Minimal compression of ultrathin sections with use of an oscillating diamond knife
The DOI matches its Crossref record.
Abstract
With the aim to minimize compression artefacts in ultrathin sections, coincident with the stroke direction, we have invented an oscillating diamond knife. Results and theoretical considerations explaining its function are discussed. During conventional ultrathin sectioning the resultant compression is in the order of 20–35% of section height. This holds true for sections of samples embedded into Lowicryl HM20 and of the polymer polystyrene, cut with a 45° diamond knife and floated on water. The oscillating knife reduces this compression almost completely. It consists of a diamond knife on which a low voltage piezoelectric translator (piezo) is mounted, which oscillates when the piezo is driven by an alternating voltage source. No additional cutting artefacts were observed in the micrographs when they were compared with sections produced without oscillating the knife.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Serial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure
Denk, W., & Horstmann, H. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020329 · Cited by 1,644
“To suppress chatter and to achieve thinner sectioning, we have begun to use the oscillating-knife technique (Studer and Gnaegi 2000) (see Figures 5 and S2– S4).”
Connectomic reconstruction of the inner plexiform layer in the mouse retina
Helmstaedter, M., Briggman, K. L., Turaga, S. C., Jain, V., Seung, H. S., & Denk, W. (2013) · Nature · doi:10.1038/nature12346 · Cited by 997
(2006) · doi:10.1007/978-0-387-69008-7 · Cited by 357
Volume scanning electron microscopy for imaging biological ultrastructure
Titze, B., & Genoud, C. (2016) · Biology of the Cell · doi:10.1111/boc.201600024 · Cited by 287
Ultrastructurally smooth thick partitioning and volume stitching for large-scale connectomics
Hayworth, K. J., Xu, C. S., Lu, Z., Knott, G. W., Fetter, R. D., Tapia, J. C., Lichtman, J. W., & Hess, H. F. (2015) · Nature Methods · doi:10.1038/nmeth.3292 · Cited by 144
Metadata
- Authors
- Studer, & Gnaegi
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2000-01
- Volume
- 197
- Issue
- 1
- Pages
- 94-100
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2153454039
- Cited by
- 86
- References
- 0
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimal compression of ultrathin sections with use of an oscillating diamond knife. https://app.cochat.ai/papers/10.1046/j.1365-2818.2000.00638.x
- The paper
- Studer, & Gnaegi. (2000). Minimal compression of ultrathin sections with use of an oscillating diamond knife. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.2000.00638.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.