CoChat

Co‐localization analysis of complex formation among membrane proteins by computerized fluorescence microscopy: application to immunofluorescence co‐patching studies

Lachmanovich, E., Shvartsman, D. E., Malka, Y., Botvin, C., Henis, Y. I., Weiss, A. M. · 2003 · Journal of Microscopy
Cited by 140

The DOI matches its Crossref record.

Abstract

Summary: Fluorescence imaging of two independently labelled proteins is commonly used to determine their co‐localization in cells. Antibody‐mediated crosslinking can mediate the patching of such proteins at the cell surface, and their co‐localization can serve to determine complex formation among them. However, manual analysis of such studies is both tedious and subjective. Here we present a digital co‐localization analysis that is independent of the fluorescence intensity, is highly consistent and reproducible between observers, and dramatically reduces the analysis time. The approach presented is based on a segmentation procedure that creates binary objects, and then determines whether objects belonging to two different groups (e.g. green‐ and red‐labelled) are co‐localized. Two methods are used to determine co‐localization. The ‘overlap’ analysis defines two objects as co‐localized if the centre of mass of one falls within the area of the other. The ‘nearest‐neighbour distance’ analysis considers two objects as co‐localized if their centres are within a threshold distance determined by the imaging modality. To test the significance of the results, the analysis of the actual images is tested against randomized images generated by a method that creates images with uncorrelated distributions of objects from the two groups. The applicability of the algorithms presented to study protein interactions in live cells is demonstrated by co‐patching studies on influenza haemagglutinin mutants that do or do not associate into mutual oligomers at the cell surface via binding to AP‐2 adaptor complexes. The approach presented is potentially applicable to studies of co‐localization by other methods (e.g. electron microscopy), and the nearest‐neighbour distance method can also be adapted to study phenomena of correlated placement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2818.2003.01239.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 140

Metadata

Authors
Lachmanovich, E., Shvartsman, D. E., Malka, Y., Botvin, C., Henis, Y. I., & Weiss, A. M.
Venue
Journal of Microscopy
Publisher
Wiley
Published
2003-11
Volume
212
Issue
2
Pages
122-131
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2100726540
Cited by
140
References
0
FWCI
0.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Co‐localization analysis of complex formation among membrane proteins by computerized fluorescence microscopy: application to immunofluorescence co‐patching studies. https://app.cochat.ai/papers/10.1046/j.1365-2818.2003.01239.x
The paper
Lachmanovich, E., Shvartsman, D. E., Malka, Y., Botvin, C., Henis, Y. I., & Weiss, A. M. (2003). Co‐localization analysis of complex formation among membrane proteins by computerized fluorescence microscopy: application to immunofluorescence co‐patching studies. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.2003.01239.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.