The DOI matches its Crossref record.
Lifetime-selective fluorescence imaging using an rf phase-sensitive camera
Abstract
We report the creation of two-dimensional fluorescence lifetime images, based on a sinusoidally modulated image intensifier that is operated as a radio-frequency phase-sensitive camera, synchronized to a mode-locked and cavity dumped picosecond dye laser. By combining the image intensifier with a CCD camera and applying digital image processing, lifetime-selective signal suppression can be realized even for fluorophores with comparable lifetimes. This phase-sensitive technique can be used to create fluorescence lifetime images, that is, images in which the contrast is based upon the fluorescence lifetimes rather than upon local probe concentration and/or intensity. Because the lifetimes of many dyes are sensitive to the chemical environments surrounding the fluorophore, fluorescence lifetime imaging (FLIM) can reveal the local chemical composition and properties of the molecular environment that surrounds the fluorophore. As an example we created images of rhodamine 6G (4 ns) and rhodamine B (1.5 ns) solutions in which the difference in lifetimes results in 100% contrast, whereas the total fluorescence intensity is similar. In order to estimate the time resolution obtainable with our phase-sensitive imaging setup, we also performed measurements using distance-selective suppression of optical signals backscattered from laser-illuminated targets. In these studies, we have created distance-selective images with a resolution of 3.75 cm, which corresponds to a lifetime resolution of 0.25 ns for fast-decaying fluorophores. Since we observed nearly 100% contrast for this 0.25 ns difference, still smaller distances and/or lifetime differences could be observed, which seems to imply some advantages of phase fluorometric lifetime imaging. Using these same intensifiers in the pulse-gating mode one expects a typical 5 ns gating time, which result in a distance resolution of only 75 cm. The distance-selective imaging principle has the potential for manifold applications related to robotics, construction, and even to spacecraft maneuvering. Fluorescence lifetime imaging, in combination with fluorescence microscopy, can have numerous applications to biochemistry, biophysics, and cell physiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Imaging Sites of Receptor Dephosphorylation by PTP1B on the Surface of the Endoplasmic Reticulum
Haj, F. G., Verveer, P. J., Squire, A., Neel, B. G., & Bastiaens, P. I. H. (2002) · Science · doi:10.1126/science.1067566 · Cited by 434
Gadella, T. W. J., Jovin, T. M., & Clegg, R. M. (1993) · Biophysical Chemistry · doi:10.1016/0301-4622(93)85012-7 · Cited by 375
Quantitative Imaging of Lateral ErbB1 Receptor Signal Propagation in the Plasma Membrane
Verveer, P. J., Wouters, F. S., Reynolds, A. R., & Bastiaens, P. I. H. (2000) · Science · doi:10.1126/science.290.5496.1567 · Cited by 351
Metadata
- Authors
- Lakowicz, J. R., & Berndt, K. W.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1991-07-01
- Volume
- 62
- Issue
- 7
- Pages
- 1727-1734
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2024108719
- Cited by
- 257
- References
- 0
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lifetime-selective fluorescence imaging using an rf phase-sensitive camera. https://app.cochat.ai/papers/10.1063/1.1142413
- The paper
- Lakowicz, J. R., & Berndt, K. W. (1991). Lifetime-selective fluorescence imaging using an rf phase-sensitive camera. Review of Scientific Instruments. https://doi.org/10.1063/1.1142413
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.