The DOI matches its Crossref record.
Adherence of Listeria monocytogenes strains to stainless steel coupons
Abstract
An assay was developed to measure the number of Listeria monocytogenes cells adhering to stainless steel, and was used to investigate the adherence of 111 strains of the organism, which included representatives with respect to serotype, carriage of plasmids, source and persistence in the food processing environment. Growth and adherence curves of four L. monocytogenes strains over 48 h were obtained. While the growth curves of all four micro-organisms were seen to reach similar levels at stationary phase, there was still substantial variation among the adherence curves. In addition, a scatter-graph of growth vs adherence counts at 24 h showed poor correlation. These factors indicated that interstrain variation in adherence at stationary phase is due to factor(s) intrinsic to each strain of L. monocytogenes. Persistent strains were found to adhere in significantly greater numbers than sporadic strains, and variation was also found among serotypes, with serotype 1/2c showing significantly greater adherence than serotypes 1/2a and 4b; 4b strains were significantly higher than those of 1/2a strains. No significant difference was found between strains according to source or plasmid carriage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bacterial cell attachment, the beginning of a biofilm
Palmer, J., Flint, S., & Brooks, J. (2007) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-007-0234-4 · Cited by 755
Ferreira, V., Wiedmann, M., Teixeira, P., & Stasiewicz, M. J. (2014) · Journal of Food Protection · doi:10.4315/0362-028x.jfp-13-150 · Cited by 745
Listeria monocytogenes Virulence and Pathogenicity, a Food Safety Perspective
Kathariou, S. (2002) · Journal of Food Protection · doi:10.4315/0362-028x-65.11.1811 · Cited by 727
Van Houdt, R., & Michiels, C. W. (2010) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2010.04756.x · Cited by 684
Variation in Biofilm Formation among Strains of Listeriamonocytogenes
Borucki, M. K., Peppin, J. D., White, D., Loge, F., & Call, D. R. (2003) · Applied and Environmental Microbiology · doi:10.1128/aem.69.12.7336-7342.2003 · Cited by 519
Metadata
- Authors
- Norwood, D. E., & Gilmour, A.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-04
- Volume
- 86
- Issue
- 4
- Pages
- 576-582
- ISSN
- 1364-5072 (ISSN-L)
- 1365-2672
- OpenAlex
- W2089329439
- Cited by
- 191
- References
- 0
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adherence of Listeria monocytogenes strains to stainless steel coupons. https://app.cochat.ai/papers/10.1046/j.1365-2672.1999.00694.x
- The paper
- Norwood, D. E., & Gilmour, A. (1999). Adherence of Listeria monocytogenes strains to stainless steel coupons. Journal of Applied Microbiology. https://doi.org/10.1046/j.1365-2672.1999.00694.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.