Three different chromogenic methods do not give equivalent anti-Xa levels for patients on therapeutic low molecular weight heparin (dalteparin) or unfractionated heparin: M.J. Kovas et al.
The DOI matches its Crossref record.
Abstract
In this study we compare three chromogenic methods (IL-Heparin, Stachrom Heparin and Heparin Sigma) on two different instruments (ACL300+ and AMAX CS190) for patients on dalteparin (n = 41), a low molecular weight heparin or unfractionated heparin (n = 50). For dalteparin the mean anti-Xa levels for IL-Heparin, Stachrom Heparin and Heparin Sigma were 0.27, 0.30 and 0.21 U/ml, respectively, while for heparin they were 0.52, 0.55 and 0.41 U/ml, respectively. To test for instrument specific effects, IL-Heparin and Stachrom Heparin were repeated on both instruments on 42 patients receiving unfractionated heparin. For IL-Heparin the mean anti-Xa levels on the AMAX CS190 and ACL300+ were 0.51 and 0.59 U/ml, respectively, while for Stachrom Heparin they were 0.55 and 0.67 anti-Xa U/ml. We conclude that different chromogenic anti-Xa methods do not give equivalent anti-Xa levels for the same samples. Moreover, the differences are clinically significant. This is not explained entirely by instrumentation effects. Recommended therapeutic ranges may need to be method and instrument specific.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
VTE, Thrombophilia, Antithrombotic Therapy, and Pregnancy
Bates, S. M., Greer, I. A., Middeldorp, S., Veenstra, D. L., Prabulos, A.-M., & Vandvik, P. O. (2012) · Chest · doi:10.1378/chest.11-2300 · Cited by 1,525
Bates, S. M., Rajasekhar, A., Middeldorp, S., McLintock, C., Rodger, M. A., James, A. H., Vazquez, S. R., Greer, I. A., Riva, J. J., Bhatt, M., et al. (2018) · Blood Advances · doi:10.1182/bloodadvances.2018024802 · Cited by 625
Guidance for the treatment and prevention of obstetric-associated venous thromboembolism
Bates, S. M., Middeldorp, S., Rodger, M., James, A. H., & Greer, I. (2016) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-015-1309-0 · Cited by 441
Nutescu, E. A., Spinier, S. A., Wittkowsky, A., & Dager, W. E. (2009) · Annals of Pharmacotherapy · doi:10.1345/aph.1l194 · Cited by 289
Guidelines on the use and monitoring of heparin
Baglin, T., Barrowcliffe, T. W., Cohen, A., Greaves, M., & the British Committee for Standards in Haematology (2006) · British Journal of Haematology · doi:10.1111/j.1365-2141.2005.05953.x · Cited by 262
Metadata
- Authors
- Kovacs, M. J., Keeney, M., Mackinnon, K., & Boyle, E.
- Venue
- Clinical & Laboratory Haematology
- Publisher
- Wiley
- Published
- 1999-02
- Volume
- 21
- Issue
- 1
- Pages
- 55-60
- ISSN
- 0141-9854 (ISSN-L)
- OpenAlex
- W1981859573
- Cited by
- 76
- References
- 0
- FWCI
- 0.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three different chromogenic methods do not give equivalent anti-Xa levels for patients on therapeutic low molecular weight heparin (dalteparin) or unfractionated heparin: M.J. Kovas et al. https://app.cochat.ai/papers/10.1046/j.1365-2257.1999.00183.x
- The paper
- Kovacs, M. J., Keeney, M., Mackinnon, K., & Boyle, E. (1999). Three different chromogenic methods do not give equivalent anti-Xa levels for patients on therapeutic low molecular weight heparin (dalteparin) or unfractionated heparin: M.J. Kovas et al. Clinical & Laboratory Haematology. https://doi.org/10.1046/j.1365-2257.1999.00183.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.