The DOI matches its Crossref record.
Drying cells for SEM, AFM and TEM by hexamethyldisilazane: a study on hepatic endothelial cells
Open accessAbstract
Critical point drying (CPD) is a common method of drying biological specimens for scanning electron microscopy (SEM). Drying by evaporation of hexamethyldisilazane (HMDS) has been described as a good alternative. This method, however, is infrequently used. Therefore, we reassessed HMDS drying. Cultured rat hepatic sinusoidal endothelial cells (LEC), possessing fragile fenestrae and sieve plates, were subjected to CPD and HMDS drying and evaluated in the scanning electron microscope, atomic force microscope (AFM) and transmission electron microscope (TEM). We observed no differences between the two methods regarding cellular ultrastructure. In contrast with CPD, HMDS drying takes only a few minutes, less effort, low costs for chemicals and requires no equipment. We conclude that HMDS‐dried specimens have equal quality to CPD ones. Furthermore, the method also proved useful for drying whole‐mount cells for TEM and AFM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Paek, J., Park, S. E., Lu, Q., Park, K.-T., Cho, M., Oh, J. M., Kwon, K. W., Yi, Y.-S., Song, J. W., Edelstein, H. I., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b00686 · Cited by 238
Sombke, A., Lipke, E., Michalik, P., Uhl, G., & Harzsch, S. (2015) · Journal of Comparative Neurology · doi:10.1002/cne.23741 · Cited by 144
“Scale bar 5 50 mm in A–D. 1292 The Journal of Comparative Neurology |Research in Systems Neuroscience scanning electron microscopy and even transmission electron microscopy (Braet et al., 1996).”
BackgroundHuman cells with osteogenic potential in bone tissue research
Dvorakova, J., Wiesnerova, L., Chocholata, P., Kulda, V., Landsmann, L., Cedikova, M., Kripnerova, M., Eberlova, L., & Babuska, V. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01096-w · Cited by 58
Metadata
- Authors
- Braet, F., De Zanger, R., & Wisse, E.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1997-04
- Volume
- 186
- Issue
- 1
- Pages
- 84-87
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2075718831
- Cited by
- 318
- References
- 0
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drying cells for SEM, AFM and TEM by hexamethyldisilazane: a study on hepatic endothelial cells. https://app.cochat.ai/papers/10.1046/j.1365-2818.1997.1940755.x
- The paper
- Braet, F., De Zanger, R., & Wisse, E. (1997). Drying cells for SEM, AFM and TEM by hexamethyldisilazane: a study on hepatic endothelial cells. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.1997.1940755.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.