894 (ISSN-L)
- 1365-2222
- OpenAlex
- W2038662037
- Cited by
- 54
- References
- 2
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.