CoChat

Occurrence of sialic acids in healthy humans and different disorders

Sillanaukee, Pönniö, Jääskeläinen · 1999 · European Journal of Clinical Investigation
Cited by 252

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Sialic acid (SA), N‐acetylated derivatives of neuraminic acid, play a central role in the biomedical functioning of humans. The normal range of total sialic acid (TSA) level in serum/plasma is 1.58–2.22 mmol L−1, the free form of SA only constituting 0.5–3 μmol L−1 and the lipid‐associated (LSA) forms 10–50 μmol L−1. Notably, considerably higher amounts of free SA are found in urine than in serum/plasma (approximately 50% of the total SA). In inherited SA storage diseases such as Salla's disease, SA levels are elevated many times over, and their determination during clinical investigation is well established. Furthermore, a number of reports describe elevated SA levels in various other diseases, tentatively suggesting broader clinical utility for SA markers. Increased SA concentrations have been reported during inflammatory processes, probably resulting from increased levels of richly sialylated acute‐phase glycoproteins. A connection between increased SA levels and elevated stroke and cardiovascular mortality risk has also been reported. In addition, SA levels are slightly increased in cancer, positively correlating with the degree of metastasis, as well as in alcohol abuse, diabetes, chronic renal failure and chronic glomerulonephritis. Several different mechanisms are assumed to underlie the elevated SA concentrations in these disorders. The apparent non‐specificity of SA to a given disease limits the potential clinical usefulness of SA determination. In addition, some non‐pathological factors, such as aging, pregnancy and smoking, may cause changes in SA concentrations. The absolute increases in SA levels are also rather small (save those in inherited SA storage disorders); this further limits the clinical potential of SA as a marker. Tentatively, SA markers might serve as adjuncts, when combined with other markers, in disease screening, disease progression follow‐up, and in the monitoring of treatment response. To become clinically useful, however, the existing SA determination assays need to be considerably refined to reduce interferences, to be specific for certain SA forms, and to be more easy to use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2362.1999.00485.x

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 252

Metadata

Authors
Sillanaukee, Pönniö, & Jääskeläinen
Venue
European Journal of Clinical Investigation
Publisher
Wiley
Published
1999-05
Volume
29
Issue
5
Pages
413-425
ISSN
  • 0014-2972 (ISSN-L)
  • 1365-2362
OpenAlex
W2158023865
Cited by
252
References
39
FWCI
1.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Occurrence of sialic acids in healthy humans and different disorders. https://app.cochat.ai/papers/10.1046/j.1365-2362.1999.00485.x
The paper
Sillanaukee, Pönniö, & Jääskeläinen. (1999). Occurrence of sialic acids in healthy humans and different disorders. European Journal of Clinical Investigation. https://doi.org/10.1046/j.1365-2362.1999.00485.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.