Fluorescence lifetime imaging in scanning microscopes: acquisition speed, photon economy and lifetime resolution
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Summary: In this paper a detailed discussion is presented of the factors that affect the fluorescence lifetime imaging performance of a scanning microscope equipped with a single photon counting based, two‐ to eight‐channel, time‐gated detection system. In particular we discuss the sensitivity, lifetime resolution, acquisition speed, and the shortest lifetimes that can be measured. Detection systems equipped with four to eight time‐gates are significantly more sensitive than the two time‐gate system. Only minor sensitivity differences were found between systems with four or more time‐gates. Experiments confirm that the lifetime resolution is dominated by photon statistics. The time response of the detector determines the shortest lifetimes that can be resolved; about 25 ps for fast MCP‐PMTs and 300–400 ps for other detectors. The maximum count rate of fast MCP‐PMTs, however, is 10–100 times lower than that of fast PMTs. Therefore, the acquisition speed with MCP‐PMT based systems is limited. With a fast PMT operated close to its maximum count rate we were able to record a fluorescence lifetime image of a beating myocyte in less than one second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Excited State Lifetime Measurements
(1983) · Elsevier eBooks · doi:10.1016/b978-0-12-208920-6.x5001-0 · Cited by 638 · cited 1×
“In TCSPC (lifetime spectroscopy) experiments that require the best possible lifetime resolution and reproducibility, the pile-up should be less than 1% (Demas, 1983; O’Connor & Phillips, 1984).”
BackgroundGadella, T. W. J., Jovin, T. M., & Clegg, R. M. (1993) · Biophysical Chemistry · doi:10.1016/0301-4622(93)85012-7 · Cited by 375 · cited 1×
“Fluorescence lifetime imaging can be implemented using frequency domain methods (Gadella et al., 1993; Lakowicz & Berndt, 1991, Morgan et al., 1990) and timedomain methods (Bugiel et al., 1989; Buurman et al., 1992; Schneckenburger & Konig, 1992; Wang et al., 1991).”
MethodHow many photons are necessary for fluorescence-lifetime measurements?
Köllner, M., & Wolfrum, J. (1992) · Chemical Physics Letters · doi:10.1016/0009-2614(92)87068-z · Cited by 366 · cited 1×
“Theoretical calculations (Kollner & Wolfrum, 1992) and computer simulations (Gerritsen et al., 1996; de Grauw & Gerritsen, 2001) revealed that at the optimum gate width a twogate system requires only 225 detected photons for an accuracy of 10% in the fluorescence lifetime.”
BackgroundBallew, R. M., & Demas, J. N. (1989) · Analytical Chemistry · doi:10.1021/ac00176a007 · Cited by 262 · cited 2×
“For the two-gate system Ballew & Demas (1989) demonstrated that the optimum gate width in the case of equal gate widths amounts to 2.5 times the fluorescence lifetime.”
BackgroundInfluentialLifetime-selective fluorescence imaging using an rf phase-sensitive camera
Lakowicz, J. R., & Berndt, K. W. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142413 · Cited by 257 · cited 1×
“Fluorescence lifetime imaging can be implemented using frequency domain methods (Gadella et al., 1993; Lakowicz & Berndt, 1991, Morgan et al., 1990) and timedomain methods (Bugiel et al., 1989; Buurman et al., 1992; Schneckenburger & Konig, 1992; Wang et al., 1991).”
MethodElangovan, M., Day, R. N., & Periasamy, A. (2002) · Journal of Microscopy · doi:10.1046/j.0022-2720.2001.00984.x · Cited by 232 · cited 1×
“Multi-exponential decays can be already measured using four (Elangovan et al., 2002) or eight (de Grauw & Gerritsen, 2001) gates.”
MethodFluorescence lifetime imaging using a confocal laser scanning microscope
Buurman, E. P., Sanders, R., Draaijer, A., Gerritsen, H. C., van Veen, J. J. F., Houpt, P. M., & Levine, Y. K. (1992) · Scanning · doi:10.1002/sca.4950140305 · Cited by 190 · cited 2×
“We have implemented time-gated detection schemes in both a confocal microscope (Buurman et al., 1992) and in a multiphoton excitation microscope (Sytsma et al., 1998).”
MethodSelf-citationFluorescence lifetime imaging of receptor tyrosine kinase activity in cells
Wouters, F. S., & Bastiaens, P. I. H. (1999) · Current Biology · doi:10.1016/s0960-9822(99)80484-9 · Cited by 188
A Two-Dimensional Fluorescence Lifetime Imaging System Using a Gated Image Intensifier
Wang, X. F., Uchida, T., Coleman, D. M., & Minami, S. (1991) · Applied Spectroscopy · doi:10.1366/0003702914337182 · Cited by 175 · cited 1×
“Fluorescence lifetime imaging can be implemented using frequency domain methods (Gadella et al., 1993; Lakowicz & Berndt, 1991, Morgan et al., 1990) and timedomain methods (Bugiel et al., 1989; Buurman et al., 1992; Schneckenburger & Konig, 1992; Wang et al., 1991).”
MethodFluorescence lifetime imaging of oxygen in living cells
Gerritsen, H. C., Sanders, R., Draaijer, A., İnce, C., & Levine, Y. K. (1997) · Journal of Fluorescence · doi:10.1007/bf02764572 · Cited by 171
Self-citationTime‐gated fluorescence lifetime imaging and microvolume spectroscopy using two‐photon excitation
Sytsma, Vroom, Grauw, D., & Gerritsen (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00351.x · Cited by 138 · cited 5×
“We have implemented time-gated detection schemes in both a confocal microscope (Buurman et al., 1992) and in a multiphoton excitation microscope (Sytsma et al., 1998).”
BackgroundMethodInfluentialMultiple Time-Gate Module for Fluorescence Lifetime Imaging
de Grauw, C. J., & Gerritsen, H. C. (2001) · Applied Spectroscopy · doi:10.1366/0003702011952587 · Cited by 102 · cited 6×
“We demonstrated that this accuracy could indeed be realized in practice, thus proving that the accuracy is determined by photon statistics alone (Sytsma et al., 1998; de Grauw & Gerritsen, 2001).”
BackgroundMethodInfluentialSelf-citationFluorescence decay kinetics and imaging of NAD(P)H and flavins as metabolic indicators
Schneckenburger, H., & Koenig, K. (1992) · Optical Engineering · doi:10.1117/12.57704 · Cited by 92 · cited 1×
“Fluorescence lifetime imaging can be implemented using frequency domain methods (Gadella et al., 1993; Lakowicz & Berndt, 1991, Morgan et al., 1990) and timedomain methods (Bugiel et al., 1989; Buurman et al., 1992; Schneckenburger & Konig, 1992; Wang et al., 1991).”
MethodFluorescence Lifetime Imaging, a New Tool in Confocal Microscopy
Draaijer, A., Sanders, R., & Gerritsen, H. C. (1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6_31 · Cited by 83 · cited 1×
“Using the fluorescence lifetime of a fluorescent molecule as a contrast mechanism can further enhance the potential of fluorescence microscopy (Draaijer et al., 1995).”
BackgroundSelf-citationCa2+ transients in cardiac myocytes measured with high and low affinity Ca2+ indicators
Berlin, J. R., & Konishi, M. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81211-6 · Cited by 78 · cited 1×
“The myocytes spontaneously beat at rates of 0.5–2 Hz at 37 °C and the beating was accompanied by large Ca2+ fluxes (Berlin & Konishi, 1993).”
BackgroundInfluential
Cited by
Jares-Erijman, E. A., & Jovin, T. M. (2003) · Nature Biotechnology · doi:10.1038/nbt896 · Cited by 1,824
The Phasor Approach to Fluorescence Lifetime Imaging Analysis
Digman, M. A., Caiolfa, V. R., Zamai, M., & Gratton, E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120154 · Cited by 1,145
Yao, J., Yang, M., & Duan, Y. (2014) · Chemical Reviews · doi:10.1021/cr200359p · Cited by 944
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Metadata
- Authors
- Gerritsen, H. C., Asselbergs, M. A. H., Agronskaia, A. V., & Van Sark, W. G. J. H. M.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2002-06
- Volume
- 206
- Issue
- 3
- Pages
- 218-224
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W1548141905
- Cited by
- 221
- References
- 18
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.