One explanation for the variability of the bacterial suspension test
The DOI matches its Crossref record.
Abstract
Disinfection kinetic studies of sodium dodecyl sulphate, benzalkonium chloride and sodium hypochlorite against Staphylococcus aureus revealed that when a higher inoculum level of Staph. aureus than normal was used (approximately 1 log higher), the efficacy of disinfection was severely attenuated. Kinetic analysis using the Hom model for experiments carried out on tests using 3 x 108 organisms ml-1 were unable to account for the large increase in disinfection power observed when smaller inoculum levels were used. Since the inoculum was the same in every way except for the numbers used, the large variations in the log reduction/time curves could not be explained by a variation in the resistance of the population to the biocide, as identical log reduction-time curves should have resulted. The level of disinfection achieved for a given concentration of biocide was found to be approximately linearly related to the cell number ml-1 of test solution and not to the log number. The variation observed is believed to occur due to intrinsic self-quenching of the biocide by the microbes during the course of the disinfection test. As the level of free biocide decreases, the rate of reaction decreases, giving the tails of the log reduction/time curves. Such intrinsic self-quenching could explain the large variations known to occur in the legally required disinfection suspension tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent developments in photocatalytic water treatment technology: A review
Chong, M. N., Jin, B., Chow, C. W. K., & Saint, C. (2010) · Water Research · doi:10.1016/j.watres.2010.02.039 · Cited by 5,386
“Johnston et al. (2000) showed that the inoculum size of the bacteria has a large impact on resistance distribution and thus, the errors associated with this term should be given attention during the mechanistic modelling. dCundam dt ¼ k1KundamC hundam undam 1þ KundamC hundam undam þ KdamC hdam…”
BackgroundFriedman, M., Henika, P. R., & Mandrell, R. E. (2002) · Journal of Food Protection · doi:10.4315/0362-028x-65.10.1545 · Cited by 1,127
Buffet-Bataillon, S., Tattevin, P., Bonnaure-Mallet, M., & Jolivet-Gougeon, A. (2012) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2012.01.011 · Cited by 601
Hegstad, K., Langsrud, S., Lunestad, B. T., Scheie, A. A., Sunde, M., & Yazdankhah, S. P. (2010) · Microbial Drug Resistance · doi:10.1089/mdr.2009.0120 · Cited by 396
Microbial inactivation using plasma-activated water obtained by gliding electric discharges
Kamgang-Youbi, G., Herry, J.-M., Meylheuc, T., Brisset, J.-L., Bellon-Fontaine, M.-N., Doubla, A., & Naïtali, M. (2009) · Letters in Applied Microbiology · doi:10.1111/j.1472-765x.2008.02476.x · Cited by 226
“This parameter, which is rarely considered in disinfection, may be influential (Johnston et al. 2000).”
Background
Metadata
- Authors
- Johnston, M. D., Simons, E. A., & Lambert, R. J. W.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-02
- Volume
- 88
- Issue
- 2
- Pages
- 237-242
- ISSN
- 1364-5072 (ISSN-L)
- 1365-2672
- OpenAlex
- W2013763637
- Cited by
- 58
- References
- 0
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One explanation for the variability of the bacterial suspension test. https://app.cochat.ai/papers/10.1046/j.1365-2672.2000.00951.x
- The paper
- Johnston, M. D., Simons, E. A., & Lambert, R. J. W. (2000). One explanation for the variability of the bacterial suspension test. Journal of Applied Microbiology. https://doi.org/10.1046/j.1365-2672.2000.00951.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.