Estimating core temperature in infants and children after cardiac surgery: a comparison of six methods
The DOI matches its Crossref record.
Abstract
Background. Monitoring temperature in critically ill children is an important component of care, yet the accuracy of methods is often questioned. Temperature measured in the pulmonary artery is considered the ‘gold standard’, but this route is unsuitable for the majority of patients. An accurate, reliable and less invasive method is, however, yet to be established in paediatric intensive care work. Aim. To determine which site most closely reflects core temperature in babies and children following cardiac surgery, by comparing pulmonary artery temperature to the temperature measured at rectal, bladder, nasopharyngeal, axillary and tympanic sites. Method. A convenience sample of 19 postoperative cardiac patients was studied. Interventions. Temperature was recorded as a continuous measurement from pulmonary artery, rectal, nasopharyngeal and bladder sites. Axillary and tympanic temperatures were recorded at 30 minute intervals for 6 1/2 hours postoperatively. Study limitations. The small sample size of 19 infants and children limits the generalizability of the study. Results. Repeated measures analysis of variance demonstrated no significant difference between pulmonary artery and bladder temperatures, and pulmonary artery and nasopharyngeal temperatures. Intraclass correlation showed that agreement was greatest between pulmonary artery temperature and temperature measured by bladder catheter. There was a significant difference between pulmonary artery temperature and temperature measured at rectal, tympanic and pulmonary artery and axillary sites. Repeated measures analysis showed a significant lag between pulmonary artery and rectal temperature of between 0 and 150 minutes after the 6‐hour measurement period. Conclusions. In this study, bladder temperature was shown to be the best estimate of pulmonary artery temperature, closely followed by the temperature measured by nasopharyngeal probe. The results support the use of bladder or nasopharyngeal catheters to monitor temperature in critically ill children after cardiac surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Greer, R. J., Cohn, L. A., Dodam, J. R., Wagner-Mann, C. C., & Mann, F. A. (2007) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.230.12.1841 · Cited by 101
Temperature measurements with a temporal scanner: systematic review and meta-analysis
Geijer, H., Udumyan, R., Lohse, G., & Nilsagård, Y. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-009509 · Cited by 66
“53 54 Long-term risks are not known, but rectal temperature measurements could together with other painful, stressful and integrity insulting procedures add to psychological suffering for the child.”
Background
Metadata
- Authors
- Maxton, F. J. C., Justin, L., & Gillies, D.
- Venue
- Journal of Advanced Nursing
- Publisher
- Wiley
- Published
- 2004-01
- Volume
- 45
- Issue
- 2
- Pages
- 214-222
- ISSN
- 0309-2402 (ISSN-L)
- 1365-2648
- OpenAlex
- W1972381935
- Cited by
- 50
- References
- 0
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating core temperature in infants and children after cardiac surgery: a comparison of six methods. https://app.cochat.ai/papers/10.1046/j.1365-2648.2003.02883.x
- The paper
- Maxton, F. J. C., Justin, L., & Gillies, D. (2004). Estimating core temperature in infants and children after cardiac surgery: a comparison of six methods. Journal of Advanced Nursing. https://doi.org/10.1046/j.1365-2648.2003.02883.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).