The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative phase‐amplitude microscopy I: optical microscopy
Abstract
Summary: In this paper, the application of a new optical microscopy method (quantitative phase‐amplitude microscopy) to biological imaging is explored, and the issue of resolution and image quality is examined. The paper begins by presenting a theoretical analysis of the method using the optical transfer function formalism of Streibl (1985). The effect of coherence on the formation of the phase image is explored, and it is shown that the resolution of the method is not compromised over that of a conventional bright‐field image. It is shown that the signal‐to‐noise ratio of the phase recovery, however, does depend on the degree of coherence in the illumination. Streibl (1985) notes that partially coherent image formation is a non‐linear process because of the intermingling of amplitude and phase information. The work presented here shows that the quantitative phase‐amplitude microscopy method acts to linearize the image formation process, and that the phase and amplitude information is properly described using a transfer function analysis. The theoretical conclusions are tested experimentally using an optical microscope and the theoretical deductions are confirmed. Samples for microscopy influence both the phase and amplitude of the light wave and it is demonstrated that the new phase recovery method can separate the amplitude and phase information, something not possible using traditional phase microscopy. In the case of a coherent wave, knowledge of the phase and amplitude constitutes complete information that can be used to emulate other forms of microscopy. This capacity is demonstrated by recovering the phase of a sample and using the data to emulate a differential interference contrast image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase contrast, a new method for the microscopic observation of transparent objects
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80035-x · Cited by 1,068
Cited by
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Coherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Self-citationComputational illumination for high-speed in vitro Fourier ptychographic microscopy
Tian, L., Liu, Z., Yeh, L.-H., Chen, M., Zhong, J., & Waller, L. (2015) · Optica · doi:10.1364/optica.2.000904 · Cited by 317
Linear phase imaging using differential interference contrast microscopy
Arnison, M. R., Larkin, K. G., Sheppard, C. J. R., Smith, N. I., & Cogswell, C. J. (2004) · Journal of Microscopy · doi:10.1111/j.0022-2720.2004.01293.x · Cited by 271
Practical application of microsphere samples for benchmarking a quantitative phase imaging system
Kwee, E., Peterson, A., Halter, M., & Elliott, J. (2021) · Cytometry Part A · doi:10.1002/cyto.a.24291 · Cited by 9
“The importance of the ratio of the illumination numerical aperture (NA) to the microscope objective NA has been highlighted when using the transport of intensity QPI approach [22].”
BackgroundMethodResultInfluential
Metadata
- Authors
- Barone‐Nugent, E. D., Barty, A., & Nugent, K. A.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2002-06
- Volume
- 206
- Issue
- 3
- Pages
- 194-203
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W1517212945
- Cited by
- 190
- References
- 1
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative phase‐amplitude microscopy I: optical microscopy. https://app.cochat.ai/papers/10.1046/j.1365-2818.2002.01027.x
- The paper
- Barone‐Nugent, E. D., Barty, A., & Nugent, K. A. (2002). Quantitative phase‐amplitude microscopy I: optical microscopy. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.2002.01027.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.