CoChat

A study of the effectiveness of different measuring times and counting methods of human radial pulse rates

Open access
Hwu, Yueh‐Juen, Coates, Vivien E., Lin, Feng‐Yu · 2000 · Journal of Clinical Nursing
Cited by 144

The DOI matches its Crossref record.

Abstract

• The purpose of this study was to determine the reliability and validity of measuring resting radial pulse rates by the use of three measuring times: 15, 30 and 60 s; and two counting methods: one beginning with zero (0) and the other with one (1). • A two‐factor within‐subjects experimental design was used to determine the mean difference between pulse rates obtained from the radial artery, and the heart rates recorded by simultaneous electrocardiographic (ECG) recordings. The sample comprised 206 students. • Mean difference was used to calculate the extent of any differences between radial pulse rates and the rate shown by the ECG. The interaction between measuring time and counting methods was confirmed using a two‐factor within‐subjects analysis of variance. • For all types of measuring time, the counting from zero method produced a greater mean difference than the counting from one method. For all measuring times, the mean difference between radial pulse rates and rates shown by the ECG were non‐significant in the counting from one method. In other words, when the pulse rate is counted from one, the rates obtained at 15 or 30 s could be used to predict the one‐minute resting pulse rates. • The results of this study can contribute to the evidence base for this commonly used aspect of patient care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2702.2000.00350.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 144

Metadata

Authors
Hwu, Y., Coates, V. E., & Lin, F.
Venue
Journal of Clinical Nursing
Publisher
Wiley
Published
2000-01
Volume
9
Issue
1
Pages
146-152
ISSN
  • 0962-1067 (ISSN-L)
  • 1365-2702
OpenAlex
W2044918648
Cited by
144
References
0
FWCI
3.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A study of the effectiveness of different measuring times and counting methods of human radial pulse rates. https://app.cochat.ai/papers/10.1046/j.1365-2702.2000.00350.x
The paper
Hwu, Y., Coates, V. E., & Lin, F. (2000). A study of the effectiveness of different measuring times and counting methods of human radial pulse rates. Journal of Clinical Nursing. https://doi.org/10.1046/j.1365-2702.2000.00350.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.