CoChat

Coronary flow reserve: measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography

Saraste, M., Koskenvuo, J. W., Knuuti, J., Toikka, J. O., Laine, H., Niemi, P., Sakuma, H., Hartiala, J. J. · 2001 · Clinical Physiology
Cited by 179

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Detection of early vascular changes indicated by lowered coronary flow reserve (CFR) would allow early treatment and prevention of atherosclerosis. The purpose of this study was to test whether it is possible to reproducibly measure CFR with transthoracic Doppler echocardiography (TTE) in healthy volunteers. We measured CFR using dipyridamole infusion in ten healthy male volunteers with two methods: TTE and positron emission tomography (PET) with oxygen‐15‐labelled water (group A). However, CFR was assessed twice with TTE in eight healthy male volunteers (group B) to study the reproducibility of this method. We compared CFRs obtained using TTE flow measurements in the left anterior descending coronary artery (LAD) and PET flow measurements in the corresponding myocardial area. Coronary flow in LAD could be measured in all subjects using TTE. By TTE, an average CFR based on peak diastolic flow velocity (PDV) was 2·72 ± 1·16, mean diastolic flow velocity (MDV) 2·56 ± 1·06 and velocity time integral (VTI) 1·87 ± 0·49. The results were reproducible in two repeated TTE studies (coefficient of variation in MDV 6·1 ± 4·3%,n=8). By PET, CFR was 2·52 ± 0·84. CFR assessed by TTE correlated closely with that measured by PET (MDV r=0·942,P<0·001; PDV r=0·912,P<0·002 and VTI r=0·888,P<0·006) and intraclass correlation was 0·929 (MDV) and tolerance limits for differences of CFRs was −0·78 to 0·72. We show that CFR measured by TTE has an excellent correlation with CFR measured by PET. We also found that TTE measurements of CFR were highly reproducible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2281.2001.00296.x

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 179

Metadata

Authors
Saraste, M., Koskenvuo, J. W., Knuuti, J., Toikka, J. O., Laine, H., Niemi, P., Sakuma, H., & Hartiala, J. J.
Venue
Clinical Physiology
Publisher
Wiley
Published
2001-01
Volume
21
Issue
1
Pages
114-122
ISSN
  • 0144-5979 (ISSN-L)
  • 1365-2281
OpenAlex
W1990402962
Cited by
179
References
22
FWCI
5.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coronary flow reserve: measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography. https://app.cochat.ai/papers/10.1046/j.1365-2281.2001.00296.x
The paper
Saraste, M., Koskenvuo, J. W., Knuuti, J., Toikka, J. O., Laine, H., Niemi, P., Sakuma, H., & Hartiala, J. J. (2001). Coronary flow reserve: measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography. Clinical Physiology. https://doi.org/10.1046/j.1365-2281.2001.00296.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.