The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Two-Photon Excitation Fluorescence Microscopy
Abstract
▪ Abstract Two-photon fluorescence microscopy is one of the most important recent inventions in biological imaging. This technology enables noninvasive study of biological specimens in three dimensions with submicrometer resolution. Two-photon excitation of fluorophores results from the simultaneous absorption of two photons. This excitation process has a number of unique advantages, such as reduced specimen photodamage and enhanced penetration depth. It also produces higher-contrast images and is a novel method to trigger localized photochemical reactions. Two-photon microscopy continues to find an increasing number of applications in biology and medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Inoué, S., & Spring, K. R. (1997) · doi:10.1007/978-1-4615-5859-0 · Cited by 326
Cited by
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Dynamic Imaging of T Cell-Dendritic Cell Interactions in Lymph Nodes
Stoll, S., Delon, J., Brotz, T. M., & Germain, R. N. (2002) · Science · doi:10.1126/science.1071065 · Cited by 718
Spine Dynamics: Are They All the Same?
Berry, K. P., & Nedivi, E. (2017) · Neuron · doi:10.1016/j.neuron.2017.08.008 · Cited by 474
Conjugated Polymer Dots for Multiphoton Fluorescence Imaging
Wu, C., Szymanski, C., Cain, Z., & McNeill, J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja074590d · Cited by 323
Accurate Single-Molecule FRET Studies Using Multiparameter Fluorescence Detection
Sisamakis, E., Valeri, A., Kalinin, S., Rothwell, P. J., & Seidel, C. A. M. (2010) · Methods in Enzymology · doi:10.1016/s0076-6879(10)75018-7 · Cited by 268
Metadata
- Authors
- So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2000-08
- Volume
- 2
- Issue
- 1
- Pages
- 399-429
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W1943394565
- Cited by
- 1,057
- References
- 2
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-Photon Excitation Fluorescence Microscopy. https://app.cochat.ai/papers/10.1146/annurev.bioeng.2.1.399
- The paper
- So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000). Two-Photon Excitation Fluorescence Microscopy. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev.bioeng.2.1.399
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.