Autofluorescence of living cells
The DOI matches its Crossref record.
Abstract
We have investigated the autofluorescence of viable mammalian cells (DU‐145 and V79) with a confocal laser scanning microscope equipped with a UV laser. Our aim was to investigate the autofluorescence dependence on different treatments in mitochondria and lysosomes by using different reagents and to improve the confocal laser scanning microscope image quality by deconvolution. The following conclusions were drawn from the results: (1) not all of the autofluorescence comes from mitochondria; (2) one can significantly affect the signal which comes from the mitochondria; (3) the other organelles involved are probably lysosomes; (4) it is harder to affect the autofluorescence signal from the lysosomes than that from the mitochondria, and (5) deconvoluted autofluorescence images provide better information than undeconvoluted ones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Stockert, J. C., Blázquez-Castro, A., Cañete, M., Horobin, R. W., & Villanueva, Á. (2012) · Acta Histochemica · doi:10.1016/j.acthis.2012.01.006 · Cited by 661
Billinton, N., & Knight, A. W. (2001) · Analytical Biochemistry · doi:10.1006/abio.2000.5006 · Cited by 499
Central dogma at the single-molecule level in living cells
Li, G.-W., & Xie, X. S. (2011) · Nature · doi:10.1038/nature10315 · Cited by 452
Autofluorescence of atmospheric bioaerosols – fluorescent biomolecules and potential interferences
Pöhlker, C., Huffman, J. A., & Pöschl, U. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-37-2012 · Cited by 394
When self-assembly meets biology: luminescent platinum complexes for imaging applications
Mauro, M., Aliprandi, A., Septiadi, D., Kehr, N. S., & De Cola, L. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60453e · Cited by 385
Besserer, A., Bécard, G., Jauneau, A., Roux, C., & Séjalon-Delmas, N. (2008) · Plant Physiology · doi:10.1104/pp.108.121400 · Cited by 298
Real-Time Fluorescence Image-Guided Oncologic Surgery
(2014) · Advances in Cancer Research · doi:10.1016/b978-0-12-411638-2.00005-7 · Cited by 163
“P A A uthor M anuscript (Andersson et al., 1998; Croce et al., 1996).”
Metadata
- Authors
- Andersson, Baechi, Hoechl, & Richter
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1998-07
- Volume
- 191
- Issue
- 1
- Pages
- 1-7
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W1606010310
- Cited by
- 199
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.