The DOI matches its Crossref record.
Two‐photon excited lifetime imaging of autofluorescence in cells during UV A and NIR photostress
Open accessAbstract
By monitoring coenzyme autofluorescence modifications. as an indicator of cell damage. the cellular response to femtosecond near‐infrared (NIR) radiation (two‐photon absorption) was compared with exposure to low‐power UV A radiation (one‐photon absorption). Excitation radiation from a tunable Ti‐sapphire laser. focused through highnumerical‐ aperture microscope optics. provided diffractionlimited mlcrobeams of an adjustable peak power. Laser scanning NIR microscopy was used to detect spatially the intracellular distribution of fluorescent coenzymes by fluorescence intensity imaging as well as fluorescence lifetime imaging (T‐mapping). Upon the onset of UV or NIR exposure. Chinese hamster ovary cells exhibited blue/green autofluorescence witq a mean lifetime of 2·2 ns. which was attributed to NAD(P)H in mitochondria. Exposure to 365 nm radiation from a high‐pressure mercury lamp (1 m W. 300 J cm‐2 ) resulted in oxidative stress correlated with increased autofluorescence intensity. onset of nuclear fluorescence. and a fluorescence lifetime decrease. The cellular response to femtosecond NIR micro beams depended significantly on peak power. Peak powers above a threshold value of about 0·5kW (average power: 6mW). 0·55kW (7mW) and 0·8kW (lOmW) at 730nm. 760nm and 800nm. respectively. resulted in the onset of short‐lived luminescence with higher intensity (100x) than the intracellular NAD(P)H fluorescence. This luminescence. accompanied by destruction of cellular morphology. was localized and occurred in the mitochondrial region. In contrast. beams at a power of less than 0·5 kW allowed nondestructive fluorophore detection with high spatial and temporal resolution without modification of cellular redox state or cell morphology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Self-citationTwo-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Self-citationCell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Multiphoton excitation fluorescence microscopy and spectroscopy of in vivo human skin
Masters, B. R., So, P. T., & Gratton, E. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78886-6 · Cited by 439
Self-citationTwo-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Metadata
- Authors
- KÖNIG, K., SO, P. T. C., MANTULIN, W. W., TROMBERG, B. J., & GRATTON, E.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 183
- Issue
- 3
- Pages
- 197-204
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W4387989882
- Cited by
- 209
- References
- 0
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two‐photon excited lifetime imaging of autofluorescence in cells during UV A and NIR photostress. https://app.cochat.ai/papers/10.1046/j.1365-2818.1996.910650.x
- The paper
- KÖNIG, K., SO, P. T. C., MANTULIN, W. W., TROMBERG, B. J., & GRATTON, E. (1996). Two‐photon excited lifetime imaging of autofluorescence in cells during UV A and NIR photostress. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.1996.910650.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.