CoChat

Evaluation of endothelium‐dependent vasodilation in the human peripheral circulation

Lind, Lars, Hall, Jan, Larsson, Anders, Annuk, Margus, Fellström, Bengt, Lithell, Hans · 2000 · Clinical Physiology
Cited by 99

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Flow‐mediated vasodilation (FMD) in the brachial artery measured by ultrasound, and the increase in forearm blood flow (FBF) induced by local infusion of a muscarinic‐receptor agonist have both frequently been used to evaluate endothelium‐dependent vasodilation (EDV) in the human forearm. The present study intended to evaluate the relationship between these techniques and to investigate if vasodilation induced by the muscarinic receptor‐agonist methacholine (MCh) was owing to production of nitric oxide (NO). FMD during hyperaemia was assessed by ultrasound and FBF was measured by venous occlusion plethysmography during local infusion of MCh or L‐arginine in the human forearm. Both these methods were applied in 26 individuals. In another 12 individuals forearm arterial and venous plasma concentrations of nitrate/nitrite (NOx) were measured together with FBF before and during local MCh infusion.While the change in brachial artery diameter induced by sublingually given nitroglycerine and the vasodilatory response to sodium nitroprusside (SNP) given locally in the forearm were significantly correlated (r=0·70, P<0·01), FMD showed no relationship with the vasodilation evoked by MCh (r=–0·03) or L‐arginine (r=0·04). The five‐fold increase in FBF during MCh infusion was associated with a significant increase in venous plasma NOx concentrations (P<0·05) and a more than 11‐fold increase in forearm NOx‐release (P<0·01). Thus, a significant relationship between the two methods regarding the evaluation of endothelium‐independent vasodilation evoked by NO‐donors was found, but no relationship was found between the two methods regarding the evaluation of endothelium‐dependent vasodilation. Furthermore, vasodilation induced by MCh in the forearm seems to be induced by NO‐release.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2281.2000.00281.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 99

Metadata

Authors
Lind, L., Hall, J., Larsson, A., Annuk, M., Fellström, B., & Lithell, H.
Venue
Clinical Physiology
Publisher
Wiley
Published
2000-11-14
Volume
20
Issue
6
Pages
440-448
ISSN
  • 0144-5979 (ISSN-L)
  • 1365-2281
OpenAlex
W2097090662
Cited by
99
References
2
FWCI
6.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of endothelium‐dependent vasodilation in the human peripheral circulation. https://app.cochat.ai/papers/10.1046/j.1365-2281.2000.00281.x
The paper
Lind, L., Hall, J., Larsson, A., Annuk, M., Fellström, B., & Lithell, H. (2000). Evaluation of endothelium‐dependent vasodilation in the human peripheral circulation. Clinical Physiology. https://doi.org/10.1046/j.1365-2281.2000.00281.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.