The DOI matches its Crossref record.
Detection and quantification of Escherichia coli O157:H7 in environmental samples by real-time PCR
Abstract
AIMS: To apply the real-time Polymerase chain reaction (PCR) method to detect and quantify Escherichia coli O157:H7 in soil, manure, faeces and dairy waste washwater. METHODS AND RESULTS: Soil samples were spiked with E. coli O157:H7 and subjected to a single enrichment step prior to multiplex PCR. Other environmental samples suspected of harbouring E.coli O157:H7 were also analysed. The sensitivity of the primers was confirmed with DNA from E.coli O157:H7 strain 3081 spiked into soil by multiplex PCR assay. A linear relationship was measured between the fluorescence threshold cycle (C T ) value and colony counts (CFU ml(-1)) in spiked soil and other environmental samples. The detection limit for E.coli O157:H7 in the real-time PCR assay was 3.5 x 10(3) CFU ml(-1) in pure culture and 2.6 x 10(4) CFU g(-1) in the environmental samples. Use of a 16-h enrichment step for spiked samples enabled detection of <10 CFU g(-1) soil. E. coli colony counts as determined by the real-time PCR assay, were in the range of 2.0 x 10(2) to 6.0 x 10(5) CFU PCR (-1) in manure, faeces and waste washwater. CONCLUSIONS: The real-time PCR-based assay enabled sensitive and rapid quantification of E. coli O157:H7 in soil and other environmental samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to quantitatively determine cell counts of E.coli O157:H7 in large numbers of environmental samples, represents considerable advancement in the area of pathogen quantification for risk assessment and transport studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A rapid bioassay for single bacterial cell quantitation using bioconjugated nanoparticles
Zhao, X., Hilliard, L. R., Mechery, S. J., Wang, Y., Bagwe, R. P., Jin, S., & Tan, W. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404806101 · Cited by 569
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Biosensors for rapid detection of bacterial pathogens in water, food and environment
Nnachi, R. C., Sui, N., Ke, B., Luo, Z., Bhalla, N., He, D., & Yang, Z. (2022) · Environment International · doi:10.1016/j.envint.2022.107357 · Cited by 297
Ongeng, D., Geeraerd, A. H., Springael, D., Ryckeboer, J., Muyanja, C., & Mauriello, G. (2015) · Critical Reviews in Microbiology · doi:10.3109/1040841x.2013.829415 · Cited by 73
Metadata
- Authors
- Ibekwe, A. M., & Grieve, C. M.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-03
- Volume
- 94
- Issue
- 3
- Pages
- 421-431
- ISSN
- 1364-5072 (ISSN-L)
- 1365-2672
- OpenAlex
- W2035070293
- Cited by
- 165
- References
- 0
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and quantification of Escherichia coli O157:H7 in environmental samples by real-time PCR. https://app.cochat.ai/papers/10.1046/j.1365-2672.2003.01848.x
- The paper
- Ibekwe, A. M., & Grieve, C. M. (2003). Detection and quantification of Escherichia coli O157:H7 in environmental samples by real-time PCR. Journal of Applied Microbiology. https://doi.org/10.1046/j.1365-2672.2003.01848.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.